Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Partex TCEF1014G-C twin insulated cord end ferrule for two compatible 10 mm² flexible stranded conductors, featuring a 14 mm metal barrel and ivory insulating collar, supplied in a pack of 100 for professional electrical cable termination.
£21.23
The Partex TCEF1014G-C twin insulated cord end ferrule is a professional electrical termination accessory designed to provide a neat, secure and consistent crimped termination for two compatible 10 mm² flexible conductors entering a shared terminal connection. Featuring a 14 mm metal barrel length and an ivory-coloured insulating collar, this twin-entry bootlace ferrule is ideal for electrical panel building, industrial control equipment and power distribution assemblies where reliable conductor preparation is essential.
Twin insulated cord end ferrules are used to bring two stranded conductors together into a single crimped termination. The metal barrel helps contain the individual wire strands, while the insulating collar provides an organised entry point for the conductors. When installed using a correctly matched crimping tool and die, the Partex TCEF1014G-C helps produce consistent terminations for compatible screw-clamp and other suitable terminal connections.
Supplied in a convenient pack of 100 ferrules, the TCEF1014G-C is a practical choice for electrical contractors, control panel manufacturers, automation engineers and industrial maintenance teams. Its 10 mm² twin-conductor designation, 14 mm barrel and distinctive ivory insulation make it easy to identify the required ferrule during electrical assembly and maintenance work.
The Partex TCEF1014G-C 10 mm² twin insulated ferrule is designed for electrical assemblies where two flexible stranded conductors need to be terminated together in a single compatible connection. Without appropriate conductor preparation, fine strands can separate or become displaced during insertion into a terminal. A correctly crimped cord end ferrule contains the strands within a metal barrel, helping create a neat, repeatable termination.
The twin-entry construction is particularly useful for wiring arrangements that require two conductors to share one termination point. Both conductors enter the insulating collar and are crimped together within the ferrule barrel. This can be useful in electrical control panels and distribution assemblies, but the receiving terminal must be specifically suitable for the completed twin-ferrule arrangement. A twin ferrule does not automatically make an otherwise unsuitable terminal acceptable for two conductors.
The specified 14 mm barrel length is an important consideration when selecting the ferrule for a particular terminal. The barrel must be compatible with the terminal's conductor insertion depth and clamping arrangement. Installers should also verify that the terminal can accommodate the external dimensions of the crimped ferrule, rather than selecting the connection solely by the nominal conductor cross-section.
The ivory insulating collar helps guide the two conductors into the ferrule and provides a consistent appearance during electrical assembly. Colour coding can assist with component selection, but ferrule colour conventions may vary between product ranges and coding systems. The printed product designation and confirmed conductor size should therefore be used to verify the correct ferrule rather than relying on colour alone.
Correct crimping is essential for a reliable connection. Both conductors should be prepared to the manufacturer's recommended stripping length, inserted fully into the ferrule and crimped using tooling suitable for the combined conductor arrangement. The finished crimp should be checked for secure conductor retention, complete strand capture and correct dimensions before insertion into the receiving terminal.
Supplied in a pack of 100, the Partex TCEF1014G-C is suitable for panel-building workshops, industrial maintenance departments and electrical equipment manufacturers requiring consistent twin-conductor terminations. The ferrule is a conductor termination accessory and should not be treated as a substitute for the terminal's electrical ratings, protective insulation or approved connection method.
Tick the specs you need, then view products that match.
| Colour Code | German colour code (DIN 46228-4) | |
|---|---|---|
| Supply Format | Pack of 100 | |
| Conductor Size | 10 mm² | |
| Insulation Type | Insulated | |
| Pin Length (mm) | 14 mm | |
| Colour | Ivory | |
| Device Type | Twin Insulated Ferrule | |
| Manufacturer | Partex | |
| Manufacturer part number | TCEF1014G-C | |
| Product type | Twin insulated cord end ferrule | |
| Alternative description | Twin insulated bootlace ferrule | |
| Entry configuration | Twin conductor | |
| Nominal conductor size | 2 × 10 mm² | |
| Nominal size per conductor | 10 mm² | |
| Barrel length | 14 mm | |
| Insulation colour | Ivory | |
| Pack quantity | 100 | |
| Termination method | Crimping | |
| Primary application | Termination of two compatible flexible stranded conductors | |
| Ferrule format | Insulated twin-entry metal barrel | |
| Recommended tooling | Compatible ferrule crimping tool and die | |
| Terminal compatibility | Terminals approved for the completed twin-ferrule connection | |
| Conductor preparation | Strip to the appropriate length for the ferrule and terminal arrangement | |
| Barrel material and plating | Refer to manufacturer technical data | |
| Overall ferrule dimensions | Refer to manufacturer technical data | |
| Applicable standards and approvals | Refer to manufacturer technical data | |
| Product identification | TCEF1014G-C | |
| HS Code | 85369010 |
The Partex TCEF1014G-C is designed to terminate two compatible 10 mm² flexible stranded conductors together in a single crimped ferrule. It is used in electrical equipment and panel wiring where the receiving terminal is approved for the completed twin-ferrule connection.
The TCEF1014G-C has a nominal twin-conductor designation of 2 × 10 mm², meaning it is intended for two compatible conductors, each with a nominal cross-sectional area of 10 mm².
The ferrule has a 14 mm metal barrel length. This dimension should be checked against the insertion depth and connection requirements of the receiving terminal.
The Partex TCEF1014G-C features an ivory-coloured insulating collar. The product part number and conductor size should be used to confirm correct selection, as colour coding conventions can vary.
Each pack contains 100 Partex TCEF1014G-C twin insulated cord end ferrules, providing a convenient quantity for electrical installation, manufacturing and maintenance applications.
A single cord end ferrule is intended to terminate one compatible conductor. A twin cord end ferrule, such as the TCEF1014G-C, is designed to accommodate two compatible conductors within one crimped barrel for use in an appropriately rated terminal connection.
Yes. The TCEF1014G-C is designed for terminating compatible flexible stranded conductors. The conductor construction and cross-sectional area should be checked against the manufacturer's specifications before crimping.
A ferrule crimping tool and die suitable for the TCEF1014G-C twin-conductor size should be used. Tool selection must account for the twin-entry configuration and the completed crimp dimensions. Compatibility should be confirmed with the tool and ferrule manufacturers.
The ferrule is intended to terminate two compatible 10 mm² conductors together. However, the receiving terminal must be approved to accept the resulting twin-ferrule termination, including its dimensions and conductor arrangement. The ferrule does not override the terminal manufacturer's connection limits.
With the circuit safely isolated, prepare both conductors to the recommended stripping length, insert them fully into the twin ferrule and crimp using compatible tooling. Inspect the finished termination for secure conductor retention and correct crimp formation before inserting it into an approved terminal.
Yes. The Partex TCEF1014G-C is suitable for electrical control panel and equipment wiring where 2 × 10 mm² twin-conductor ferrules are specified and the receiving terminals and installation conditions are compatible.
A crimped ferrule should generally be treated as a single-use termination. If a conductor must be removed or the crimp is damaged or incorrectly formed, the termination should be remade using a new ferrule and properly prepared conductors.
Partex twin insulated cord end ferrules provide a practical solution for producing organised, consistent terminations in professional electrical assemblies. With its 2 × 10 mm² conductor designation, 14 mm barrel, ivory insulating collar and convenient pack of 100, the TCEF1014G-C supports efficient conductor preparation and professional wiring practices when installed using compatible crimping equipment and approved terminal connections.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.