Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Partex UCEF110 uninsulated cord end ferrule designed for crimp termination of a single 1 mm² flexible stranded copper conductor, featuring a 10 mm metal barrel for compatible electrical terminal connections.
£9.12
The Partex UCEF110 is a professional uninsulated cord end ferrule designed for terminating flexible stranded copper conductors with a nominal cross-sectional area of 1 mm². Featuring a 10 mm metal barrel length, this bootlace ferrule provides a practical solution for preparing conductor ends before insertion into compatible electrical terminals, helping achieve neat, consistent and organised wiring connections.
Part of the Partex uninsulated cord end ferrule range, the UCEF110 is designed to consolidate the individual strands of a flexible conductor into a compact crimped termination. Unlike insulated ferrules, this version does not feature a plastic entry collar, making it suitable for applications where an uninsulated ferrule configuration is preferred or required by the terminal design.
The 1 mm² conductor capacity and 10 mm barrel length make the UCEF110 a practical choice for electrical control panels, industrial automation equipment, machinery wiring and general electrical assembly. When installed using a compatible crimping tool, the ferrule helps prevent loose conductor strands and supports reliable termination practices in professional electrical installations.
Correct preparation of flexible stranded conductors is important for achieving consistent electrical connections. The Partex UCEF110 uninsulated cord end ferrule provides a practical method of preparing 1 mm² copper conductors for connection to compatible electrical terminals. Its crimpable metal barrel helps consolidate the conductor strands, producing a compact termination that can be inserted into an appropriately sized terminal opening.
Unlike insulated cord end ferrules, the UCEF110 does not include a plastic entry collar. This construction can be useful where installation space is restricted or where the terminal manufacturer specifies an uninsulated ferrule. However, the absence of an insulating collar means that the ferrule itself does not provide additional electrical insulation, and the installation must maintain the required insulation, clearances and protection against accidental contact.
For installation, the conductor should be stripped to a length appropriate for the 10 mm barrel and the receiving terminal's requirements. The exposed strands are inserted fully into the ferrule before the barrel is compressed using a compatible crimping tool. Correct crimping helps keep the strands together and supports consistent conductor positioning within the terminal.
The receiving terminal must be suitable for a 1 mm² conductor fitted with an uninsulated ferrule of the resulting crimped dimensions. Installers should follow the terminal manufacturer's conductor preparation instructions, tightening requirements and electrical ratings. A ferrule should not be assumed to improve the current-carrying capacity of the conductor or terminal.
The Partex UCEF110 is a practical choice for electrical contractors, panel builders and maintenance engineers requiring consistent, professional conductor preparation across industrial electrical installations.
Tick the specs you need, then view products that match.
| Supply Format | Pack of 1000 | |
|---|---|---|
| Device Type | Uninsulated Ferrule | |
| Conductor Size | 1 mm² | |
| Insulation Type | Non-insulated | |
| Pin Length (mm) | 10 mm | |
| Manufacturer | Partex | |
| Product range | UCEF Uninsulated Cord End Ferrules | |
| Model | UCEF110 | |
| Product type | Uninsulated cord end ferrule | |
| Alternative description | Uninsulated bootlace ferrule | |
| Ferrule configuration | Single conductor | |
| Number of conductors | 1 | |
| Nominal conductor cross-section | 1 mm² | |
| Metal barrel length | 10 mm | |
| Insulation | Uninsulated, without plastic collar | |
| Conductor type | Flexible stranded copper | |
| Termination method | Mechanical crimping | |
| Required tooling | Compatible cord end ferrule crimping tool | |
| Primary function | Flexible conductor end termination | |
| Typical applications | Electrical control panels, terminal blocks, industrial automation and machinery wiring | |
| HS Code | 85369010 |
The Partex UCEF110 is an uninsulated cord end ferrule designed to terminate a flexible stranded copper conductor before connection to a compatible electrical terminal. It helps consolidate individual conductor strands into a compact crimped termination.
The UCEF110 is designed for a single flexible stranded copper conductor with a nominal cross-sectional area of 1 mm².
The UCEF110 features a 10 mm metal barrel length. The barrel length should be compatible with the receiving terminal's insertion depth and conductor preparation requirements.
No. The UCEF110 is an uninsulated cord end ferrule and does not feature a plastic insulating collar. The electrical installation must provide the necessary insulation and protection against accidental contact.
An insulated cord end ferrule includes a plastic collar that helps guide the conductor into the metal barrel, while an uninsulated ferrule consists of the crimpable termination barrel without that collar. Both require suitable crimping equipment and compatibility with the receiving terminal.
Yes. The UCEF110 can be used in electrical control panels, automation equipment and machinery wiring where a 1 mm² uninsulated ferrule is compatible with the terminal and installation requirements.
Use a cord end ferrule crimping tool suitable for uninsulated ferrules and 1 mm² flexible copper conductors. The tool should produce a correctly formed crimp without damaging the ferrule or conductor strands.
The UCEF110 may be used with compatible screw-clamp or spring-clamp terminals where the terminal manufacturer permits uninsulated ferrules of the relevant size and crimped dimensions. Always check the terminal specifications before installation.
No. A cord end ferrule helps prepare and consolidate stranded conductors but does not increase their rated current-carrying capacity. The circuit must remain within the specified ratings of the conductor, terminal and associated electrical equipment.
Partex conductor termination products provide practical solutions for electrical panel builders, automation engineers and industrial maintenance teams. The UCEF110 uninsulated cord end ferrule combines a 1 mm² conductor size, 10 mm crimp barrel and compact collar-free construction to support neat, consistent and professionally prepared electrical connections.
We use cookies