ETE XMS100P5S4 Class II Enclosed Safety Transformer 100VA 0/415V to 0/110V

ETE XMS100P5S4 Class II Enclosed Safety Transformer 100VA 0/415V to 0/110V

ETE XMS100P5S4 is a 100 VA single-phase Class II enclosed safety/isolating transformer with a 415 V AC primary, 110 V AC secondary, Class F insulation, integral moulded housing and DIN rail or chassis mounting options.

SKU: XMS100P5S4MPN: XMS100P5S4
Price
List Price £38.00 ex VAT
Your Price (ex VAT) Save 25%
£28.50 25% OFF
You save £9.50 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £28.50
Trade pricing is personalised to your account

Manufacturer Lead Time

£28.50

Why Choose the ETE XMS100P5S4 100 VA Class II Enclosed Safety/Isolating Transformer?

The ETE XMS100P5S4 is a compact 100 VA single-phase Class II enclosed safety/isolating transformer designed for industrial electrical control panels, machinery, automation equipment and AC control circuits. Part of the ETE XMS enclosed transformer range, it converts a nominal 415 V AC primary supply into a 110 V AC secondary output, providing a practical solution for industrial equipment requiring a lower control voltage.

The XMS100P5S4 features a 0/415 V primary terminal arrangement and a 0/110 V secondary terminal arrangement. Its Class II protective construction and integral moulded housing provide an enclosed transformer design suitable for integration into compatible electrical assemblies. The transformer supports DIN rail or chassis mounting, offering installation flexibility for different control panel layouts and equipment configurations.

With a rated apparent power of 100 VA and Class F insulation, the ETE XMS100P5S4 is suitable for appropriately rated 110 V AC control loads. Its dimensions of 90 × 106 × 96 mm and weight of 2.2 kg make it a convenient choice for electrical cabinets where efficient use of installation space is important. The specified enclosure is an integral moulded housing.

Key Advantages

  • 100 VA rated capacity for industrial control and signalling applications requiring a moderate AC control power supply.
  • 415 V AC primary input for compatible industrial electrical supplies.
  • 110 V AC secondary output for industrial control equipment requiring this operating voltage.
  • Class II construction provides a double-insulated or reinforced-insulation protective design.
  • Safety/isolating transformer configuration provides electrical separation between primary and secondary circuits.
  • Integral moulded housing provides an enclosed transformer assembly.
  • DIN rail mounting capability supports convenient installation in compatible electrical control cabinets.
  • Chassis mounting option provides additional installation flexibility.
  • Class F insulation provides a specified thermal insulation classification.
  • Compact 90 × 106 × 96 mm dimensions help conserve valuable electrical panel space.

Key Features

  • ETE XMS Class II enclosed safety/isolating transformer series.
  • 100 VA rated apparent power.
  • Single-phase transformer configuration.
  • Primary terminals: 0/415 V.
  • Nominal primary voltage: 415 V AC.
  • Secondary terminals: 0/110 V.
  • Nominal secondary output: 110 V AC.
  • Output connection: 110 V.
  • Protection construction: Class II.
  • Transformer type: Enclosed safety/isolating transformer.
  • Mounting options: DIN rail or chassis mounting.
  • Insulation class: F.
  • Enclosure: Integral moulded housing.
  • Dimensions: 90 × 106 × 96 mm.
  • Weight: 2.2 kg.

415 V AC Input with 110 V AC Safety/Isolating Output

The ETE XMS100P5S4 is designed to convert a nominal 415 V AC input into a 110 V AC output for compatible industrial control and signalling equipment. Its primary winding uses 0/415 V terminals, while its secondary winding uses 0/110 V terminals, providing a straightforward fixed-voltage transformer configuration.

Unlike multi-tap transformers with selectable secondary voltages, the XMS100P5S4 is specified with a single 110 V AC output connection. This makes it suitable for installations where the required control voltage is known and a compact, enclosed transformer is preferred. Its 100 VA capacity supports appropriately rated control loads without requiring a larger transformer than the application demands.

Based on its 100 VA rating, the theoretical full-load secondary current is approximately 0.91 A at 110 V AC. This is calculated by dividing the rated apparent power by the nominal secondary voltage. Actual permissible loading, protective device selection and operating conditions must follow ETE's specifications and the requirements of the connected equipment.

