ETE MV500P1S3 is a 500 VA single-phase multi-voltage control transformer with 10/0/220/240 V primary terminals, dual 0/12 V secondary windings configurable for 12 V parallel or 24 V series output, a 10 V primary adjustment tap requiring ETE connection confirmation, Class E insulation and 8% voltage regulation.
£74.33
The ETE MV500P1S3 is a 500 VA single-phase multi-voltage control transformer designed for industrial electrical installations requiring flexible primary voltage connections and selectable low-voltage AC outputs. Part of the ETE MV multi-voltage control transformer range, it features 10/0/220/240 V primary terminals and two secondary windings, each marked 0/12 V.
The MV500P1S3 supports a nominal 12 V AC output with the secondary windings connected in parallel or a nominal 24 V AC output with the windings connected in series. This dual-output configuration makes it suitable for industrial control panels, machinery installations, OEM equipment and automation systems requiring compatible 12 V or 24 V AC control supplies.
Its primary winding incorporates nominal 220 V and 240 V AC terminal selections, together with a 10 V primary adjustment tap. This arrangement provides flexibility when integrating the transformer into compatible electrical installations. The correct use of the 10 V adjustment tap and its terminal connections must be confirmed with ETE before installation. The terminal markings alone should not be used to infer an unverified adjustment connection.
With Class E insulation, 8% voltage regulation, dimensions of 120 × 120 × 120 mm and a weight of 6.2 kg, the ETE MV500P1S3 offers a practical industrial control power solution. Its associated enclosure references are EPH 3 or EPN 2, supporting enclosure selection and electrical panel planning.
The ETE MV500P1S3 provides a practical solution for industrial installations requiring dedicated low-voltage AC control power from a compatible 220 V or 240 V primary supply. Its 10/0/220/240 V primary terminal arrangement offers selectable nominal input connections, while the two 0/12 V secondary windings provide flexible output configuration for different control circuit requirements.
When the secondary windings are connected correctly in parallel, the transformer provides a nominal 12 V AC output. Parallel operation combines the current contribution of the two windings while retaining the transformer's overall 500 VA rating. Correct winding polarity and matching voltage connections are essential because incorrect parallel wiring can produce damaging circulating currents. The manufacturer's approved connection arrangement should always be followed.
When connected correctly in series, the two secondary windings provide a nominal 24 V AC output. This configuration adds the voltages of the individual 12 V windings while retaining the overall transformer apparent power rating. Correct winding polarity is important because an incorrect series connection may result in voltage cancellation or an unsuitable output voltage.
At the rated 500 VA capacity, the calculated nominal secondary current is approximately 41.67 A at 12 V AC with the windings connected in parallel, or 20.83 A at 24 V AC with the windings connected in series. These figures are theoretical calculations based on apparent power divided by nominal voltage, rather than separately verified manufacturer current ratings. The 500 VA rating applies to the transformer as a whole and must not be interpreted as 500 VA independently available from each secondary winding.
The primary winding includes a 10 V adjustment tap, which must be connected only in accordance with ETE's confirmed instructions. The terminal markings do not establish every permissible voltage adjustment arrangement. Incorrect primary connections can result in unsuitable secondary voltages or damage to connected equipment, so the correct wiring configuration should be verified before the transformer is energised.
The specified 8% voltage regulation is relevant when evaluating secondary voltage variation under changing load conditions. Actual output voltage depends on the incoming supply, selected primary connections, secondary winding configuration and connected load. Control relays, contactor coils, solenoids and other inductive equipment may also introduce starting or inrush demands, so both continuous apparent power and short-duration operating requirements should be considered.
