ETE MV400P1S1 is a 400 VA single-phase multi-voltage industrial control transformer with 10/0/220/240 V primary terminals and 0/55/110 V secondary terminals. It provides selectable nominal 55 V AC or 110 V AC output connections. The 10 V primary adjustment tap connections must be confirmed with ETE. Class E insulation, 8% voltage regulation, dimensions of 120 x 108 x 120 mm, weight of 5.5 kg and EPH 3 or EPN 2 enclosure references.
£63.98
The ETE MV400P1S1 is a 400 VA single-phase multi-voltage industrial control transformer featuring a tapped primary winding and selectable 55 V AC or 110 V AC secondary output. Part of the ETE MV stock control transformer range, this model offers a flexible AC control power solution for compatible industrial electrical panels, OEM machinery and automation equipment.
The transformer features 10/0/220/240 V primary terminals and 0/55/110 V secondary terminals. The secondary winding provides two nominal voltage options through its taps, allowing electrical designers to select the appropriate output for equipment requiring either 55 V AC or 110 V AC.
A distinguishing feature of the MV400P1S1 is its 10 V primary adjustment tap. This forms part of the tapped primary arrangement, but its precise function and approved terminal combinations must be confirmed with ETE. Do not infer the correct adjustment tap wiring from the terminal markings alone.
With a 400 VA apparent power rating, Class E insulation and 8% voltage regulation, the MV400P1S1 is a practical option for compatible industrial control loads. It measures 120 × 108 × 120 mm and weighs 5.5 kg.
The transformer is listed in the ETE Stock Control Transformer Range, March 2026, with specified enclosure references of EPH 3 or EPN 2.
The ETE MV400P1S1 incorporates a tapped primary winding with terminals marked 10/0/220/240 V. This arrangement is intended to support compatible AC supply configurations using the appropriate manufacturer-approved connections.
The 10 V primary adjustment tap is part of this arrangement. Its exact function and permissible terminal combinations must be verified with ETE before the transformer is energised. The terminal markings do not establish that the 10 V connection can be used as an independent supply input.
The secondary winding has terminals marked 0/55/110 V, providing nominal 55 V AC and 110 V AC output options. The selected output depends on the approved secondary tap connection and the correct primary supply arrangement.
These are alternative output taps on the specified secondary winding, not two independent 400 VA supplies. Any intended simultaneous use of multiple secondary taps, including permissible combined loading, should be confirmed with ETE.
The 55 V AC tap provides a nominal 55 V AC output for compatible control equipment. This option may be appropriate for specialist machinery, replacement installations or control circuits designed for 55 V AC operation.
The selected terminal connection and permissible tap loading should be checked against the manufacturer's technical documentation before a load is connected.
The 110 V AC tap provides a nominal 110 V AC output for compatible industrial control equipment, including suitably rated relays, contactors and auxiliary control circuits.
The output voltage, load demand and equipment operating tolerances must be assessed together to determine whether the transformer is suitable for a particular application.
The MV400P1S1 has a rated apparent power of 400 VA. For a single-phase transformer, the nominal current corresponding to a specified voltage can be calculated using:
Current (A) = Apparent power (VA) ÷ Secondary voltage (V)
At a nominal 55 V AC output:
400 VA ÷ 55 V = approximately 7.27 A
This is the mathematical current corresponding to the complete 400 VA rating at 55 V AC. It does not independently confirm the manufacturer's permissible current rating for the 55 V tap.
At a nominal 110 V AC output:
400 VA ÷ 110 V = approximately 3.64 A
This is the mathematical current corresponding to the complete 400 VA rating at 110 V AC.
The overall 400 VA rating must not be counted separately for each secondary tap. Actual loading should remain within the applicable manufacturer ratings, with allowance for the operating characteristics and inrush requirements of connected equipment.
The ETE MV400P1S1 has a specified 8% voltage regulation. Voltage regulation describes the change in transformer secondary voltage between no-load and rated-load conditions under defined conditions.
This characteristic matters because the actual secondary voltage may vary with the connected load. The nominal 55 V AC and 110 V AC outputs should not be interpreted as guaranteed constant voltages under all operating conditions.
When selecting the MV400P1S1 for voltage-sensitive equipment, engineers should consider both the transformer regulation characteristic and expected primary supply variation.
Before installing the ETE MV400P1S1, verify the available primary supply, intended secondary output voltage, total connected apparent power and correct terminal connections.
Primary wiring: The 10/0/220/240 V terminals include a 10 V adjustment tap. Confirm the correct connection arrangement with ETE before energising the transformer.
Secondary wiring: The 0/55/110 V terminals provide nominal 55 V AC or 110 V AC output options. Select the correct tap according to the manufacturer's wiring diagram and the connected equipment's voltage requirements.
Suitable primary and secondary circuit protection, conductor sizing, protective earthing where applicable, ventilation and secure mechanical mounting should be incorporated into the installation design.
