Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ETE DV200P6S4 is a 200 VA single-phase dual-input-voltage control transformer with selectable 240 V or 415 V AC primary connections, a 110 V AC secondary output, Class E insulation, 10% voltage regulation and EPH 2 or EPN 1 enclosure compatibility for industrial control applications.
£37.43
The ETE DV200P6S4 is a reliable 200 VA single-phase industrial control transformer designed to provide a 110 V AC secondary output from either a 240 V AC or 415 V AC primary supply. Manufactured by Eastern Transformers & Equipment (ETE), this transformer belongs to the established DV dual-input-voltage control transformer series, developed for industrial electrical control panels, machine building and automation systems requiring flexible input voltage selection.
The DV200P6S4 features a tapped primary winding with 0/240/415 V terminals, allowing installers to select the appropriate connection for the available supply voltage. Its 0/110 V secondary terminals provide a dedicated 110 V AC output for compatible contactors, control relays, solenoids, signalling devices and other industrial control equipment. The dual-input arrangement makes this transformer particularly useful for panel builders and OEM machinery manufacturers working with different electrical supply configurations.
With a rated apparent power of 200 VA, Class E insulation and 10% voltage regulation, the DV200P6S4 offers dependable voltage transformation in a compact industrial design. Measuring 96 × 104 × 103 mm and weighing 3.5 kg, it is suitable for integration into electrical control cabinets. Compatible enclosure references are ETE EPH 2 or EPN 1, providing additional installation flexibility where an enclosed transformer arrangement is required.
The ETE DV200P6S4 provides a practical solution for industrial applications requiring a dedicated 110 V AC control supply where the available primary voltage may be either 240 V AC or 415 V AC. Its dual-input-voltage arrangement enables the correct primary connection to be selected during installation, allowing one transformer model to accommodate different electrical supply configurations.
For a 240 V AC input, the transformer uses its designated 0/240 V primary terminals. For a 415 V AC input, the designated 0/415 V primary terminals are used. Both arrangements provide a nominal 110 V AC secondary output. The primary connections are alternative voltage selections and must not be energised simultaneously from separate electrical supplies.
The 200 VA continuous apparent power rating corresponds to a calculated nominal full-load secondary current of approximately 1.82 A at 110 V AC. This capacity makes the transformer suitable for appropriately sized industrial control circuits, including compatible contactor coils, electromagnetic relays and signalling equipment. Where contactors or solenoids have significant energisation demands, their inrush VA requirements must also be considered when selecting a transformer.
The specified 10% voltage regulation describes the variation in secondary voltage between no-load and rated-load conditions. This characteristic should be considered when designing circuits with voltage-sensitive control components or loads that change during machinery operation. The ETE DV200 transformer size also has published contactor inrush selection figures of 350 VA at 95% secondary voltage and 600 VA at 90% secondary voltage, providing useful additional guidance when assessing electromagnetic control loads.
Industrial durability is supported by the transformer's Class E insulation system, Class H varnish impregnation, IP20 touch-proof terminals and protective core earth connection. The design follows EN 61558-1 and is intended for continuous control circuit operation within its specified electrical and environmental limits.
For installation within electrical control cabinets, the DV200P6S4 measures 96 × 104 × 103 mm and can be accommodated using the specified EPH 2 or EPN 1 enclosure references. Suitable primary and secondary circuit protection, conductor sizing, protective earthing and ventilation should be incorporated into the installation.
