Partex TCEF1014G-K twin insulated cord end ferrule for two compatible 10 mm² flexible stranded conductors, featuring a 14 mm metal barrel and ivory insulating collar, supplied in a bulk pack of 1000 for professional electrical cable termination and panel manufacturing.
£190.36
The Partex TCEF1014G-K twin insulated cord end ferrule is a professional electrical termination accessory designed for joining two compatible 10 mm² flexible stranded conductors within a single crimped termination. Featuring a 14 mm metal barrel and an ivory-coloured insulating collar, this twin-entry bootlace ferrule provides a practical solution for preparing conductors in electrical control panels, switchgear assemblies, industrial machinery and power distribution equipment.
Designed for applications where two conductors must be connected to a single compatible terminal, the Partex TCEF1014G-K helps contain individual wire strands within a metal crimp barrel. The twin-entry insulating collar guides both conductors into the ferrule, supporting neat and consistent conductor preparation. When installed using suitable crimping equipment, the ferrule helps produce an organised termination that can be inserted into a receiving terminal approved for the completed twin-conductor connection.
Supplied in a bulk pack of 1,000 ferrules, the TCEF1014G-K is particularly well suited to electrical panel manufacturers, industrial equipment builders, automation engineers and high-volume wiring operations. Its 2 × 10 mm² conductor configuration, 14 mm barrel length and ivory insulation make it a convenient choice for repetitive electrical termination work where consistent component selection and efficient production are important.
The Partex TCEF1014G-K twin insulated ferrule is designed for electrical assemblies where two flexible stranded conductors need to be terminated together in one compatible connection. Flexible conductors contain multiple individual strands that can spread or become displaced during termination. A correctly crimped ferrule helps contain these strands within a metal barrel, creating a tidy conductor end for insertion into a suitable terminal.
The 2 × 10 mm² twin-conductor configuration allows two compatible conductors, each with a nominal cross-sectional area of 10 mm², to be prepared as one crimped termination. This arrangement can be useful in electrical distribution equipment, control panels and machinery assemblies where the electrical design requires a shared terminal connection. However, the receiving terminal must be approved for the completed twin-ferrule dimensions and conductor arrangement.
The specified 14 mm barrel length is an important consideration when matching the ferrule to a terminal. The barrel must be suitable for the terminal's insertion depth and clamping mechanism, while the crimped ferrule must fit within the terminal's permitted conductor entry dimensions. Installers should confirm these requirements rather than relying solely on the nominal conductor cross-section.
The ivory insulating collar helps position the two conductors during insertion and provides a consistent appearance across completed terminations. While colour coding can help with ferrule selection, conventions may differ between manufacturers and product ranges. The correct ferrule should therefore be selected using the part number, conductor size and manufacturer's specifications rather than colour alone.
A major advantage of the TCEF1014G-K is its 1,000-piece bulk pack. This quantity is particularly useful for control panel production lines, industrial wiring workshops and equipment manufacturers performing repetitive crimping operations. Compared with smaller packs, a bulk supply can simplify consumable planning and reduce interruptions caused by frequent replenishment.
For consistent termination quality, both conductors should be stripped to the correct length, fully inserted into the ferrule and crimped using compatible tooling. The finished crimp should be inspected for complete strand capture, correct formation and secure conductor retention. The ferrule is a conductor termination accessory and does not replace the electrical ratings, protective insulation or connection requirements of the receiving terminal.
Tick the specs you need, then view products that match.
| Colour Code | German colour code (DIN 46228-4) | |
|---|---|---|
| Supply Format | Pack of 1000 | |
| Conductor Size | 10 mm² | |
| Insulation Type | Insulated | |
| Pin Length (mm) | 14 mm | |
| Colour | Ivory | |
| Device Type | Twin Insulated Ferrule | |
| Manufacturer | Partex | |
| Manufacturer part number | TCEF1014G-K | |
| Product type | Twin insulated cord end ferrule | |
| Alternative description | Twin insulated bootlace ferrule | |
| Entry configuration | Twin conductor | |
| Nominal conductor size | 2 × 10 mm² | |
| Nominal size per conductor | 10 mm² | |
| Barrel length | 14 mm | |
| Insulation colour | Ivory | |
| Pack quantity | 1,000 | |
| Termination method | Crimping | |
| Primary application | Termination of two compatible flexible stranded conductors | |
| Ferrule configuration | Insulated twin-entry metal barrel | |
| Recommended tooling | Compatible twin-ferrule crimping tool and die | |
| Terminal compatibility | Receiving terminals approved for the completed twin-ferrule connection | |
| Conductor preparation | Strip to the manufacturer's recommended length | |
| Barrel material and plating | Refer to manufacturer technical data | |
| Overall ferrule dimensions | Refer to manufacturer technical data | |
| Applicable standards and approvals | Refer to manufacturer technical data | |
| Product identification | TCEF1014G-K | |
| HS Code | 85369010 |
The Partex TCEF1014G-K is designed to terminate two compatible 10 mm² flexible stranded conductors together within a single crimped ferrule. It is suitable for electrical panel and equipment wiring where the receiving terminal is approved for the completed twin-ferrule connection.
The TCEF1014G-K has a nominal conductor designation of 2 × 10 mm². This means it is intended for two compatible conductors, each with a nominal cross-sectional area of 10 mm².
The ferrule has a 14 mm metal barrel length. This dimension should be checked against the insertion depth and clamping requirements of the receiving terminal.
The Partex TCEF1014G-K features an ivory-coloured insulating collar. The product designation and conductor size should be used to confirm the correct ferrule, as colour conventions can vary.
Each pack contains 1,000 Partex TCEF1014G-K twin insulated cord end ferrules, making it particularly suitable for bulk electrical assembly, panel manufacturing and repetitive crimp termination work.
Both products are Partex twin insulated cord end ferrules with a 2 × 10 mm² conductor designation, 14 mm barrel and ivory insulating collar. The difference is the supplied quantity: TCEF1014G-K contains 1,000 ferrules, while TCEF1014G-C contains 100 ferrules.
The 1,000-piece pack is convenient for high-volume electrical manufacturing and panel-building operations. It provides a larger supply of identical ferrules, helping reduce the frequency of stock replenishment during repetitive termination work.
Yes. The TCEF1014G-K is intended for compatible flexible stranded conductors. The conductor construction and nominal cross-sectional area should be verified against the manufacturer's specifications before crimping.
A ferrule crimping tool and die compatible with the TCEF1014G-K twin-conductor configuration should be used. Tool selection must account for the combined conductor arrangement and required crimp dimensions. Compatibility should be confirmed with the ferrule and tooling manufacturers.
The TCEF1014G-K is designed to terminate two compatible 10 mm² conductors together. However, the receiving terminal must be approved for the resulting twin-ferrule dimensions and conductor arrangement. Using a twin ferrule does not override the terminal manufacturer's connection requirements.
With the circuit safely isolated, strip both conductors to the recommended length, insert them fully into the twin ferrule and crimp using compatible tooling. Inspect the completed crimp for secure conductor retention and correct formation before inserting it into an approved terminal.
A crimped ferrule should generally be treated as a single-use termination. If the crimp is damaged or incorrectly formed, the connection should be remade using a new ferrule and properly prepared conductors.
Partex twin insulated cord end ferrules provide a practical solution for producing organised, consistent conductor terminations in professional electrical assemblies. With its 2 × 10 mm² conductor designation, 14 mm barrel, ivory insulating collar and bulk pack of 1,000, the TCEF1014G-K is particularly suited to high-volume panel manufacturing and industrial wiring operations where compatible tooling and approved terminal connections are used.