The specified EPH 3 or EPN 2 enclosure references should be checked against the intended installation requirements. The references alone do not establish an enclosure's protection rating or confirm that an enclosure is included.
Tick the specs you need, then view products that match.
| Rated Power (VA) | 400 VA | |
|---|---|---|
| Primary Voltage | 10/0/220/240V | |
| Secondary Voltage | 0/55/110V | |
| Phase | Single Phase | |
| Brand | ETE | |
| Series | MV Multi-Voltage Stock Control Transformer Range | |
| Model / SKU | MV400P1S1 | |
| Product type | Industrial multi-voltage control transformer | |
| Transformer configuration | Tapped primary and tapped secondary | |
| Number of phases | Single-phase | |
| Rated apparent power | 400 VA | |
| Primary terminals | 10/0/220/240 V | |
| Primary adjustment tap | 10 V | |
| Primary connection note | Confirm connections with ETE | |
| Secondary terminals | 0/55/110 V | |
| Secondary output options | 55 V AC or 110 V AC | |
| Output connection | 55 V or 110 V taps | |
| Insulation class | E | |
| Voltage regulation | 8% | |
| Calculated current at nominal 55 V AC | Approximately 7.27 A, based on 400 VA | |
| Calculated current at nominal 110 V AC | Approximately 3.64 A, based on 400 VA | |
| Length | 120 mm | |
| Width | 108 mm | |
| Height | 120 mm | |
| Dimensions (L × W × H) | 120 × 108 × 120 mm | |
| Weight | 5.5 kg | |
| Enclosure reference | EPH 3 or EPN 2 | |
| Product range reference | ETE Stock Control Transformer Range, March 2026 |
The ETE MV400P1S1 is a 400 VA single-phase multi-voltage control transformer intended for compatible industrial control panels, OEM machinery and auxiliary electrical circuits. It features a tapped primary and selectable 55 V AC or 110 V AC secondary output.
The primary terminals are specified as 10/0/220/240 V. The correct connections, including the 10 V adjustment tap, must be confirmed with ETE.
The MV400P1S1 includes a 10 V primary adjustment tap as part of its tapped primary winding. Its exact use and approved terminal connections must be confirmed with ETE before installation.
The secondary terminals are specified as 0/55/110 V, providing nominal 55 V AC and 110 V AC output options using the appropriate connections.
Yes. The MV400P1S1 has a 55 V AC secondary tap. The correct terminal connection and permissible loading should be checked against ETE's technical documentation.
Yes. The MV400P1S1 has a 110 V AC secondary tap for compatible industrial control equipment. The correct terminal connection must follow the manufacturer's instructions.
The ETE MV400P1S1 has a rated apparent power of 400 VA. This is the overall transformer rating and must not be counted separately for each secondary tap.
At a nominal 55 V AC output, 400 VA corresponds mathematically to approximately 7.27 A. The permissible loading of the 55 V tap must still be verified against the manufacturer's documentation.
At a nominal 110 V AC output, 400 VA corresponds mathematically to approximately 3.64 A. This calculated value is for load assessment and does not replace the manufacturer's terminal ratings.
Do not assume that both secondary taps can supply independent loads simultaneously. Any permitted simultaneous loading and combined current limits must be confirmed with ETE.
The MV400P1S1 has a specified Class E insulation system.
The ETE MV400P1S1 has a specified 8% voltage regulation. This should be considered when assessing the operating voltage requirements of connected equipment.
The transformer measures 120 mm long, 108 mm wide and 120 mm high, with a specified weight of 5.5 kg.
The specified enclosure references are EPH 3 or EPN 2. Final enclosure selection should account for installation conditions, dimensions, ventilation and applicable electrical requirements.
No. The ETE MV400P1S1 is an AC control transformer providing nominal 55 V AC or 110 V AC output connections. Equipment requiring DC power needs a suitable DC power supply or appropriate rectification and conditioning equipment.
The MV400P1S1 has a 10/0/220/240 V primary terminal arrangement incorporating a 10 V adjustment tap. Confirming the ETE connection diagram helps prevent incorrect wiring and ensures the intended primary configuration is selected.
When specifying the ETE MV400P1S1, first confirm that the intended primary supply can be accommodated using the manufacturer's approved terminal arrangement. The 10 V adjustment tap must be connected only in accordance with ETE's instructions.
Next, confirm whether the connected equipment requires a nominal 55 V AC or 110 V AC output. Assess the total connected apparent power, any inrush requirements and the permissible loading of the selected secondary tap.
The transformer's 400 VA rating, 8% voltage regulation, Class E insulation, 120 × 108 × 120 mm dimensions and 5.5 kg weight should be considered during electrical and mechanical design.
The ETE MV400P1S1 combines a 400 VA rating with a tapped 10/0/220/240 V primary and selectable 55 V AC or 110 V AC secondary connections. Its Class E insulation, 8% voltage regulation and specified EPH 3 or EPN 2 enclosure references make it a practical option for compatible industrial control applications. Always confirm the 10 V primary adjustment tap connections with ETE.