ETE DV250P6S6 is a 250 VA single-phase dual-input-voltage industrial control transformer with selectable 240 V AC or 415 V AC primary connections, a 24 V AC secondary output, Class E insulation, 8% voltage regulation and EPH 3 or EPN 2 enclosure references.
£45.38
The ETE DV250P6S6 is a versatile 250 VA single-phase industrial control transformer designed to convert either a 240 V AC or 415 V AC primary supply into a nominal 24 V AC secondary output. Manufactured by Eastern Transformers & Equipment (ETE), this model belongs to the ETE DV dual-input-voltage stock control transformer range, developed for electrical panel builders, machinery manufacturers and industrial automation applications requiring a dependable low-voltage AC control supply.
The DV250P6S6 features a 0/240/415 V primary terminal configuration, allowing installers to select the appropriate input connection for the available electrical supply. Its 0/24 V secondary terminals provide a single nominal 24 V AC output, making it suitable for compatible contactors, relays, control devices and auxiliary equipment. This dual-input design offers flexibility for machinery and electrical panels intended for different industrial supply arrangements.
With a rated apparent power of 250 VA, Class E insulation and 8% voltage regulation, the ETE DV250P6S6 is designed for reliable operation within appropriately specified industrial control circuits. Its continuous-rated construction, IP20 touch-proof terminals, Class H varnish impregnation and core earth connection provide practical features for professional electrical installations.
Measuring 120 × 88 × 120 mm and weighing 3.9 kg, the DV250P6S6 offers a compact solution for electrical control cabinets and machinery panels. The specified EPH 3 or EPN 2 enclosure references provide options for installations requiring additional physical protection.
The ETE DV250P6S6 is designed for industrial electrical systems where the available primary supply may be either 240 V AC or 415 V AC. Its tapped primary winding features 0/240/415 V terminals, allowing the correct input connection to be selected during installation. When connected to the matching primary voltage, the transformer provides a nominal 24 V AC secondary output through its 0/24 V secondary terminals.
This dual-input configuration is particularly useful for OEM machinery manufacturers and electrical panel builders producing equipment for different industrial electrical supplies. The DV250P6S6 can accommodate either supported primary voltage without requiring a separate transformer model for each supply arrangement. The primary terminals must always be connected according to the available voltage and the manufacturer's wiring instructions; the two input voltage options are alternatives, not separate supplies to be connected simultaneously.
The transformer's 250 VA rating provides a calculated full-load secondary current of approximately 10.42 A at its nominal 24 V AC output. This figure is derived by dividing the rated apparent power by the secondary voltage. When selecting a transformer, engineers should consider the total apparent power of connected equipment, permissible voltage variation, operating conditions and any short-duration inrush current requirements, particularly when supplying electromagnetic contactors or multiple control devices.
The specified 8% voltage regulation describes the change in secondary voltage between no-load and rated-load conditions under the applicable test conditions. This characteristic should be considered when supplying control equipment with defined operating voltage tolerances. Although the transformer provides a nominal 24 V AC output, the actual secondary voltage can vary with supply voltage and connected load.
