ETE WV50P7S7 is a 50 VA single-phase wide-input-voltage industrial control transformer with 0/380/400/420/440/460/480 V primary terminals, dual 24 V secondary windings configurable for 24 V parallel or 48 V series output, Class E insulation and 15% voltage regulation.
£25.73
The ETE WV50P7S7 is a compact and versatile 50 VA single-phase wide-input-voltage control transformer designed to provide reliable voltage transformation and electrical isolation for industrial control circuits, machinery and automation systems. As part of the ETE WV wide-input-voltage stock control transformer range, it is particularly suitable for electrical control panel builders, OEM machine manufacturers and maintenance engineers requiring flexible primary voltage selection and dual secondary winding configurations.
The WV50P7S7 features seven primary terminals marked 0/380/400/420/440/460/480 V, providing multiple nominal input voltage connections for industrial electrical supplies. Its dual 0/24 V secondary windings can be connected in parallel to provide a 24 V AC output or in series to provide a 48 V AC output. This flexible arrangement allows the transformer to support different control voltage requirements while reducing the need for separate transformer models.
With a rated apparent power of 50 VA, Class E insulation and 15% voltage regulation, the WV50P7S7 is suitable for smaller industrial control loads, including compatible relays, contactor coils, signalling equipment and auxiliary circuits. Its compact dimensions of 75 × 65 × 88 mm and weight of just 1 kg make it a practical choice for space-conscious electrical installations, with associated EPH 1 or EPN 1 enclosure references.
Industrial control transformers such as the ETE WV50P7S7 convert incoming AC supplies into lower secondary voltages suitable for control equipment, machinery and auxiliary electrical circuits. The transformer provides electrical isolation between the primary and secondary windings, allowing compatible low-voltage control equipment to operate from a dedicated transformer supply.
The WV50P7S7 features a particularly flexible primary terminal arrangement with nominal connections for 380 V, 400 V, 420 V, 440 V, 460 V and 480 V AC. This wide range makes the transformer suitable for industrial installations operating at different supply voltages, provided the appropriate primary terminal is selected and the installation complies with the manufacturer's connection instructions.
On the secondary side, the transformer incorporates two separate 24 V AC windings. These can be connected in parallel for a 24 V AC output or in series for a 48 V AC output. Parallel connections must maintain the correct winding polarity, while series connections must use the correct additive winding arrangement. The transformer's total rated capacity remains 50 VA in either configuration, and the connected load must not exceed the permitted winding or overall transformer ratings.
The WV50P7S7 has a specified 15% voltage regulation, which is an important consideration when selecting the transformer for voltage-sensitive equipment. Secondary voltage may be higher under light-load or no-load conditions than at rated load, so connected devices should be suitable for the expected voltage variation. Its Class E insulation, compact dimensions and associated EPH 1 or EPN 1 enclosure options make it a practical component for industrial control panel applications where space and voltage flexibility are important.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 50 VA | |
|---|---|---|
| Primary Voltage | 0/380/400/420/440/460/480V | |
| Secondary Voltage | 0/24V + 0/24V | |
| Phase | Single Phase | |
| Manufacturer | ETE | |
| Series | WV Wide-Input-Voltage Stock Control Transformers | |
| Model | WV50P7S7 | |
| Product type | Wide-input-voltage industrial control transformer | |
| Transformer type | Single-phase | |
| Primary terminal markings | 0/380/400/420/440/460/480 V | |
| Nominal primary voltage options | 380/400/420/440/460/480 V AC | |
| Secondary terminal markings | 0/24 V + 0/24 V | |
| Secondary winding arrangement | Dual 24 V AC windings | |
| Parallel output connection | 24 V AC | |
| Series output connection | 48 V AC | |
| Rated apparent power | 50 VA total | |
| Insulation class | E | |
| Voltage regulation | 15% | |
| Mounting type | Electrical panel / chassis installation | |
| Length | 75 mm | |
| Width | 65 mm | |
| Height | 88 mm | |
| Dimensions (L × W × H) | 75 × 65 × 88 mm | |
| Weight | 1 kg | |
| Enclosure reference | EPH 1 or EPN 1 | |
| Product range reference | ETE Stock Control Transformer Range, March 2026 |
The ETE WV50P7S7 is a 50 VA single-phase wide-input-voltage control transformer used to provide isolated 24 V or 48 V AC supplies for compatible industrial control circuits, machinery, relays and automation equipment.
The transformer has a total rated apparent power of 50 VA. This rating applies to the transformer as a whole and must not be interpreted as 50 VA available independently from each secondary winding.
The transformer has primary terminals marked 0/380/400/420/440/460/480 V, providing nominal input connections for 380 V, 400 V, 420 V, 440 V, 460 V and 480 V AC supplies.
The WV50P7S7 has two secondary windings marked 0/24 V + 0/24 V. They can be connected in parallel to provide 24 V AC or in series to provide 48 V AC, using the correct winding connections.
For 24 V AC, the two 24 V secondary windings are connected in parallel with matching polarity. For 48 V AC, they are connected in series with additive polarity. All wiring must follow the manufacturer's terminal identification and connection instructions.
The transformer has Class E insulation, providing a defined thermal insulation classification for industrial electrical equipment operated within the manufacturer's specified limits.
The transformer has a specified 15% voltage regulation. This indicates that the secondary voltage can vary between no-load and rated-load conditions, which should be considered when selecting connected control equipment.
The transformer measures 75 × 65 × 88 mm (length × width × height) and weighs 1 kg, making it suitable for compact industrial control panel installations.
The manufacturer's associated enclosure references are EPH 1 or EPN 1. The appropriate enclosure should be selected according to the required installation protection, mounting arrangement, ventilation and wiring requirements.
Yes. The 50 VA rated capacity can support multiple compatible control devices, provided their combined apparent power, starting demands and operating requirements remain within the transformer's total rating and the permitted secondary winding limits.
ETE WV wide-input-voltage control transformers provide flexible voltage transformation for industrial machinery, electrical control panels and automation systems. Combining 50 VA capacity, six nominal primary voltage options, dual 24 V secondary windings and selectable 24 V or 48 V AC output configurations, the ETE WV50P7S7 offers a compact and versatile solution for industrial control power applications.