Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ETE XMS100P5S6 is a 100 VA single-phase Class II enclosed safety/isolating transformer with a 415 V AC primary input, 24 V AC secondary output, Class F insulation, integral moulded housing and DIN rail or chassis mounting.
£28.50
The ETE XMS100P5S6 is a compact 100 VA single-phase Class II enclosed safety/isolating transformer designed to provide a nominal 24 V AC output from a 415 V AC primary supply. Part of the ETE XMS Class II transformer series, it is suitable for industrial control panels, electrical machinery and automation equipment requiring a dedicated isolated low-voltage AC supply.
The transformer features 0/415 V primary terminals and 0/24 V secondary terminals, providing a straightforward voltage conversion arrangement. Its Class II construction provides protection against electric shock through a protective insulation system that does not rely on a protective earth connection. The integral moulded housing provides an enclosed construction suitable for integration into electrical equipment.
With Class F insulation, a rated capacity of 100 VA and flexible DIN rail or chassis mounting, the ETE XMS100P5S6 offers a practical solution for electrical engineers and panel builders. Its compact dimensions of 90 × 106 × 96 mm and weight of 2.2 kg make it suitable for space-conscious industrial control cabinet installations.
The ETE XMS100P5S6 uses electromagnetic induction to transfer electrical energy from its 415 V AC primary winding to a nominal 24 V AC secondary winding. This provides electrical isolation between the primary supply and the connected low-voltage control circuit, supporting safe and effective power distribution when installed in accordance with the manufacturer's instructions.
Its 100 VA rating corresponds to a calculated nominal secondary current of approximately 4.17 A at 24 V AC. This makes the transformer suitable for appropriately rated relays, contactors, signalling equipment and auxiliary control devices. The total connected load must remain within the transformer's rated capacity.
The Class II protective insulation arrangement is an important feature of the XMS series. Unlike equipment whose electrical protection relies on a protective earth connection, Class II construction uses additional protective insulation measures. This does not remove the need for suitable circuit protection, correct installation or compliance with applicable electrical regulations.
The integral moulded housing and DIN rail or chassis mounting options make the XMS100P5S6 particularly convenient for panel builders and machinery manufacturers requiring an enclosed transformer within an industrial electrical cabinet.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 100 VA | |
|---|---|---|
| Primary Voltage | 0/415V | |
| Secondary Voltage | 0/24V | |
| Phase | Single Phase | |
| Manufacturer | ETE | |
| Series | XMS Class II Enclosed Safety/Isolating Transformers | |
| Model | XMS100P5S6 | |
| Product type | Enclosed safety/isolating transformer | |
| Number of phases | Single-phase | |
| Rated apparent power | 100 VA | |
| Primary terminals | 0/415 V | |
| Nominal primary voltage | 415 V AC | |
| Secondary terminals | 0/24 V | |
| Output connection | 24 V | |
| Nominal secondary voltage | 24 V AC | |
| Calculated nominal full-load secondary current | Approximately 4.17 A | |
| Electrical protection class | Class II | |
| Insulation class | Class F | |
| Enclosure reference | Integral moulded housing | |
| Mounting type | DIN rail or chassis mounting | |
| Length | 90 mm | |
| Width | 106 mm | |
| Height | 96 mm | |
| Dimensions (L × W × H) | 90 × 106 × 96 mm | |
| Weight | 2.2 kg | |
| Product range | ETE Stock Control Transformer Range | |
| Reference | ETE Price List March 2026 |
The ETE XMS100P5S6 is a 100 VA Class II safety/isolating transformer designed to provide a nominal 24 V AC supply from a 415 V AC input for compatible industrial control equipment.
The transformer has 0/415 V primary terminals and 0/24 V secondary terminals, providing a nominal 24 V AC output from a 415 V AC supply.
Class II means the transformer incorporates a protective insulation arrangement that does not rely on a protective earth connection for protection against electric shock.
The transformer is rated at 100 VA, corresponding to approximately 4.17 A at 24 V AC under nominal full-load conditions.
Yes. The transformer supports DIN rail or chassis mounting for flexible installation within suitable electrical control panels.
The ETE XMS100P5S6 incorporates Class F insulation, a thermal insulation classification associated with a temperature limit of 155 °C.
The transformer measures 90 × 106 × 96 mm and weighs 2.2 kg.
Yes. It features an integral moulded housing as part of its Class II enclosed safety/isolating transformer construction.
