ETE MV750P2S2 is a 750 VA single-phase multi-voltage control transformer with 20/0/380/420 V primary terminals, tapped 10/0/220/240 V secondary terminals requiring ETE confirmation of the 10 V adjustment connections, Class E insulation, 4% voltage regulation and an EPN 3 enclosure reference.
£101.10
The ETE MV750P2S2 is a 750 VA single-phase multi-voltage control transformer designed for industrial electrical installations requiring selectable primary connections and a tapped secondary winding. Part of the ETE MV multi-voltage control transformer series, it features 20/0/380/420 V primary terminals and 10/0/220/240 V secondary terminals, providing a versatile solution for industrial control panels, machinery and automation equipment.
The transformer incorporates nominal 380 V and 420 V primary terminal selections, allowing integration into compatible industrial supply systems. Its secondary winding includes 220 V and 240 V terminal markings, together with a 10 V adjustment tap. The precise secondary output connection arrangement must follow the ETE datasheet, and the correct adjustment tap connections must be confirmed with ETE before installation.
With a rated capacity of 750 VA (0.75 kVA), the MV750P2S2 is suitable for supplying compatible AC control loads within its specified apparent power rating. Its 4% voltage regulation provides a useful specification for assessing secondary voltage variation between load conditions, while Class E insulation provides a defined thermal insulation classification.
Measuring 150 × 108 × 145 mm and weighing 7.6 kg, the ETE MV750P2S2 can be incorporated into appropriately designed industrial electrical assemblies. Its associated enclosure reference is EPN 3, supporting enclosure selection and control panel planning.
The ETE MV750P2S2 is designed for industrial electrical installations requiring a dedicated control transformer with multiple voltage terminal selections. Its 20/0/380/420 V primary terminal arrangement includes nominal 380 V and 420 V terminal markings, allowing the appropriate input connection to be selected in accordance with ETE's instructions. The correct terminal arrangement should always be verified before the transformer is energised.
The secondary winding features 10/0/220/240 V terminal markings. These provide a tapped secondary arrangement incorporating nominal 220 V and 240 V positions together with a 10 V adjustment tap. However, the complete permissible output connection arrangements cannot be established from the terminal markings alone. ETE's datasheet must be followed, and the correct use of the 10 V adjustment tap must be confirmed with ETE.
At its rated 750 VA capacity, the calculated nominal secondary current is approximately 3.41 A at 220 V AC or 3.13 A at 240 V AC, assuming the corresponding output connection is approved by ETE. These figures are calculated from apparent power divided by nominal voltage and are not separately verified manufacturer current ratings. The transformer must not be loaded beyond its overall 750 VA rating or any additional winding and terminal limits specified by the manufacturer.
The specified 4% voltage regulation is relevant when assessing secondary voltage variation between load conditions. Actual output voltage depends on the incoming supply, selected primary and secondary connections and connected load. Control relays, contactor coils and other inductive equipment may introduce changing loads or short-duration inrush requirements, so both continuous apparent power and operating characteristics should be considered when selecting the transformer.