With Class E insulation, dimensions of 120 × 120 × 120 mm and a weight of 6.2 kg, the MV500P1S3 can be integrated into appropriately engineered industrial electrical assemblies. Its associated EPH 3 or EPN 2 enclosure references assist with enclosure planning. Suitable mounting, mechanical support, primary and secondary circuit protection, conductor sizing, ventilation and electrical clearances should be provided in accordance with ETE installation instructions and applicable electrical requirements.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 500 VA | |
|---|---|---|
| Primary Voltage | 10/0/220/240V | |
| Secondary Voltage | 0/12V + 0/12V | |
| Phase | Single Phase | |
| Manufacturer | ETE | |
| Product series | MV Multi-Voltage Control Transformers | |
| Manufacturer part number | MV500P1S3 | |
| Product type | Multi-voltage control transformer | |
| Transformer configuration | Single-phase | |
| Rated apparent power | 500 VA | |
| Rated capacity | 0.5 kVA | |
| Primary terminals | 10/0/220/240 V | |
| Nominal primary voltage options | 220 V or 240 V AC | |
| Primary adjustment tap | 10 V | |
| Primary adjustment connection requirement | Confirm correct terminal connections with ETE | |
| Number of secondary windings | 2 | |
| Secondary winding 1 terminals | 0/12 V | |
| Secondary winding 2 terminals | 0/12 V | |
| Parallel secondary output | 12 V AC | |
| Series secondary output | 24 V AC | |
| Secondary connection arrangement | 12 V parallel or 24 V series | |
| Calculated secondary current at 12 V parallel | Approximately 41.67 A at 500 VA | |
| Calculated secondary current at 24 V series | Approximately 20.83 A at 500 VA | |
| Calculated ideal primary current at 220 V | Approximately 2.27 A at 500 VA, excluding transformer losses and magnetising current | |
| Calculated ideal primary current at 240 V | Approximately 2.08 A at 500 VA, excluding transformer losses and magnetising current | |
| Insulation class | E | |
| Voltage regulation | 8% | |
| Length | 120 mm | |
| Width | 120 mm | |
| Height | 120 mm | |
| Dimensions (L × W × H) | 120 × 120 × 120 mm | |
| Weight | 6.2 kg | |
| Enclosure reference | EPH 3 or EPN 2 | |
| Product range | ETE Stock Control Transformers | |
| Catalogue reference | ETE Stock Control Transformer Range, March 2026 |
The ETE MV500P1S3 is a 500 VA single-phase multi-voltage control transformer used to provide a nominal 12 V AC or 24 V AC secondary supply for compatible industrial control circuits, machinery and automation equipment.
The transformer has a rated apparent power of 500 VA (0.5 kVA). This is the overall transformer rating and applies to the combined load on its secondary windings.
The transformer features 10/0/220/240 V primary terminals, including nominal 220 V and 240 V AC primary voltage selections. The correct connection arrangement must follow ETE instructions.
The 10 V primary adjustment tap provides an additional connection facility within the primary winding arrangement. Its correct use and wiring configuration must be confirmed with ETE before installation.
The transformer supports a nominal 12 V AC output with the secondary windings connected in parallel or a nominal 24 V AC output with the windings connected in series, using the manufacturer's specified wiring arrangements.
The MV500P1S3 has two secondary windings, each with 0/12 V terminals. The windings can be connected in the specified series or parallel configurations.
Yes. The two secondary windings can be connected in parallel to provide a nominal 12 V AC output. Correct winding polarity and matching voltage connections are essential, and the total load must remain within the 500 VA rating.
Yes. The two secondary windings can be connected in series to provide a nominal 24 V AC output. The correct series connection and winding polarity must be followed according to the manufacturer's instructions.
At the rated 500 VA capacity and a nominal 12 V AC parallel output, the calculated current is approximately 41.67 A. This is a calculated value rather than a separately verified manufacturer current rating.
At the rated 500 VA capacity and a nominal 24 V AC series output, the calculated current is approximately 20.83 A. This is a calculated value rather than a separately verified manufacturer current rating.
No. The 500 VA rating applies to the transformer as a whole. It should not be interpreted as 500 VA available independently from each 12 V winding. The manufacturer's specified winding connection and loading limits must be followed.
The MV500P1S3 has a specified 8% voltage regulation. Transformer voltage regulation describes the change in secondary voltage between defined load conditions, so connected equipment should have suitable operating voltage tolerance.
The transformer uses Class E insulation, providing a defined thermal insulation classification for its winding insulation system.
The transformer measures 120 × 120 × 120 mm (L × W × H) and weighs 6.2 kg. These details assist with electrical panel layout, mechanical support and installation planning.
The associated enclosure references are EPH 3 or EPN 2. The appropriate enclosure arrangement and its suitability for the installation should be confirmed before selection.
Before installation, confirm the correct 10/0/220/240 V primary connections and the use of the 10 V adjustment tap with ETE. Select the required 12 V parallel or 24 V series secondary arrangement, follow the manufacturer's winding connection instructions, check the connected load against the 500 VA rating, and provide suitable circuit protection, conductor sizing, mounting, ventilation and electrical clearances.
ETE MV multi-voltage control transformers provide a practical solution for industrial electrical applications requiring flexible primary connections and configurable low-voltage AC outputs. With 10/0/220/240 V primary terminals, dual 0/12 V secondary windings, selectable 12 V parallel or 24 V series output, a 500 VA rating and Class E insulation, the MV500P1S3 offers electrical panel builders, machinery manufacturers and automation engineers a versatile transformer option for industrial control power.