ETE XMS Class II enclosed safety/isolating transformers offer dependable isolated control power for industrial electrical installations. The XMS100P5S6 combines a 100 VA rating, 415 V AC primary input, 24 V AC output, Class F insulation and flexible DIN rail or chassis mounting for practical industrial control applications.
The ETE XMS150P4S6 is a reliable 150 VA single-phase Class II enclosed safety/isolating transformer designed to convert a nominal 240 V AC primary supply into a 24 V AC secondary output. As part of the ETE XMS Class II transformer series, it provides isolated low-voltage AC power for industrial electrical control panels, machinery and automation systems.
The transformer features 0/240 V primary terminals and 0/24 V secondary terminals, providing a straightforward connection arrangement for compatible industrial electrical supplies. Its Class II protective insulation provides protection against electric shock without relying on a protective earth connection, while the integral moulded housing offers an enclosed construction.
With a rated apparent power of 150 VA, Class F insulation and flexible DIN rail or chassis mounting, the ETE XMS150P4S6 is suitable for supplying compatible 24 V AC relays, contactors and auxiliary control devices. Its dimensions of 102 × 115.5 × 106 mm and weight of 3 kg support installation within suitably designed industrial electrical cabinets.
The ETE XMS150P4S6 uses electromagnetic induction to transfer electrical energy between its primary and secondary windings. When connected to its specified 240 V AC primary supply, it provides a nominal 24 V AC secondary output for compatible low-voltage electrical equipment.
The transformer has a rated apparent power of 150 VA, corresponding to a calculated nominal full-load secondary current of 6.25 A at 24 V AC. This makes it suitable for industrial control relays, contactor coils, signalling devices and other compatible equipment, provided the total connected load remains within the transformer's rated capacity.
The Class II construction incorporates protective insulation measures that do not depend on a protective earth connection. This provides an important electrical safety characteristic for installations requiring Class II equipment, while appropriate circuit protection and installation practices remain essential.
The Class F insulation system, integral moulded housing and flexible mounting options make the XMS150P4S6 a practical choice for industrial panel builders. Its DIN rail or chassis mounting capability allows straightforward integration into suitable electrical cabinets and machinery enclosures.
The ETE XMS150P4S6 is a 150 VA Class II enclosed safety/isolating transformer used to provide 24 V AC power from a 240 V AC input for compatible industrial control equipment.
The transformer has 0/240 V primary terminals and 0/24 V secondary terminals, providing a nominal 24 V AC output from a 240 V AC supply.
The transformer is rated at 150 VA, corresponding to a calculated nominal full-load secondary current of 6.25 A at 24 V AC.
Class II construction means the transformer uses a protective insulation arrangement that does not rely on a protective earth connection for protection against electric shock.
Yes. The transformer supports DIN rail or chassis mounting for installation within suitable electrical cabinets and control panels.
The ETE XMS150P4S6 uses Class F insulation, a thermal insulation classification associated with a temperature limit of 155 °C.
The transformer measures 102 × 115.5 × 106 mm and weighs 3 kg.
Yes. It features an integral moulded housing as part of its enclosed Class II safety/isolating transformer construction.
ETE XMS Class II enclosed safety/isolating transformers provide dependable isolated low-voltage power for industrial control systems. The XMS150P4S6 combines a 150 VA rating, 240 V AC primary input, 24 V AC secondary output, Class F insulation and flexible mounting for practical electrical panel installations.
The ETE MV300P2S3 is a versatile 300 VA single-phase multi-voltage control transformer designed to provide flexible low-voltage AC power for industrial control circuits, machinery and automation systems. Part of the ETE MV multi-voltage transformer series, it features a multi-terminal primary winding and two separate secondary windings that can be configured to provide a nominal 12 V AC or 24 V AC output.
The transformer features 20/0/380/420 V primary terminals and 0/12 V + 0/12 V secondary terminals. The secondary windings can be connected in parallel for a nominal 12 V AC output or in series for a nominal 24 V AC output, following the correct winding polarity and manufacturer's connection instructions.
With a rated apparent power of 300 VA, Class E insulation and specified 8% voltage regulation, the ETE MV300P2S3 is suitable for a range of industrial control power applications. Its dimensions of 120 × 100 × 120 mm, weight of 4.7 kg and specified EPH 3 or EPN 2 enclosure references support integration into industrial electrical cabinets. The transformer also incorporates a 20 V primary adjustment tap, and its correct connections must be confirmed with ETE.
The ETE MV300P2S3 uses electromagnetic induction to transfer electrical power between its primary and secondary windings. Its multi-terminal primary arrangement provides the specified voltage connection options, while the two separate 12 V secondary windings enable configurable low-voltage AC outputs.
