ETE WV750P7S8 is a 750 VA single-phase wide-input-voltage control transformer with 0/380/400/420/440/460/480 V primary terminals, dual 0/110/120 V secondary windings configurable for 110/120 V parallel or 220/240 V series output, Class E insulation and 4% voltage regulation.
£105.30
The ETE WV750P7S8 is a versatile 750 VA single-phase wide-input-voltage control transformer designed to provide dependable AC voltage transformation and electrical isolation for industrial machinery, electrical control panels and automation systems. Part of the ETE WV stock control transformer range, it combines multiple primary voltage connections with configurable secondary windings, making it a practical choice for control panel builders, OEM machine manufacturers and industrial maintenance engineers.
The WV750P7S8 features primary terminals marked 0/380/400/420/440/460/480 V, providing six nominal input voltage options for industrial electrical installations. Its dual 0/110/120 V secondary windings can be connected in parallel for 110 V or 120 V AC output, or in series for 220 V or 240 V AC output. This flexible arrangement allows one transformer model to accommodate several common industrial control voltage requirements.
With a rated capacity of 750 VA, Class E insulation and 4% voltage regulation, the ETE WV750P7S8 provides substantial control power capacity with relatively low specified voltage regulation. Measuring 150 × 108 × 145 mm and weighing 7.6 kg, it is suitable for integration into appropriately designed industrial electrical equipment, with an associated EPN 3 enclosure reference.
The ETE WV750P7S8 transforms a selected industrial AC input voltage into a secondary supply suitable for compatible control equipment. Its six nominal primary voltage connections support installations using 380 V, 400 V, 420 V, 440 V, 460 V or 480 V AC supplies. This flexibility can simplify transformer selection across machinery and electrical installations with different nominal supply voltages, provided the correct primary terminal is selected.
On the secondary side, the transformer incorporates two separate windings, each marked 0/110/120 V. When correctly connected in parallel, corresponding winding taps provide a 110 V or 120 V AC supply. When connected in an additive series arrangement, they provide 220 V or 240 V AC. Parallel connections require matching voltage taps and winding polarity, while series connections must use the correct additive polarity arrangement. All connections must follow ETE's terminal identification and wiring instructions.
The transformer's 750 VA capacity is the total rated apparent power, not a separate 750 VA allowance for each secondary winding. This capacity can support one or more compatible control loads, provided their combined operating and starting demands remain within the permitted transformer and winding ratings. Its specified 4% voltage regulation should be considered when selecting connected equipment, particularly where voltage tolerance is important.
With Class E insulation, dimensions of 150 × 108 × 145 mm and a 7.6 kg weight, the WV750P7S8 is suited to appropriately supported industrial control panel installations. The associated EPN 3 enclosure reference identifies the manufacturer's enclosure option. Installation design should account for adequate mechanical support, ventilation, electrical protection, earthing and safe access to terminals.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 750 VA | |
|---|---|---|
| Primary Voltage | 0/380/400/420/440/460/480V | |
| Secondary Voltage | 0/110/120V + 0/110/120V | |
| Phase | Single Phase | |
| Manufacturer | ETE | |
| Product range | WV Wide-Input-Voltage Stock Control Transformers | |
| Model / SKU | WV750P7S8 | |
| Product type | Wide-input-voltage industrial control transformer | |
| Phase configuration | Single-phase | |
| Rated apparent power | 750 VA | |
| Primary terminals | 0/380/400/420/440/460/480 V | |
| Nominal primary voltage options | 380/400/420/440/460/480 V AC | |
| Number of nominal primary voltage options | 6 | |
| Secondary terminals | 0/110/120 V + 0/110/120 V | |
| Secondary winding configuration | Dual tapped 110/120 V AC windings | |
| Parallel output connection | 110 V or 120 V AC | |
| Series output connection | 220 V or 240 V AC | |
| Total transformer capacity | 750 VA | |
| Insulation class | E | |
| Voltage regulation | 4% | |
| Length | 150 mm | |
| Width | 108 mm | |
| Height | 145 mm | |
| Dimensions (L × W × H) | 150 × 108 × 145 mm | |
| Weight | 7.6 kg | |
| Enclosure reference | EPN 3 | |
| Catalogue reference | ETE Stock Control Transformer Range, March 2026 |
The ETE WV750P7S8 is a 750 VA single-phase wide-input-voltage control transformer designed to provide isolated AC supplies for industrial machinery, control panels and compatible automation equipment. Its secondary windings support 110 V, 120 V, 220 V or 240 V AC output configurations.
The transformer has a total rated apparent power of 750 VA. This is the overall transformer capacity and must not be interpreted as 750 VA available independently from each secondary winding.
Its primary terminals are marked 0/380/400/420/440/460/480 V, providing nominal input voltage options of 380 V, 400 V, 420 V, 440 V, 460 V and 480 V AC.
The transformer has dual 0/110/120 V secondary windings. They can be connected in parallel for 110 V or 120 V AC, or in series for 220 V or 240 V AC, using the appropriate winding connections.
For 110 V or 120 V AC, the corresponding secondary taps are connected in parallel with matching polarity. For 220 V or 240 V AC, the corresponding windings are connected in series with additive polarity. Connections must follow ETE's terminal identification and wiring instructions.
The transformer has Class E insulation, providing a defined thermal insulation classification for operation within the manufacturer's specified limits.
The ETE WV750P7S8 has 4% voltage regulation. This describes the specified variation in secondary voltage between no-load and rated-load conditions and should be considered when selecting connected control equipment.
The transformer measures 150 × 108 × 145 mm (length × width × height) and weighs 7.6 kg.
The specified enclosure reference is EPN 3. The installation should provide suitable mounting support, ventilation, electrical protection and access for wiring and maintenance.
Yes. Its 750 VA total rated capacity can support multiple compatible devices, provided their combined apparent power, starting demands and operating requirements remain within the transformer's overall and individual winding limits.
Yes. The transformer includes a nominal 400 V AC primary connection, alongside 380 V, 420 V, 440 V, 460 V and 480 V AC options. The correct primary terminal must be selected and wired according to the manufacturer's instructions.
The ETE WV750P7S8 combines 750 VA capacity, six nominal primary voltage options and configurable dual 110/120 V secondary windings in a robust industrial control transformer. With 110/120 V parallel or 220/240 V series output, Class E insulation and 4% voltage regulation, it provides a flexible solution for compatible industrial control and auxiliary AC power applications.