The transformer's Class II construction provides a protective insulation arrangement, while its Class F insulation defines the winding insulation thermal classification. These are separate characteristics and should not be confused. The integral moulded housing and DIN rail or chassis mounting options support installation into suitable electrical assemblies. Correct primary and secondary connections, circuit protection, ventilation and mounting arrangements remain essential for safe operation, particularly when working with a 415 V AC primary supply.

Typical Applications

  • Industrial electrical control panels requiring 110 V AC.
  • Machinery control circuits supplied from 415 V AC.
  • 110 V AC relay and contactor control circuits.
  • Industrial signalling and indication equipment.
  • Motor control centres with compatible 415 V AC control transformer supplies.
  • OEM electrical equipment requiring an enclosed safety/isolating transformer.
  • Automation cabinets with DIN rail-mounted components.
  • Chassis-mounted electrical control assemblies.
  • Compatible industrial monitoring and control accessories.
  • Replacement of existing 415 V to 110 V AC transformers with matching electrical and mechanical specifications.

Technical Specifications

Tick the specs you need, then view products that match.

Rated Power (VA) 100 VA
Primary Voltage 0/415V
Secondary Voltage 0/110V
Phase Single Phase
Manufacturer ETE
Series XMS Class II Enclosed Safety/Isolating Transformers
Model XMS100P5S4
Product type Enclosed safety/isolating transformer
Rated apparent power 100 VA
Number of phases Single-phase
Primary terminal arrangement 0/415 V
Primary voltage 415 V AC
Secondary terminal arrangement 0/110 V
Secondary voltage 110 V AC
Output connection 110 V
Protection class Class II
Insulation class F
Mounting DIN rail or chassis
Enclosure reference Integral moulded housing
Length 90 mm
Width 106 mm
Height 96 mm
Dimensions (L × W × H) 90 × 106 × 96 mm
Weight 2.2 kg
Product range reference ETE Stock Control Transformer Range, March 2026

Frequently Asked Questions

What is the ETE XMS100P5S4 used for?

The ETE XMS100P5S4 is a 100 VA single-phase Class II enclosed safety/isolating transformer designed to convert a 415 V AC supply into a 110 V AC output for compatible industrial control, signalling and automation applications.

What primary voltage does the XMS100P5S4 require?

The transformer has a 0/415 V primary terminal arrangement and is specified for a nominal 415 V AC input.

What secondary voltage does the ETE XMS100P5S4 provide?

The transformer provides a nominal 110 V AC secondary output through its 0/110 V secondary terminals.

What is the power rating of the XMS100P5S4?

The transformer has a rated apparent power of 100 VA, making it suitable for appropriately rated 110 V AC control and signalling equipment.

What does Class II mean on the XMS100P5S4?

Class II identifies a protective insulation construction based on double or reinforced insulation rather than reliance on a protective earth connection for basic electrical shock protection. The transformer must still be installed and connected according to ETE's instructions.

What output current can the XMS100P5S4 provide?

Based on the 100 VA rating and 110 V AC output, the theoretical full-load secondary current is approximately 0.91 A. Actual permissible loading must follow ETE's specifications.

Can the ETE XMS100P5S4 be mounted on a DIN rail?

Yes. The XMS100P5S4 is specified for DIN rail or chassis mounting, allowing it to be installed in compatible electrical control cabinets and equipment assemblies.

What are the dimensions and weight of the XMS100P5S4?

The transformer measures 90 mm long × 106 mm wide × 96 mm high and weighs 2.2 kg.

What insulation class and enclosure does the XMS100P5S4 have?

The transformer features Class F insulation and an integral moulded housing. Its protective construction is Class II, which is distinct from the Class F thermal insulation rating.

A Practical Choice for Industrial Control Panel Builders

The ETE XMS100P5S4 combines a 100 VA rating, 415 V AC primary input, 110 V AC secondary output, Class II protective construction, Class F insulation and an integral moulded enclosure. With DIN rail or chassis mounting options, it offers a compact and flexible solution for industrial control panel builders, OEM equipment manufacturers and electrical maintenance engineers requiring an enclosed AC safety/isolating transformer.