ETE MV50P2S1 is a 50 VA single-phase multi-voltage control transformer with 20/0/380/420 V primary terminals, selectable 55 V or 110 V AC secondary taps, a 20 V primary adjustment tap requiring ETE connection confirmation, Class E insulation and 15% voltage regulation.
£21.23
The ETE MV50P2S1 is a 50 VA single-phase multi-voltage control transformer designed for industrial electrical installations requiring flexible primary voltage connections and selectable secondary output voltages. Part of the ETE MV multi-voltage transformer range, it features 20/0/380/420 V primary terminals and 0/55/110 V secondary terminals, allowing the selection of a nominal 55 V AC or 110 V AC output using the appropriate secondary tap.
Its multi-voltage arrangement makes the MV50P2S1 a practical solution for electrical panel builders, machinery manufacturers and maintenance engineers working with compatible industrial control systems. The transformer provides dedicated AC voltage transformation for control circuits, signalling equipment and other devices requiring a suitable 55 V AC or 110 V AC supply.
The transformer includes a 20 V primary adjustment tap, which provides an additional connection facility within the primary winding arrangement. The correct use of this adjustment tap and the required primary terminal connections must be confirmed with ETE before installation. The terminal markings alone should not be used to infer an unverified connection arrangement.
With Class E insulation, a specified 15% voltage regulation, dimensions of 75 × 65 × 88 mm and a weight of approximately 1 kg, the MV50P2S1 provides a compact control transformer option. The associated enclosure references are EPH 1 or EPN 1, allowing suitable enclosure arrangements to be identified for the application.
The ETE MV50P2S1 provides a flexible solution for industrial installations requiring selectable control voltages from a single transformer. Its 0/55/110 V secondary terminal arrangement allows an appropriately connected circuit to receive a nominal 55 V AC or 110 V AC supply. This can be useful when designing or maintaining machinery with different control voltage requirements.
The transformer's 50 VA rated capacity is suitable for compatible low-power control equipment, including selected relay coils, indication circuits and signalling devices. At the rated apparent power, the calculated secondary current is approximately 0.91 A at 55 V or 0.45 A at 110 V. These values are calculated from the transformer rating and nominal output voltages; they are not separately verified manufacturer current ratings. The 50 VA capacity is the overall transformer rating and must not be interpreted as 50 VA independently available from each tap at the same time.
The 20 V primary adjustment tap is an important feature of the MV50P2S1. Because its terminal arrangement includes 20/0/380/420 V markings, installers must follow the correct manufacturer-defined wiring configuration. Confirm the appropriate connections with ETE before energising the transformer, particularly where the adjustment tap is being considered. Incorrect primary connections can result in unsuitable secondary voltages or equipment damage.
The specified 15% voltage regulation is relevant when assessing output voltage variation between operating conditions. The actual secondary voltage can vary with supply voltage and connected load, so equipment with narrow operating voltage tolerances should be checked for compatibility. This is particularly important for low-power transformers supplying contactors, relays or electronic equipment with specific voltage requirements.
