ETE MV6250P2S1 is a 6250 VA single-phase multi-voltage control transformer with 20/0/380/420 V primary terminals, selectable 55 V or 110 V AC secondary taps, Class F insulation, 3% voltage regulation and an EPN 7 enclosure reference.

SKU: MV6250P2S1MPN: MV6250P2S1
Price
List Price £674.70 ex VAT
Your Price (ex VAT) Save 25%
£506.03 25% OFF
You save £168.68 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £506.03
Trade pricing is personalised to your account

Manufacturer Lead Time

£506.03

Why Choose the ETE MV6250P2S1 6250 VA Multi-Voltage Control Transformer?

The ETE MV6250P2S1 is a high-capacity 6250 VA (6.25 kVA) single-phase multi-voltage control transformer designed for industrial electrical control systems, machinery, switchgear and automation equipment. Part of the ETE MV stock control transformer range, it provides flexible primary voltage selection and a tapped secondary winding for applications requiring reliable AC voltage conversion and electrical isolation.

The MV6250P2S1 features a 20/0/380/420 V primary terminal arrangement for compatible 380 V and 420 V AC supplies. Its 0/55/110 V secondary terminals provide selectable 55 V or 110 V AC outputs, making it suitable for industrial equipment operating at different control voltages. A 20 V primary adjustment tap provides additional connection flexibility, with the correct terminal arrangements to be confirmed with ETE.

With a substantial 6250 VA power rating, Class F insulation and 3% voltage regulation, the MV6250P2S1 is designed for demanding industrial installations. Measuring 245 × 250 × 230 mm and weighing 58 kg, it requires appropriate mechanical support and installation space. The specified enclosure reference is EPN 7.

Key Advantages

  • 6250 VA (6.25 kVA) rated capacity for high-demand industrial control power applications.
  • 380 V and 420 V AC primary voltage options for compatible industrial electrical supplies.
  • Selectable 55 V or 110 V AC secondary output for different control circuit requirements.
  • 20 V primary adjustment tap provides additional connection flexibility.
  • 3% voltage regulation supports consistent secondary voltage performance under changing loads.
  • Class F insulation provides dependable thermal insulation performance.
  • Single-phase construction suitable for industrial electrical panels and machinery control systems.
  • Tapped secondary winding allows voltage selection without requiring separate transformers.
  • Provides electrical isolation between primary and secondary circuits.
  • EPN 7 enclosure reference assists with selecting a compatible protective enclosure.

Key Features

  • ETE MV multi-voltage control transformer series.
  • 6250 VA (6.25 kVA) rated apparent power.
  • Single-phase transformer configuration.
  • Primary terminals: 20/0/380/420 V.
  • Primary supply options: 380 V or 420 V AC.
  • Primary adjustment: 20 V tap; confirm connections with ETE.
  • Secondary terminals: 0/55/110 V.
  • Secondary output options: 55 V or 110 V AC.
  • Secondary connection: Tapped output winding.
  • Voltage regulation: 3%.
  • Insulation class: F.
  • Dimensions: 245 × 250 × 230 mm.
  • Weight: 58 kg.
  • Enclosure reference: EPN 7.

High-Capacity 55 V and 110 V AC Control Power from 380/420 V Supplies

Industrial control transformers provide voltage conversion and electrical isolation for control circuits and compatible electrical equipment. The ETE MV6250P2S1 is designed to operate from suitable 380 V or 420 V AC primary supplies and deliver a selectable 55 V or 110 V AC secondary output. This makes it suitable for industrial installations where a higher-voltage AC supply must be converted to a lower control voltage.

The transformer uses a 0/55/110 V tapped secondary winding, allowing the required voltage to be selected using the appropriate terminals. Its 20/0/380/420 V primary arrangement incorporates a 20 V adjustment tap. The correct use of this tap and the associated terminal connections must be confirmed with ETE before energising the transformer.

At 110 V AC, the theoretical full-load secondary current calculated from the 6250 VA rating is approximately 56.8 A. At 55 V AC, the mathematical equivalent of the full rated power is approximately 113.6 A; however, the actual permissible loading of the 55 V tap must be verified with ETE. A tapped secondary winding must not automatically be assumed to provide the full transformer rating at every voltage selection.

