ETE DV150P6S4 is a 150 VA single-phase dual-input-voltage industrial control transformer with selectable 240 V AC or 415 V AC primary connections, a 110 V AC secondary output, Class E insulation, 10% voltage regulation and EPH 2 or EPN 1 enclosure references.
£33.38
The ETE DV150P6S4 is a versatile 150 VA single-phase industrial control transformer designed to provide a nominal 110 V AC secondary output from either a 240 V AC or 415 V AC primary supply. Manufactured by Eastern Transformers & Equipment (ETE), this transformer belongs to the established ETE DV dual-input-voltage stock control transformer range, developed for electrical panel builders, machinery manufacturers and industrial automation applications requiring flexible primary voltage connections.
Unlike a single-input-voltage transformer, the DV150P6S4 features a 0/240/415 V primary terminal arrangement, allowing installers to select the appropriate primary connection for the available supply. Its 0/110 V secondary terminals provide a single nominal 110 V AC output, making it suitable for machinery and electrical control systems designed around a 110 V AC control supply.
The DV150P6S4 combines a 150 VA apparent power rating with Class E insulation, 10% voltage regulation and industrial construction. Its dimensions of 96 × 87 × 103 mm and specified weight of 2.8 kg make it a practical option for electrical control panels where installation space must be considered.
With specified EPH 2 or EPN 1 enclosure references, the ETE DV150P6S4 offers flexibility for both panel-mounted and appropriately enclosed installations. Its dual-input arrangement is particularly useful for OEMs and panel builders working with equipment intended for different industrial supply voltages.
The ETE DV150P6S4 is designed for industrial electrical systems where the available primary supply may be either 240 V AC or 415 V AC. Its tapped primary winding provides 0/240/415 V terminals, enabling the correct primary connection to be selected during installation. When connected to the appropriate input voltage, the transformer provides a nominal 110 V AC secondary output through its 0/110 V secondary terminals.
This dual-input configuration is useful for machinery manufacturers, OEMs and electrical panel builders producing equipment for different supply arrangements. A single DV150P6S4 model can accommodate either supported primary voltage, reducing the need to specify separate transformer variants for 240 V AC and 415 V AC installations. The primary terminals must always be connected according to the actual supply voltage and the manufacturer's wiring instructions.
With a 150 VA rating, the transformer provides a calculated full-load secondary current of approximately 1.36 A at its nominal 110 V AC output. This figure is calculated by dividing the rated apparent power by the secondary voltage. Transformer sizing should also consider the total connected load, power factor, switching characteristics and short-duration inrush requirements, particularly when supplying contactors or other electromagnetic devices.
The specified 10% voltage regulation is an important consideration when evaluating secondary voltage variation under different load conditions. Connected equipment must be capable of operating within the actual secondary voltage range expected in service, rather than assuming the output will remain exactly 110 V AC under all conditions.
The DV150P6S4 features a Class E insulation system, IP20 touch-proof terminals, Class H varnish impregnation and a dedicated core earth connection. For installations requiring additional protection, the specified enclosure references are EPH 2 or EPN 1. Correct primary and secondary overcurrent protection, protective earthing, ventilation and mounting arrangements remain essential for safe operation.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 150 VA | |
|---|---|---|
| Primary Voltage | 0/240/415V | |
| Secondary Voltage | 0/110V | |
| Phase | Single Phase | |
| Manufacturer | Eastern Transformers & Equipment (ETE) | |
| Series | DV Dual-Input-Voltage Stock Control Transformer Range | |
| Model | DV150P6S4 | |
| Product type | Industrial control circuit transformer | |
| Transformer configuration | Dual-input-voltage primary, single-voltage secondary | |
| Number of phases | Single-phase | |
| Rated apparent power | 150 VA | |
| Primary voltage options | 240 V AC or 415 V AC | |
| Primary terminals | 0/240/415 V | |
| Secondary voltage | 110 V AC | |
| Secondary terminals | 0/110 V | |
| Output connection | 110 V | |
| Rated frequency | 50/60 Hz | |
| Duty rating | Continuous | |
| Insulation class | Class E | |
| Varnish impregnation | Class H | |
| Voltage regulation | 10% | |
| Terminal protection | IP20 touch-proof terminals | |
| Core earthing | Dedicated core earth connection | |
| Ambient operating temperature | −10 °C to +35 °C | |
| Design standard | EN 61558-1 | |
| Mounting | Panel installation with DIN rail mounting option | |
| Calculated full-load secondary current | Approximately 1.36 A | |
| Calculated primary current at 240 V AC | Approximately 0.63 A | |
| Calculated primary current at 415 V AC | Approximately 0.36 A | |
| Length | 96 mm | |
| Width | 87 mm | |
| Height | 103 mm | |
| Dimensions (L × W × H) | 96 × 87 × 103 mm | |
| Weight | 2.8 kg | |
| Enclosure reference | EPH 2 or EPN 1 | |
| Product range reference | ETE Stock Control Transformer Range, March 2026 |
The ETE DV150P6S4 is a 150 VA single-phase dual-input-voltage control transformer designed to provide a nominal 110 V AC output from either a 240 V AC or 415 V AC primary supply. It is suitable for compatible industrial machinery control circuits and auxiliary electrical equipment.
Dual-input voltage means the transformer has 0/240/415 V primary terminals, allowing it to be connected for either a 240 V AC or 415 V AC supply. The correct primary terminal connection must be selected for the available supply voltage.
The ETE DV150P6S4 has a rated apparent power of 150 VA. Connected equipment must remain within this rating and the transformer's applicable operating limits.
The transformer has 0/240/415 V primary terminals and 0/110 V secondary terminals. When connected correctly to either supported primary voltage, it provides a nominal 110 V AC output.
Based on its 150 VA rating and 110 V AC secondary voltage, the calculated full-load secondary current is approximately 1.36 A. Actual transformer selection must also account for connected load characteristics and any inrush requirements.
The DV150P6S4 uses a Class E insulation system designed in accordance with EN 61558-1. Its windings also feature protective Class H varnish impregnation.
The transformer measures 96 mm long, 87 mm wide and 103 mm high, with a specified weight of 2.8 kg.
The ETE DV150P6S4 has a specified 10% voltage regulation. This should be considered when assessing the secondary voltage requirements of connected control equipment under changing load conditions.
Yes. The ETE DV150P6S4 is part of the DV control transformer range offering a DIN rail mounting option for suitable installations. The correct mounting components and arrangement should be confirmed against the manufacturer's instructions.
The specified enclosure references are EPH 2 or EPN 1. Enclosure selection should account for the installation environment, transformer dimensions, ventilation requirements and applicable electrical safety regulations.
No. The ETE DV150P6S4 provides a nominal 110 V AC secondary output, not 110 V DC. Equipment requiring direct current needs a suitable DC power supply or appropriately rated rectification and conditioning equipment.
No. The 0/240/415 V primary terminals provide alternative connections for the supported input voltages. The transformer must be connected using the correct primary terminals for the available supply, following the manufacturer's instructions. It is not designed to combine two independent primary supplies.
ETE DV dual-input-voltage control transformers offer practical flexibility for industrial electrical installations. With its selectable 240 V AC or 415 V AC primary connection, 110 V AC secondary output, 150 VA rating, Class E insulation, 10% voltage regulation and compact industrial construction, the ETE DV150P6S4 provides a dependable solution for OEM machinery, electrical control panels and automation applications requiring a dedicated 110 V AC control supply.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.