ETE WV1000P8S8 Wide Input Voltage Control Transformer 1000VA 0/500/550/600/690V to 0/110/120V + 0/110/120V

ETE WV1000P8S8 Wide Input Voltage Control Transformer 1000VA 0/500/550/600/690V to 0/110/120V + 0/110/120V

ETE WV1000P8S8 is a 1000 VA single-phase wide-input-voltage control transformer with selectable 500/550/600/690 V AC primary taps, dual 0/110/120 V secondary windings configurable for 110/120 V parallel or 220/240 V series output, Class E insulation and 4% voltage regulation.

SKU: WV1000P8S8MPN: WV1000P8S8
Price
List Price £170.70 ex VAT
Your Price (ex VAT) Save 25%
£128.03 25% OFF
You save £42.68 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £128.03
Trade pricing is personalised to your account

Manufacturer Lead Time

£128.03

Why Choose the ETE WV1000P8S8 1000 VA Wide-Input-Voltage Control Transformer?

The ETE WV1000P8S8 is a versatile 1000 VA (1 kVA) single-phase wide-input-voltage control transformer designed for industrial electrical control panels, machinery, switchgear and automation systems. Part of the ETE WV wide-input-voltage control transformer range, it combines multiple high-voltage primary taps with configurable dual secondary windings, providing flexible AC voltage conversion for industrial installations requiring a higher-capacity control power supply.

The WV1000P8S8 features a 0/500/550/600/690 V primary terminal arrangement, supporting compatible 500, 550, 600 and 690 V AC supplies. Its two 0/110/120 V secondary windings can be connected in parallel for 110 V or 120 V AC, or in series for 220 V or 240 V AC. This flexibility makes the transformer suitable for industrial control equipment with different operating voltage requirements.

With a rated apparent power of 1000 VA (1 kVA), Class E insulation and 4% voltage regulation, the WV1000P8S8 provides a practical solution for appropriately rated industrial control circuits. Its dimensions of 150 × 125 × 145 mm and weight of 9.8 kg make it suitable for installation in electrical control cabinets with adequate mounting space and mechanical support. The specified enclosure reference is EPN 3.

Key Advantages

  • 1000 VA (1 kVA) rated capacity for industrial control, signalling and automation applications.
  • Wide primary voltage selection covering 500, 550, 600 and 690 V AC.
  • Dual secondary windings provide flexible series and parallel output configurations.
  • 110 V or 120 V AC parallel output for compatible industrial control devices.
  • 220 V or 240 V AC series output for higher-voltage control circuits.
  • 4% voltage regulation provides a defined secondary voltage regulation characteristic.
  • Class E insulation provides a specified thermal insulation classification.
  • 150 × 125 × 145 mm dimensions support integration into appropriately sized industrial electrical cabinets.
  • Single-phase construction suitable for industrial machinery and electrical control assemblies.
  • EPN 3 enclosure reference assists with selecting suitable protective housing.

Key Features

  • ETE WV wide-input-voltage control transformer series.
  • 1000 VA (1 kVA) rated apparent power.
  • Single-phase transformer configuration.
  • Primary terminals: 0/500/550/600/690 V.
  • Selectable primary voltages: 500, 550, 600 and 690 V AC.
  • Secondary terminals: 0/110/120 V + 0/110/120 V.
  • Secondary winding arrangement: Dual windings configurable in series or parallel.
  • Parallel secondary output: 110 V or 120 V AC.
  • Series secondary output: 220 V or 240 V AC.
  • Voltage regulation: 4%.
  • Insulation class: E.
  • Dimensions: 150 × 125 × 145 mm.
  • Weight: 9.8 kg.
  • Enclosure reference: EPN 3.

Flexible 500–690 V Input with 110/120 V or 220/240 V AC Output

The ETE WV1000P8S8 is designed for industrial control installations where the available primary supply voltage may differ between machines, facilities or electrical systems. Its selectable primary terminals support 500, 550, 600 and 690 V AC, allowing the transformer to be configured for several compatible industrial electrical supplies.

The transformer incorporates two secondary windings, each with 0/110/120 V terminals. Connecting matching secondary winding taps in parallel with the correct polarity provides 110 V or 120 V AC. Connecting the windings in series with the correct additive polarity provides 220 V or 240 V AC. All winding connections must follow ETE's instructions to ensure correct voltage selection and safe operation.

Based on its 1000 VA rating, the theoretical full-load secondary current is approximately 9.09 A at 110 V AC, 8.33 A at 120 V AC, 4.55 A at 220 V AC or 4.17 A at 240 V AC. These calculated values assume the full rated apparent power is available in the selected configuration. Actual permissible winding currents and loading requirements must follow ETE's specifications.

