Finder 093.01 plastic separator plate with 2 mm thickness for compatible Finder relay interface assemblies, designed to provide visual grouping, protective separation between different control voltages and protection of cut jumper links.
£0.845
The Finder 093.01 is a purpose-designed plastic separator plate for industrial relay interface modules, providing physical separation between adjacent interface assemblies in electrical control panels. As part of the Finder 93 Series relay socket accessories, it supports organised installation, electrical segregation and protection of exposed jumper link ends in industrial automation systems.
Designed for use with compatible Finder 93 Series sockets and 38 Series relay interfaces, the 093.01 features a 2 mm thickness that allows it to be installed alongside closely spaced interface modules. The separator is intended for placement at the beginning and end of interface groups and can also be used to distinguish neighbouring groups of relays visually.
The Finder 093.01 is particularly useful where adjacent PLC interface modules operate at different voltages. It provides protective separation in accordance with VDE 0106-101 when installed as specified by Finder and helps protect cut jumper links. Its compact design makes it suitable for industrial control cabinets where space efficiency and clearly separated electrical circuits are important.
Industrial relay interface modules are frequently installed in closely spaced groups within electrical control cabinets. These assemblies may include circuits operating at different control voltages, together with jumper links used to distribute common electrical connections. The Finder 093.01 plastic separator plate provides a physical barrier between compatible interface modules, supporting clear grouping and the protective separation of neighbouring circuits.
Finder specifies the 093.01 for use at the beginning and end of interface groups. It can also be used to separate groups visually and is required in specified arrangements involving different voltages or cut jumper links. Its 2 mm thickness allows integration into compact relay interface installations without requiring a large additional mounting space. Correct positioning in accordance with the applicable Finder interface documentation helps maintain the intended separation and protection.
| Manufacturer | Finder |
|---|---|
| Series | Finder 93 Series |
| Model | 093.01 |
| Manufacturer part number | 093.01 |
| Product type | Plastic separator plate |
| Product category | Relay Interface Accessories |
| Accessory function | Physical and protective separation of relay interfaces |
| Material | Plastic |
| Thickness | 2 mm |
| Compatible accessory series | Finder 93 Series |
| Related relay interface series | Finder 38 Series |
| Compatible socket examples | Finder 93.02 and 93.52 |
| Installation position | Beginning and end of compatible interface groups |
| Protective separation reference | VDE 0106-101 |
| Additional function | Protection of cut jumper links |
| Visual separation | Yes |
| Electrical supply | Not required |
| Installation environment | Electrical control panels and industrial automation cabinets |
| Country of origin | Italy |
| RoHS status | RoHS compliant |
The Finder 093.01 is a plastic separator plate used to provide physical and protective separation between compatible relay interface modules. It is also used to distinguish interface groups visually and protect cut jumper link ends.
The Finder 093.01 has a nominal thickness of 2 mm, allowing it to fit alongside compact relay interface modules in industrial control panels.
The Finder 093.01 belongs to the Finder 93 Series accessory range and is used with compatible relay interface assemblies, including selected Finder 38 Series interfaces and 93 Series sockets.
Yes. Finder specifies the 093.01 for protective separation of neighbouring PLC interfaces operating at different voltages, in accordance with VDE 0106-101 when correctly installed.
The separator is designed for installation at the beginning and end of a group of compatible relay interfaces. It can also be positioned between groups where visual or protective separation is required.
Yes. One of the specified functions of the Finder 093.01 plastic separator is to help protect the ends of cut jumper links used in compatible relay interface assemblies.
No. The Finder 093.01 is a passive plastic separator accessory. It does not contain switching contacts, a relay coil or other active electrical components.
No. The Finder 093.01 is a mechanical separation accessory and does not require electrical power or additional wiring.
Yes. The Finder 093.01 is designed for compatible industrial relay interface installations, including PLC control panels, factory automation cabinets and machinery control systems.
Finder 93 Series relay socket accessories support organised and dependable electrical interface installations. The Finder 093.01 plastic separator plate provides a compact solution for visual grouping, protective separation of neighbouring PLC interfaces and protection of cut jumper links, making it a practical accessory for industrial automation engineers, electrical panel builders and machine manufacturers.