With Class E insulation, dimensions of 150 × 108 × 145 mm and a weight of 7.6 kg, the MV750P2S2 can be incorporated into appropriately engineered industrial control assemblies. Its EPN 3 enclosure reference assists with enclosure planning. Suitable mechanical support, circuit protection, conductor sizing, ventilation and electrical clearances should be provided in accordance with the manufacturer's installation instructions and applicable electrical requirements.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 750 VA | |
|---|---|---|
| Primary Voltage | 20/0/380/420V | |
| Secondary Voltage | 10/0/220/240V | |
| Phase | Single Phase | |
| Manufacturer | ETE | |
| Product series | MV Multi-Voltage Control Transformers | |
| Manufacturer part number | MV750P2S2 | |
| Product type | Multi-voltage control transformer | |
| Transformer configuration | Single-phase | |
| Rated apparent power | 750 VA | |
| Rated capacity | 0.75 kVA | |
| Primary terminals | 20/0/380/420 V | |
| Primary voltage terminal markings | 380 V and 420 V | |
| Secondary terminals | 10/0/220/240 V | |
| Secondary voltage terminal markings | 220 V and 240 V | |
| Adjustment tap | 10 V | |
| Secondary output connection | Tapped output per ETE datasheet | |
| Adjustment tap connection requirement | Confirm correct terminal connections with ETE | |
| Calculated nominal secondary current at 220 V | Approximately 3.41 A at 750 VA, subject to confirmation of the correct output connection | |
| Calculated nominal secondary current at 240 V | Approximately 3.13 A at 750 VA, subject to confirmation of the correct output connection | |
| Calculated ideal primary current at 380 V | Approximately 1.97 A at 750 VA, excluding transformer losses and magnetising current | |
| Calculated ideal primary current at 420 V | Approximately 1.79 A at 750 VA, excluding transformer losses and magnetising current | |
| Insulation class | E | |
| Voltage regulation | 4% | |
| Length | 150 mm | |
| Width | 108 mm | |
| Height | 145 mm | |
| Dimensions (L × W × H) | 150 × 108 × 145 mm | |
| Weight | 7.6 kg | |
| Enclosure reference | EPN 3 | |
| Product range | ETE Stock Control Transformers | |
| Catalogue reference | ETE Stock Control Transformer Range, March 2026 |
The ETE MV750P2S2 is a 750 VA single-phase multi-voltage control transformer designed to supply compatible industrial control circuits, machinery and automation equipment using its specified primary and tapped secondary connections.
The transformer has a rated apparent power of 750 VA (0.75 kVA). Connected loads must remain within this rating and any additional manufacturer-specified winding or terminal limits.
The transformer features 20/0/380/420 V primary terminals, including nominal 380 V and 420 V terminal markings. The correct primary connection must follow ETE's instructions.
The transformer has 10/0/220/240 V secondary terminals, incorporating 220 V and 240 V terminal markings together with a 10 V adjustment tap.
The secondary winding includes a 220 V terminal marking. The correct output connection arrangement must be established from the ETE datasheet before using the transformer to supply a nominal 220 V AC load.
The secondary winding includes a 240 V terminal marking. The correct output connection arrangement must be established from the ETE datasheet before using the transformer to supply a nominal 240 V AC load.
The 10 V adjustment tap provides an additional connection facility within the tapped winding arrangement. Its correct use and terminal connections must be confirmed with ETE; the terminal markings alone should not be used to assume a particular adjustment configuration.
The secondary output must be connected according to the ETE datasheet. The supplied specification identifies a tapped output arrangement, and ETE should be consulted to confirm the correct terminal connections, particularly those involving the 10 V adjustment tap.
At the rated 750 VA capacity and a nominal 220 V AC output, the calculated current is approximately 3.41 A. This is a theoretical calculation, not a separately verified manufacturer current rating, and assumes ETE confirms the corresponding output connection.
At the rated 750 VA capacity and a nominal 240 V AC output, the calculated current is approximately 3.13 A. This is a theoretical calculation, not a separately verified manufacturer current rating, and assumes ETE confirms the corresponding output connection.
The MV750P2S2 has a specified 4% voltage regulation. Transformer voltage regulation describes the change in secondary voltage between defined load conditions, so connected equipment should have suitable operating voltage tolerance.
The transformer uses Class E insulation, providing a defined thermal insulation classification for its winding insulation system.
The transformer measures 150 × 108 × 145 mm (L × W × H) and weighs 7.6 kg. These details assist with electrical panel layout, mechanical support and installation planning.
The associated enclosure reference is EPN 3. The enclosure arrangement and its suitability for the intended installation should be confirmed before selection.
Before installation, confirm the correct 20/0/380/420 V primary connections and the 10/0/220/240 V secondary connections. The correct use of the 10 V adjustment tap must be confirmed with ETE. Check the connected load against the 750 VA rating and provide suitable circuit protection, conductor sizing, mounting, ventilation and electrical clearances.
ETE MV multi-voltage control transformers offer a practical solution for industrial electrical applications requiring selectable primary connections and tapped secondary outputs. With 20/0/380/420 V primary terminals, 10/0/220/240 V secondary terminals, a 750 VA rating, Class E insulation and 4% voltage regulation, the MV750P2S2 provides electrical panel builders, machinery manufacturers and automation engineers with a versatile option for industrial control power, subject to confirmation of the correct adjustment tap connections with ETE.