The specified 4% voltage regulation means secondary voltage variation between operating load conditions should be considered when selecting connected equipment. Sensitive devices requiring tightly regulated supplies may need additional voltage regulation. Correct primary tap selection, secondary winding polarity, suitable circuit protection, conductor sizing and appropriate installation clearances are particularly important when working with primary supplies up to 690 V AC.

Typical Applications

  • Industrial electrical control panels and switchgear assemblies.
  • Control circuits supplied from 500, 550, 600 or 690 V AC systems.
  • 110 V and 120 V AC relay and contactor control circuits.
  • 220 V and 240 V AC industrial control equipment.
  • OEM machinery designed for different industrial supply voltages.
  • Industrial process control and automation installations.
  • Motor control centres and machinery control cabinets.
  • Industrial signalling and monitoring equipment.
  • Electrical assemblies requiring selectable isolated AC control voltages.
  • Replacement of existing control transformers with matching electrical and mechanical specifications.

Technical Specifications

Tick the specs you need, then view products that match.

Rated Power (VA) 1000 VA
Primary Voltage 0/500/550/600/690V
Secondary Voltage 0/110/120V + 0/110/120V
Phase Single Phase
Manufacturer ETE
Series WV Wide-Input-Voltage Control Transformers
Model WV1000P8S8
Product type Wide-input-voltage control transformer
Rated apparent power 1000 VA (1 kVA)
Number of phases Single-phase
Primary terminal arrangement 0/500/550/600/690 V
Primary voltage options 500/550/600/690 V AC
Secondary terminal arrangement 0/110/120 V + 0/110/120 V
Secondary winding configuration Dual windings, series or parallel
Parallel secondary output 110/120 V AC
Series secondary output 220/240 V AC
Voltage regulation 4%
Insulation class E
Length 150 mm
Width 125 mm
Height 145 mm
Dimensions (L × W × H) 150 × 125 × 145 mm
Weight 9.8 kg
Enclosure reference EPN 3
Product range reference ETE Stock Control Transformer Range, March 2026

Frequently Asked Questions

What is the ETE WV1000P8S8 used for?

The ETE WV1000P8S8 is a 1000 VA single-phase wide-input-voltage control transformer designed to convert compatible 500–690 V AC supplies into selectable 110/120 V or 220/240 V AC outputs for industrial control circuits, machinery and automation equipment.

What primary voltages does the WV1000P8S8 support?

The transformer features a 0/500/550/600/690 V primary terminal arrangement, supporting selectable 500, 550, 600 and 690 V AC input connections.

What secondary voltages can the ETE WV1000P8S8 provide?

The transformer provides 110 V or 120 V AC when its secondary windings are connected in parallel, or 220 V or 240 V AC when they are connected in series.

What is the power rating of the WV1000P8S8?

The transformer has a rated apparent power of 1000 VA (1 kVA), making it suitable for appropriately rated industrial control, signalling and automation applications.

How should the secondary windings be connected in series or parallel?

The two 0/110/120 V secondary windings must be connected according to ETE's wiring instructions. Parallel operation requires matching winding voltages and correct polarity, while series operation requires the correct additive-polarity connection to obtain 220 V or 240 V AC.

What output current can the WV1000P8S8 provide?

Based on the 1000 VA rating, the theoretical full-load secondary current is approximately 9.09 A at 110 V AC, 8.33 A at 120 V AC, 4.55 A at 220 V AC or 4.17 A at 240 V AC, assuming the full rating is available in the selected configuration. Actual permissible loading must follow ETE's specifications.

What does 4% voltage regulation mean?

The specified 4% voltage regulation describes the transformer's secondary voltage variation between load conditions. Connected equipment should tolerate the resulting voltage variation, and additional regulation may be required for voltage-sensitive devices.

What are the dimensions and weight of the WV1000P8S8?

The transformer measures 150 mm long × 125 mm wide × 145 mm high and weighs 9.8 kg, making it suitable for appropriately sized industrial control cabinets with adequate mechanical support.

What insulation class and enclosure reference does the WV1000P8S8 have?

The transformer features Class E insulation and specifies EPN 3 as its enclosure reference. The appropriate enclosure and mounting arrangement should be selected according to installation requirements.

A Practical Choice for Industrial Control Panel Builders

The ETE WV1000P8S8 combines a 1000 VA (1 kVA) rating, four selectable high-voltage primary taps, configurable 110/120 V and 220/240 V AC secondary outputs, Class E insulation and 4% voltage regulation. Its wide-input-voltage design makes it a practical choice for industrial control panel builders, OEM machinery manufacturers and electrical maintenance engineers requiring flexible, higher-capacity AC control voltage conversion.