The DV250P6S6 incorporates Class E insulation, IP20 touch-proof terminals, Class H varnish impregnation and a dedicated core earth connection. For installations requiring additional physical protection, the specified enclosure references are EPH 3 or EPN 2. Correct primary and secondary circuit protection, protective earthing, ventilation, conductor sizing and suitable mounting arrangements remain essential for safe and dependable operation.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 250 VA | |
|---|---|---|
| Primary Voltage | 0/240/415V | |
| Secondary Voltage | 0/24V | |
| Phase | Single Phase | |
| Manufacturer | Eastern Transformers & Equipment (ETE) | |
| Series | DV Dual-Input-Voltage Stock Control Transformer Range | |
| Model | DV250P6S6 | |
| Product type | Industrial control circuit transformer | |
| Transformer configuration | Dual-input-voltage primary, single-voltage secondary | |
| Number of phases | Single-phase | |
| Rated apparent power | 250 VA | |
| Primary voltage options | 240 V AC or 415 V AC | |
| Primary terminals | 0/240/415 V | |
| Secondary voltage | 24 V AC | |
| Secondary terminals | 0/24 V | |
| Output connection | 24 V | |
| Rated frequency | 50/60 Hz | |
| Duty rating | Continuous | |
| Insulation class | Class E | |
| Varnish impregnation | Class H | |
| Voltage regulation | 8% | |
| Terminal protection | IP20 touch-proof terminals | |
| Core earthing | Dedicated core earth connection | |
| Ambient operating temperature | −10 °C to +35 °C | |
| Design standard | EN 61558-1 | |
| Calculated full-load secondary current | Approximately 10.42 A | |
| Calculated ideal primary current at 240 V AC | Approximately 1.04 A, excluding losses | |
| Calculated ideal primary current at 415 V AC | Approximately 0.60 A, excluding losses | |
| Length | 120 mm | |
| Width | 88 mm | |
| Height | 120 mm | |
| Dimensions (L × W × H) | 120 × 88 × 120 mm | |
| Weight | 3.9 kg | |
| Enclosure reference | EPH 3 or EPN 2 | |
| Installation type | Electrical control panel or suitable enclosure mounting | |
| Product range reference | ETE Stock Control Transformer Range, March 2026 |
The ETE DV250P6S6 is a 250 VA single-phase dual-input-voltage control transformer designed to provide a nominal 24 V AC output from either a 240 V AC or 415 V AC primary supply. It is suitable for compatible industrial machinery control circuits and auxiliary electrical equipment.
Dual-input voltage means the transformer has 0/240/415 V primary terminals, allowing it to be connected for either a 240 V AC or 415 V AC supply. The correct primary terminal connection must be selected for the available supply voltage.
The ETE DV250P6S6 has a rated apparent power of 250 VA. Connected equipment must remain within this rating and the transformer's applicable operating limits.
The transformer has 0/240/415 V primary terminals and 0/24 V secondary terminals. When connected correctly to either supported primary voltage, it provides a nominal 24 V AC output.
Based on its 250 VA rating and 24 V AC secondary voltage, the calculated full-load secondary current is approximately 10.42 A. Actual transformer selection must also account for connected load characteristics and any inrush requirements.
The DV250P6S6 uses a Class E insulation system designed in accordance with EN 61558-1. Its windings also feature protective Class H varnish impregnation.
The transformer measures 120 mm long, 88 mm wide and 120 mm high, with a specified weight of 3.9 kg.
The ETE DV250P6S6 has a specified 8% voltage regulation. This should be considered when assessing the secondary voltage requirements of connected control equipment under changing load conditions.
The specified enclosure references are EPH 3 or EPN 2. Enclosure selection should account for the installation environment, transformer dimensions, ventilation requirements and applicable electrical safety regulations.
Yes. The DV250P6S6 is designed for industrial control applications and can be installed within a suitably designed electrical control panel or enclosure, with appropriate mounting, ventilation, circuit protection and protective earthing.
No. The ETE DV250P6S6 provides a nominal 24 V AC secondary output, not 24 V DC. Equipment requiring direct current needs a suitable DC power supply or appropriately rated rectification and conditioning equipment.
No. The 0/240/415 V primary terminals provide alternative connections for the supported input voltages. The transformer must be connected using the correct primary terminals for the available supply, following the manufacturer's instructions. It is not designed to combine two independent primary supplies.
ETE DV dual-input-voltage control transformers offer practical flexibility for industrial electrical installations. With its selectable 240 V AC or 415 V AC primary connection, 24 V AC secondary output, 250 VA rating, Class E insulation, 8% voltage regulation and robust industrial construction, the ETE DV250P6S6 provides a dependable solution for OEM machinery, electrical control panels and industrial automation applications requiring a dedicated 24 V AC control supply.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.