With its Class E insulation, compact dimensions and EPH 1 or EPN 1 enclosure references, the MV50P2S1 can be incorporated into suitably engineered electrical installations. Appropriate mounting, primary and secondary circuit protection, conductor sizing, ventilation and electrical clearances must be provided in accordance with the manufacturer's instructions and applicable installation requirements.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 50 VA | |
|---|---|---|
| Primary Voltage | 20/0/380/420V | |
| Secondary Voltage | 0/55/110V | |
| Phase | Single Phase | |
| Manufacturer | ETE | |
| Series | MV Multi-Voltage Control Transformers | |
| Model | MV50P2S1 | |
| Product type | Multi-voltage control transformer | |
| Transformer configuration | Single-phase | |
| Rated apparent power | 50 VA | |
| Rated capacity | 0.05 kVA | |
| Primary terminal markings | 20/0/380/420 V | |
| Primary voltage positions | 380 V and 420 V | |
| Primary adjustment tap | 20 V | |
| Primary connection requirement | Confirm correct adjustment tap and supply connections with ETE | |
| Secondary terminal markings | 0/55/110 V | |
| Secondary output option 1 | 55 V AC | |
| Secondary output option 2 | 110 V AC | |
| Secondary output connection | 55 V or 110 V taps | |
| Calculated secondary current at 55 V | Approximately 0.91 A at 50 VA | |
| Calculated secondary current at 110 V | Approximately 0.45 A at 50 VA | |
| Insulation class | E | |
| Voltage regulation | 15% | |
| Length | 75 mm | |
| Width | 65 mm | |
| Height | 88 mm | |
| Dimensions (L × W × H) | 75 × 65 × 88 mm | |
| Weight | 1 kg | |
| Enclosure reference | EPH 1 or EPN 1 | |
| Product range | ETE Stock Control Transformers | |
| Catalogue reference | ETE Stock Control Transformer Range, March 2026 |
The ETE MV50P2S1 is a 50 VA single-phase multi-voltage control transformer used to provide a selectable nominal 55 V AC or 110 V AC secondary supply for compatible industrial control circuits, electrical panels and machinery.
The transformer has a rated apparent power of 50 VA (0.05 kVA). The connected load must remain within the transformer's overall rated capacity.
The transformer has 20/0/380/420 V primary terminals. These include a 20 V adjustment tap. The correct supply and adjustment tap connections must be confirmed with ETE before installation.
The transformer features 0/55/110 V secondary terminals and supports a nominal 55 V AC or 110 V AC output, depending on the selected secondary connection.
The 20 V primary adjustment tap provides an additional connection facility within the transformer's primary arrangement. Its correct use and wiring configuration must be confirmed with ETE; the terminal markings alone should not be used to assume a particular adjustment connection.
The transformer has 0/55/110 V secondary taps, but its specified output connection is 55 V or 110 V. Simultaneous loading of both taps should not be assumed without confirmation from ETE, and the total load must remain within the 50 VA rating.
At a nominal 55 V AC output, the calculated current corresponding to the 50 VA rating is approximately 0.91 A. This is a calculated value rather than a separately verified manufacturer current rating.
At a nominal 110 V AC output, the calculated current corresponding to the 50 VA rating is approximately 0.45 A. This is a calculated value rather than a separately verified manufacturer current rating.
The MV50P2S1 has a specified 15% voltage regulation. Transformer voltage regulation describes the change in secondary voltage between defined load conditions, so connected equipment should be selected with suitable voltage tolerance.
The transformer uses Class E insulation, providing a defined thermal insulation classification for its winding insulation system.
The transformer measures 75 × 65 × 88 mm (L × W × H) and weighs approximately 1 kg. These details assist with electrical panel layout and mechanical installation planning.
The associated enclosure references are EPH 1 or EPN 1. The appropriate enclosure arrangement and its suitability for the installation should be confirmed before selection.
Yes. The MV50P2S1 is a multi-voltage control transformer suitable for appropriately designed industrial control panels requiring a compatible 55 V AC or 110 V AC supply within its 50 VA capacity.
Before installation, confirm the correct 20/0/380/420 V primary connections and the use of the 20 V adjustment tap with ETE. Select the appropriate 55 V or 110 V secondary connection, check the total connected load against the 50 VA rating, and provide suitable circuit protection, wiring, mounting, ventilation and electrical clearances.
ETE MV multi-voltage control transformers offer a practical solution for industrial applications requiring flexible AC voltage transformation and selectable control voltages. With 20/0/380/420 V primary terminals, 55 V or 110 V secondary output options, a 50 VA rating, Class E insulation and a compact design, the MV50P2S1 provides electrical panel builders, machinery manufacturers and maintenance engineers with a versatile option for low-power industrial control circuits.