Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ETE XMS250P4S4 is a 250 VA single-phase Class II enclosed safety/isolating transformer with a 240 V AC primary, 110 V AC secondary, Class F insulation, integral moulded housing and chassis-only mounting.
£47.63
The ETE XMS250P4S4 is a 250 VA single-phase Class II enclosed safety/isolating transformer designed to provide a nominal 110 V AC secondary supply from a 240 V AC primary input. Part of the ETE XMS transformer series, it combines Class II electrical construction, an integral moulded housing and chassis mounting for industrial control panels, electrical machinery and automation equipment.
Featuring 0/240 V primary terminals and 0/110 V secondary terminals, the XMS250P4S4 provides dedicated AC voltage transformation for compatible industrial control circuits. Its Class II construction incorporates protective insulation arrangements, while its safety/isolating transformer design provides electrical separation between the primary and secondary circuits. This makes it a practical choice for installations requiring an enclosed transformer with a defined 240 V to 110 V AC voltage configuration.
The XMS250P4S4 is designed for chassis mounting only, allowing secure installation on a suitable equipment mounting surface. With Class F insulation, dimensions of 126 × 136 × 127 mm and a weight of 4.6 kg, it provides electrical panel builders, OEM machinery manufacturers and maintenance engineers with a practical 250 VA industrial control power solution.
The ETE XMS250P4S4 provides a straightforward method of transforming a nominal 240 V AC primary supply into a 110 V AC secondary supply. Its 250 VA rated capacity makes it suitable for compatible industrial control equipment where the combined apparent power demand remains within the transformer's rating. Typical loads may include AC control relays, contactor coils, signalling devices and other electrical equipment designed for 110 V AC operation.
A key feature of the XMS250P4S4 is its Class II electrical construction. Class II equipment incorporates protective insulation arrangements designed to provide protection against electric shock without relying on a protective earth connection for its protective insulation system. The transformer's safety/isolating designation provides electrical separation between primary and secondary circuits, supporting appropriately engineered industrial control power installations. Class II electrical construction is distinct from the transformer's Class F thermal insulation rating.
The integral moulded housing provides an enclosed transformer format, while the specified chassis-only mounting arrangement allows the unit to be installed on a suitable equipment mounting surface. Unlike smaller XMS models that may offer DIN rail installation, the XMS250P4S4 must be chassis mounted. The mounting surface and fixings should be suitable for its 4.6 kg weight and the conditions of the installation.
At its rated capacity, the calculated nominal secondary current is approximately 2.27 A at 110 V AC. This figure is derived from the 250 VA rating and nominal output voltage rather than a separately verified manufacturer current rating. The calculated ideal primary current is approximately 1.04 A at 240 V AC, excluding transformer losses and magnetising current. Suitable circuit protection, conductor sizing, ventilation and electrical clearances remain essential for dependable operation.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 250 VA | |
|---|---|---|
| Primary Voltage | 0/240V | |
| Secondary Voltage | 0/110V | |
| Phase | Single Phase | |
| Manufacturer | ETE | |
| Series | XMS Class II Enclosed Safety/Isolating Transformers | |
| Model | XMS250P4S4 | |
| Product type | Enclosed safety/isolating transformer | |
| Transformer configuration | Single-phase | |
| Electrical construction | Class II | |
| Rated apparent power | 250 VA | |
| Rated capacity | 0.25 kVA | |
| Primary terminals | 0/240 V | |
| Nominal primary voltage | 240 V AC | |
| Secondary terminals | 0/110 V | |
| Nominal secondary voltage | 110 V AC | |
| Output connection | 110 V AC | |
| Calculated nominal secondary current | Approximately 2.27 A at 110 V, based on 250 VA | |
| Calculated ideal primary current | Approximately 1.04 A at 240 V, based on 250 VA and excluding transformer losses | |
| Insulation class | F | |
| Housing | Integral moulded housing | |
| Mounting method | Chassis mounting only | |
| DIN rail mounting | Not specified for this model | |
| Length | 126 mm | |
| Width | 136 mm | |
| Height | 127 mm | |
| Dimensions (L × W × H) | 126 × 136 × 127 mm | |
| Weight | 4.6 kg | |
| Enclosure reference | Integral moulded housing | |
| Product range | ETE Stock Control Transformers | |
| Catalogue reference | ETE Stock Control Transformer Range, March 2026 |
The ETE XMS250P4S4 is a 250 VA single-phase Class II enclosed safety/isolating transformer used to provide a nominal 110 V AC supply from a 240 V AC primary input for compatible industrial control circuits, electrical panels and automation equipment.
The transformer has a rated apparent power of 250 VA (0.25 kVA). The combined apparent power demand of connected equipment should remain within the transformer's specified rating.
The transformer features 0/240 V primary terminals and is designed for a nominal 240 V AC primary supply.
The transformer features 0/110 V secondary terminals and provides a nominal 110 V AC output when connected to its specified primary supply.
Class II construction means the transformer incorporates protective insulation arrangements designed to provide protection against electric shock without relying on a protective earth connection for its protective insulation system. Correct installation and suitable circuit protection remain essential.
Yes. The XMS250P4S4 is specified as a Class II enclosed safety/isolating transformer. It provides electrical separation between primary and secondary circuits for compatible applications, subject to correct installation and the requirements of the complete electrical system.
No. The ETE XMS250P4S4 is specified for chassis mounting only. DIN rail mounting is not a stated mounting option for this model.
The transformer must be chassis mounted on an appropriate equipment mounting surface. The mounting arrangement and fixings should support its 4.6 kg weight and meet the manufacturer's installation requirements.
Based on its 250 VA rating and nominal 110 V AC output, the calculated secondary current is approximately 2.27 A. This is a calculated value rather than a separately verified manufacturer current rating, and actual loading must comply with the manufacturer's requirements.
The transformer uses Class F insulation, providing a defined thermal insulation classification. This is separate from its Class II electrical construction.
The transformer measures 126 × 136 × 127 mm (L × W × H) and weighs 4.6 kg. These dimensions and its weight should be considered when planning the chassis mounting arrangement.
Yes. The XMS250P4S4 is supplied with an integral moulded housing. Depending on the installation environment, the overall electrical assembly may still require an additional protective cabinet or enclosure.
Installation should account for the specified 240 V AC primary supply, 110 V AC secondary output, 250 VA capacity, suitable circuit protection, conductor sizing, ventilation and the chassis-only mounting requirement. The mounting arrangement must support the transformer's 4.6 kg weight, and all connections should follow the manufacturer's instructions.
ETE XMS Class II enclosed safety/isolating transformers offer a practical solution for industrial control applications requiring enclosed AC voltage transformation and defined mounting arrangements. With a 240 V primary, 110 V secondary, 250 VA capacity, Class II construction, Class F insulation and chassis mounting, the XMS250P4S4 provides electrical panel builders, OEM machinery manufacturers and automation engineers with a dependable option for industrial control power.
We use cookies