When correctly connected in parallel, the secondary windings provide a nominal 12 V AC output. When correctly connected in series, they provide a nominal 24 V AC output. Correct winding polarity is essential, particularly for parallel operation, to prevent circulating currents or incorrect output voltages.
The transformer's 300 VA rating corresponds to a calculated nominal full-load output current of 25 A at 12 V AC or 12.5 A at 24 V AC, assuming the full rated capacity is available in the selected configuration. The actual permissible winding currents must comply with the manufacturer's connection and loading instructions.
The primary includes a 20 V adjustment tap as part of the 20/0/380/420 V terminal arrangement. The correct primary connections must be confirmed with ETE before energising the transformer. This is particularly important when selecting a primary configuration for an industrial electrical supply.
The Class E insulation system, specified 8% voltage regulation and compact industrial construction make the MV300P2S3 suitable for control panels and machinery requiring configurable low-voltage AC power.
The ETE MV300P2S3 is a 300 VA single-phase multi-voltage control transformer used to supply compatible industrial control equipment with 12 V AC or 24 V AC.
The transformer features 20/0/380/420 V primary terminals, including a 20 V adjustment tap. Correct connections must be confirmed with ETE.
Yes. Its two 12 V secondary windings can be connected in parallel for 12 V AC or in series for 24 V AC, following the correct manufacturer-approved connections.
The ETE MV300P2S3 has a rated apparent power of 300 VA.
At the full 300 VA rating, the calculated nominal secondary current is 25 A at 12 V AC or 12.5 A at 24 V AC, subject to the manufacturer's winding ratings and connection instructions.
The 20 V adjustment tap forms part of the transformer's multi-voltage primary arrangement. The correct use and connections must be confirmed with ETE before installation.
The transformer incorporates Class E insulation and has a specified 8% voltage regulation.
The transformer measures 120 × 100 × 120 mm and weighs 4.7 kg.
The specified enclosure references are EPH 3 or EPN 2, providing enclosure options for suitable industrial electrical installations.
ETE MV multi-voltage control transformers provide flexible AC voltage conversion for industrial machinery and electrical automation systems. The MV300P2S3 combines a 300 VA rating, configurable 12 V or 24 V secondary outputs, Class E insulation and 8% voltage regulation for practical industrial control power applications.
The ETE XMS150P5S6 is a dependable 150 VA single-phase Class II enclosed safety/isolating transformer designed to provide a nominal 24 V AC output from a 415 V AC primary supply. Part of the ETE XMS Class II transformer series, it offers isolated low-voltage AC power for industrial control panels, electrical machinery and automation equipment.
The transformer features 0/415 V primary terminals and 0/24 V secondary terminals, providing a dedicated voltage conversion arrangement for compatible industrial electrical installations. Its Class II protective insulation provides electrical protection without reliance on a protective earth connection, while the integral moulded housing provides an enclosed transformer construction.
With a rated apparent power of 150 VA, Class F insulation and flexible DIN rail or chassis mounting, the ETE XMS150P5S6 is suitable for supplying compatible 24 V AC control relays, contactors and auxiliary electrical equipment. Its dimensions of 102 × 115.5 × 106 mm and weight of 3 kg support installation within suitably designed industrial electrical cabinets.
The ETE XMS150P5S6 uses electromagnetic induction to convert a nominal 415 V AC primary supply into a nominal 24 V AC secondary output. Its primary and secondary windings provide galvanic isolation, supporting the supply of compatible low-voltage control circuits within industrial electrical equipment.
The transformer has a rated apparent power of 150 VA, corresponding to a calculated nominal full-load secondary current of 6.25 A at 24 V AC. This makes it suitable for appropriately rated control relays, contactor coils, signalling devices and auxiliary electrical equipment. The connected load must remain within the transformer's rated capacity.
The Class II construction uses a protective insulation arrangement that does not depend on a protective earth connection. This makes the transformer suitable for electrical installations requiring Class II equipment, subject to appropriate circuit protection and compliance with the manufacturer's installation instructions.
The Class F insulation system, integral moulded housing and flexible mounting options support practical installation within industrial electrical cabinets. Its DIN rail or chassis mounting capability provides flexibility for panel builders and machinery manufacturers.
The ETE XMS150P5S6 is a 150 VA Class II enclosed safety/isolating transformer designed to provide nominal 24 V AC power from a 415 V AC supply for compatible industrial control equipment.