The transformer's 3% voltage regulation supports consistent output performance, while its Class F insulation system provides thermal insulation suitable for industrial transformer applications. Its 58 kg weight requires appropriate lifting, handling and mounting arrangements, together with suitable electrical protection, conductor sizing and ventilation.

Typical Applications

  • Industrial electrical control panels and switchgear assemblies.
  • 110 V AC control circuits supplied from compatible 380/420 V AC systems.
  • 55 V AC control and signalling circuits requiring a compatible tapped supply.
  • High-capacity industrial machinery control systems.
  • OEM manufacturing machinery and production equipment.
  • Motor control centres and electrical control cabinets.
  • Industrial process control and automation installations.
  • Electrical voltage conversion for compatible industrial control equipment.
  • Isolated AC control power supplies within industrial electrical installations.
  • Replacement of existing control transformers with matching electrical and mechanical specifications.

Technical Specifications

Tick the specs you need, then view products that match.

Rated Power (VA) 6250 VA
Primary Voltage 20/0/380/420V
Secondary Voltage 0/55/110V
Phase Single Phase
Manufacturer ETE
Series MV Multi-Voltage Control Transformers
Model MV6250P2S1
Product type Multi-voltage control transformer
Rated apparent power 6250 VA (6.25 kVA)
Number of phases Single-phase
Primary terminal arrangement 20/0/380/420 V
Primary voltage options 380/420 V AC
Primary adjustment tap 20 V; confirm connections with ETE
Secondary terminal arrangement 0/55/110 V
Secondary output voltage 55 V or 110 V AC
Secondary connection type Tapped output winding
Voltage regulation 3%
Insulation class F
Length 245 mm
Width 250 mm
Height 230 mm
Dimensions (L × W × H) 245 × 250 × 230 mm
Weight 58 kg
Enclosure reference EPN 7
Product range reference ETE Stock Control Transformer Range, March 2026

Frequently Asked Questions

What is the ETE MV6250P2S1 used for?

The ETE MV6250P2S1 is a high-capacity single-phase industrial control transformer designed to convert compatible 380 V or 420 V AC supplies into selectable 55 V or 110 V AC outputs for machinery, switchgear and automation control circuits.

What is the power rating of the ETE MV6250P2S1?

The transformer has a rated apparent power of 6250 VA (6.25 kVA), making it suitable for industrial applications requiring substantial AC control power.

What primary voltage does the MV6250P2S1 support?

The transformer features a 20/0/380/420 V primary terminal arrangement for compatible 380 V and 420 V AC supplies. It also includes a 20 V primary adjustment tap, with connections to be confirmed with ETE.

Can the ETE MV6250P2S1 provide both 55 V and 110 V AC?

Yes. Its 0/55/110 V tapped secondary winding allows selection of either 55 V or 110 V AC using the appropriate terminals.

What is the purpose of the 20 V primary adjustment tap?

The 20 V primary adjustment tap provides an additional connection point within the multi-voltage primary arrangement. Its correct use and terminal connections must be confirmed with ETE before energising the transformer.

What output current can the MV6250P2S1 provide?

At its 6250 VA rating, the theoretical full-load secondary current at 110 V AC is approximately 56.8 A. The permissible current at the 55 V tap must be confirmed with ETE because the tapped winding may have a different current limitation.

What are the dimensions and weight of the MV6250P2S1?

The transformer measures 245 mm long × 250 mm wide × 230 mm high and weighs 58 kg. Suitable lifting, handling and mounting arrangements should be provided.

What insulation class and voltage regulation does this transformer have?

The MV6250P2S1 features Class F insulation and 3% voltage regulation, supporting dependable operation in industrial electrical installations.

Which enclosure is specified for the ETE MV6250P2S1?

The specified enclosure reference is EPN 7, identifying the corresponding ETE enclosure size for installations requiring additional protective housing.

Trusted by Industrial Control Panel Builders

ETE MV multi-voltage control transformers provide dependable voltage conversion solutions for industrial electrical installations. The MV6250P2S1 combines a substantial 6250 VA rating, flexible 380/420 V primary connections, selectable 55/110 V secondary taps, Class F insulation and 3% voltage regulation, making it a practical choice for industrial control panel builders, machinery manufacturers and electrical maintenance engineers.