2CSM228625R0812 ABB TS164812 TS16/4-8-12 Bell Transformer 16VA 230V AC 4/8/12V AC

2CSM228625R0812 ABB TS164812 TS16/4-8-12 Bell Transformer 16VA 230V AC 4/8/12V AC

ABB TS164812 TS16/4-8-12 is a 16 VA modular bell transformer with a 230 V AC primary and selectable 4 V, 8 V and 12 V AC SELV secondary outputs for bell and low-voltage signalling circuits.

SKU: 2CSM228625R0812Alt SKU: TS164812MPN: 2CSM228625R0812
Price
List Price £107.22 ex VAT
Your Price (ex VAT) Save 35%
£69.69 35% OFF
You save £37.53 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £69.69
Trade pricing is personalised to your account

Manufacturer Lead Time

£69.69

Why Choose the ABB TS164812 TS16/4-8-12 Bell Transformer?

The ABB TS164812 (TS16/4-8-12) is a modular bell transformer designed to provide safety extra-low voltage power for bells and other compatible signalling equipment. Part of the ABB System pro M compact TS transformer range, it provides electrical isolation between the mains supply and low-voltage secondary circuits.

The TS16/4-8-12 operates from a 230 V AC primary supply and provides selectable 4 V AC, 8 V AC and 12 V AC secondary outputs. Its maximum discontinuous-duty rated power is 16 VA, with a rated secondary current of 1.33 A and a maximum output current of 4 A.

Designed as a non-inherently short-circuit-proof bell transformer, the TS164812 incorporates thermal protection that helps maintain the transformer within specified temperature limits during fault conditions. The protective device automatically restores operation once the transformer has cooled sufficiently or the overload has been removed, while its compact 35 × 85 × 65 mm DIN-rail format simplifies installation in modular electrical assemblies.

Key Advantages

  • Purpose-designed bell transformer for extra-low-voltage signalling circuits.
  • 16 VA maximum discontinuous-duty power.
  • 230 V AC primary input for standard mains-powered installations.
  • Selectable 4 V AC, 8 V AC and 12 V AC secondary outputs.
  • Provides a SELV secondary supply for compatible equipment.
  • Integrated thermal protection with automatic restoration after cooling.
  • Compact 35 mm / 2-module DIN-rail format.
  • Designed in accordance with IEC/EN 61558-2-8 requirements for bell and chime transformers.

Key Features

  • ABB System pro M compact TS series.
  • Non-inherently short-circuit-proof bell transformer.
  • 16 VA maximum rated power.
  • 230 V AC primary voltage.
  • 4/8/12 V AC selectable secondary voltage.
  • 1.33 A rated secondary current.
  • 4 A maximum output current.
  • 50/60 Hz rated frequency.
  • SELV secondary output.
  • Integrated thermal protective device.
  • Automatic restoration following sufficient cooling or removal of an overload.
  • Compact modular construction for DIN-rail installations.

Flexible Extra-Low-Voltage Power for Bell and Signalling Circuits

Bell, chime and signalling equipment frequently requires an extra-low-voltage AC supply rather than direct connection to the mains. The ABB TS16/4-8-12 converts a 230 V AC primary supply into selectable 4 V AC, 8 V AC or 12 V AC outputs, allowing one transformer to support several common low-voltage signalling requirements.

The ABB TS range is designed for discontinuous-duty applications and incorporates thermal protection in the secondary circuit. If a short circuit or overload causes excessive heating, the protective device operates and automatically restores the transformer once it has cooled sufficiently or the fault condition has been removed, supporting dependable operation in residential and building installations.

Typical Applications

  • Doorbell circuits.
  • Electric bells and chimes.
  • Low-voltage signalling devices.
  • Residential building signalling systems.
  • Electric lock and door-entry circuits where compatible with the selected output.
  • Electrical distribution boards.
  • DIN-rail assemblies requiring selectable 4 V AC, 8 V AC or 12 V AC SELV power.

Technical Specifications

Tick the specs you need, then view products that match.

Primary Voltage 230V
Rated Power (VA) 16 VA
Phase Single Phase
Secondary Voltage 4/8/12V
Series System pro M compact TS
ABB order code 2CSM228625R0812
Product type Bell transformer
Transformer type Non-inherently short-circuit proof
Maximum rated power 16 VA, discontinuous duty
Primary voltage 230 V AC
Secondary voltages 4 V AC / 8 V AC / 12 V AC
Rated secondary current 1.33 A
Maximum output current 4 A
Rated frequency 50/60 Hz
Secondary circuit SELV
Power loss 4 W
Short-circuit protection Integrated thermal protective device
Mounting DIN rail
Width 35 mm / 2 modules
Height 85 mm
Depth 65 mm
Standard IEC/EN 61558-2-8
Application Bell and extra-low-voltage signalling circuits
Net weight 0.35 kg
Pack quantity 6 pieces
EAN / GTIN 8012542286257

Frequently Asked Questions

What is the ABB TS164812 used for?

The ABB TS164812 is a non-inherently short-circuit-proof bell transformer designed to provide safety extra-low voltage AC power for bells and other compatible signalling equipment.

What is the power rating of the ABB TS16/4-8-12?

The TS16/4-8-12 has a maximum rated power of 16 VA for discontinuous-duty applications.

What secondary voltages does the ABB TS164812 provide?

The transformer provides selectable 4 V AC, 8 V AC and 12 V AC secondary outputs from a 230 V AC primary supply.

What output current is available from the ABB TS16/4-8-12?

The TS16/4-8-12 has a rated secondary current of 1.33 A and a specified maximum output current of 4 A.

Does the ABB TS164812 have short-circuit protection?

Yes. The TS164812 incorporates a thermal protective device that helps protect the transformer during short-circuit or overload conditions and automatically restores operation once sufficient cooling has occurred or the overload has been removed.

Trusted ABB Bell Transformer Power

ABB System pro M compact TS bell transformers provide isolated extra-low-voltage power for signalling circuits, combining selectable secondary voltages, compact DIN-rail installation and integrated thermal protection for dependable building electrical systems.