The transformer has 0/415 V primary terminals and 0/24 V secondary terminals, providing a nominal 24 V AC output from a 415 V AC input.
The transformer is rated at 150 VA, corresponding to a calculated nominal full-load secondary current of 6.25 A at 24 V AC.
Class II construction means the transformer incorporates a protective insulation arrangement that does not rely on a protective earth connection for protection against electric shock.
Yes. The transformer supports DIN rail or chassis mounting, providing flexibility for suitable industrial electrical cabinet installations.
The ETE XMS150P5S6 uses Class F insulation, a thermal insulation classification associated with a temperature limit of 155 °C.
The transformer measures 102 × 115.5 × 106 mm and weighs 3 kg.
Yes. The ETE XMS150P5S6 features an integral moulded housing as part of its Class II enclosed safety/isolating construction.
ETE XMS Class II enclosed safety/isolating transformers provide dependable isolated AC power for industrial control equipment. The XMS150P5S6 combines a 150 VA rating, 415 V AC primary input, 24 V AC output, Class F insulation and DIN rail or chassis mounting for reliable industrial electrical installations.
The ETE DV750P6S4 is a robust 750 VA single-phase dual-input-voltage control transformer designed to provide a nominal 110 V AC secondary supply for industrial electrical control circuits, machinery and automation systems. Part of the ETE DV dual-input-voltage transformer series, it offers flexible primary supply connections for installations operating from nominal 240 V or 415 V AC.
The transformer features 0/240/415 V primary terminals and 0/110 V secondary terminals, allowing the appropriate primary voltage connection to be selected while providing a nominal 110 V AC output. This arrangement makes the DV750P6S4 suitable for industrial machinery, switchgear and electrical control equipment requiring a dedicated transformer supply.
With a rated apparent power of 750 VA, Class E insulation and specified 4% voltage regulation, the ETE DV750P6S4 provides dependable power conversion for substantial industrial control loads. Its dimensions of 150 × 108 × 145 mm, weight of 7.6 kg and specified EPN 3 enclosure reference support installation within suitably designed industrial electrical cabinets.
The ETE DV750P6S4 dual-input-voltage transformer uses electromagnetic induction to transfer electrical energy from its primary winding to an electrically isolated secondary winding. Its 0/240/415 V primary terminals allow connection to the appropriate nominal 240 V or 415 V AC supply, while the secondary provides a nominal 110 V AC output.
The transformer's 750 VA rated apparent power corresponds to a calculated nominal full-load secondary current of approximately 6.82 A at 110 V AC. This makes it suitable for compatible control relays, contactor coils, signalling equipment and auxiliary electrical systems, provided the total connected load remains within the transformer's rated capacity.
Its specified 4% voltage regulation describes the change in secondary voltage between no-load and rated-load conditions. This characteristic is useful for industrial control equipment where a reasonably consistent AC supply is important as the connected electrical load varies.
The Class E insulation system and robust transformer construction support integration into industrial electrical cabinets and machinery control assemblies. The specified EPN 3 enclosure reference identifies the suitable enclosure option, while the transformer's 7.6 kg weight should be considered when designing the mounting arrangement.
The ETE DV750P6S4 is a 750 VA single-phase dual-input-voltage control transformer designed to provide nominal 110 V AC power for compatible industrial control circuits and electrical equipment.
The transformer has 0/240/415 V primary terminals, allowing connection to the appropriate nominal 240 V or 415 V AC supply.
The transformer features 0/110 V secondary terminals and provides a nominal 110 V AC output when correctly connected.
The transformer has a rated apparent power of 750 VA, making it suitable for substantial industrial control power applications.
At the nominal 110 V AC secondary output, the 750 VA rating corresponds to a calculated full-load current of approximately 6.82 A.
The ETE DV750P6S4 incorporates Class E insulation, a thermal insulation classification associated with a temperature limit of 120 °C.
The specified 4% voltage regulation describes the change in secondary voltage between no-load and rated-load operation, helping engineers assess voltage stability under varying control circuit loads.
The transformer measures 150 × 108 × 145 mm and weighs 7.6 kg.
The specified enclosure reference is EPN 3, which should be selected according to the requirements of the intended electrical installation.
ETE DV dual-input-voltage control transformers provide dependable voltage conversion for industrial electrical systems. The DV750P6S4 combines a 750 VA rating, selectable 240 V or 415 V AC primary connections, a 110 V AC secondary output, Class E insulation and 4% voltage regulation for reliable industrial control power applications.
We use cookies