Although the transformer may be connected across two suitable phases of a three-phase system where the phase-to-phase voltage is 415 V AC, the DV200P6S4 remains a single-phase transformer. Its 0/110 V secondary winding provides a nominal 110 V AC output and should not be confused with a centre-tapped 55/0/55 V supply used in certain construction-site applications.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 200 VA | |
|---|---|---|
| Primary Voltage | 0/240/415V | |
| Secondary Voltage | 0/110V | |
| Phase | Single Phase | |
| Manufacturer | Eastern Transformers & Equipment (ETE) | |
| Brand | ETE | |
| Series | DV Dual-Input-Voltage Control Transformers | |
| Manufacturer part number | DV200P6S4 | |
| Product type | Industrial control circuit transformer | |
| Transformer configuration | Dual-input-voltage primary with single-voltage secondary | |
| Number of phases | Single-phase | |
| Rated apparent power | 200 VA | |
| Primary voltage options | 240 V AC or 415 V AC | |
| Primary terminals | 0/240/415 V | |
| Secondary voltage | 110 V AC | |
| Secondary terminals | 0/110 V | |
| Output connection | 110 V AC | |
| Calculated nominal full-load secondary current | Approximately 1.82 A | |
| Calculated nominal primary current at 240 V | Approximately 0.83 A, based on rated apparent power | |
| Calculated nominal primary current at 415 V | Approximately 0.48 A, based on rated apparent power | |
| Rated frequency | 50/60 Hz | |
| Duty rating | Continuous | |
| Insulation class | Class E | |
| Varnish impregnation | Class H | |
| Voltage regulation | 10% | |
| Terminal protection | IP20 touch-proof terminals | |
| Earthing provision | Core earth connection | |
| Ambient operating temperature | −10 to +35 °C | |
| Design standard | EN 61558-1 | |
| Length | 96 mm | |
| Width | 104 mm | |
| Height | 103 mm | |
| Dimensions (L × W × H) | 96 × 104 × 103 mm | |
| Weight | 3.5 kg | |
| Compatible enclosure references | EPH 2 or EPN 1 | |
| Typical installation | Industrial electrical control panels and machinery cabinets | |
| Country of manufacture | United Kingdom | |
| Product range reference | ETE Stock Control Transformer Range, March 2026 |
The ETE DV200P6S4 is a 200 VA single-phase industrial control transformer designed to provide a nominal 110 V AC output from either a 240 V AC or 415 V AC primary supply for machinery, automation equipment and electrical control panels.
Dual-input-voltage means the transformer has primary connections for two alternative supply voltages: 240 V AC and 415 V AC. The appropriate primary terminals are selected to match the available supply, while the secondary output remains nominally 110 V AC.
The transformer has 0/240/415 V primary terminals and 0/110 V secondary terminals. The installer must use the correct primary voltage tap for the available electrical supply.
The DV200P6S4 has a rated apparent power of 200 VA and is designed for continuous control circuit operation within its specified rating.
At its rated output of 200 VA and 110 V AC, the calculated nominal full-load secondary current is approximately 1.82 A.
Yes. Where a suitable 415 V AC phase-to-phase supply is available, the transformer can be connected using its designated 0/415 V primary terminals. The DV200P6S4 itself remains a single-phase transformer and must be installed with appropriate electrical protection.
The transformer provides a nominal 110 V AC secondary output. It does not incorporate a rectifier or regulated DC power supply, so equipment requiring 110 V DC needs suitable additional power conversion equipment.
The DV200P6S4 is specified with a 0/110 V secondary winding, rather than a 55/0/55 V centre-tapped secondary. It should not be assumed to provide a centre-tapped output for construction-site equipment.
The transformer has a Class E insulation system and a specified 10% voltage regulation. Its construction also incorporates Class H varnish impregnation.
The transformer measures 96 mm long × 104 mm wide × 103 mm high and weighs 3.5 kg.
The specified compatible enclosure references are ETE EPH 2 or EPN 1. Final selection should account for installation conditions, ventilation and the required enclosure protection.
The ETE DV range offers a DIN rail mounting option for smaller transformers up to 150 VA. The DV200P6S4 is a 200 VA model, so DIN rail compatibility should not be assumed; use the appropriate mounting arrangement specified for this transformer.
Yes. The DV200P6S4 incorporates IP20 touch-proof terminals and a core earth connection for protective earthing within an appropriately designed electrical installation.
ETE lists contactor inrush selection figures of 350 VA at 95% secondary voltage and 600 VA at 90% secondary voltage for the DV200 transformer size. These figures assist transformer selection for control circuits containing contactors and other electromagnetic loads.
The DV200P6S4 is designed for 50/60 Hz operation with an ambient temperature range of −10 to +35 °C.
No. The 240 V and 415 V primary connections are alternative voltage selections. The installer must use the correct terminals for the available supply and must not connect independent supplies to both primary voltage taps simultaneously.
ETE DV dual-input-voltage control transformers provide flexible and dependable voltage transformation for industrial electrical installations. With its 200 VA rating, selectable 240/415 V primary connections, 110 V AC output and robust Class E insulation system, the DV200P6S4 is a practical choice for panel builders, machinery manufacturers and maintenance engineers requiring reliable control power across different supply configurations.