The WAGO 2006-1611/1000-836 is a 2-conductor fuse terminal block with integrated LED blown-fuse indication, designed for protected electrical circuits in industrial control panels, automation cabinets and electrical distribution assemblies. Part of the established WAGO TOPJOB S 2006 series, this DIN rail-mounted terminal block combines reliable conductor termination with a convenient pivoting fuse holder for standard miniature cartridge fuses.
Designed for 5 × 20 mm cylindrical fuses, the WAGO 2006-1611/1000-836 features a pivoting fuse carrier that provides convenient access for fuse inspection and replacement after the circuit has been safely isolated. Its integrated 230 V LED blown-fuse indicator helps maintenance personnel identify an open fuse more quickly, reducing diagnostic time during electrical troubleshooting.
The terminal block incorporates Push-in CAGE CLAMP® connection technology, a 6 mm² nominal conductor cross-section and a compact 7.5 mm terminal width. With a manufacturer-specified 10 A IEC rated current, it provides a practical solution for fused control and distribution circuits where dependable electrical connections, clear fault indication and efficient DIN rail installation are required.
Fuse terminal blocks such as the WAGO 2006-1611/1000-836 provide a compact method of incorporating cartridge fuse protection into DIN rail terminal assemblies. Instead of installing a separate fuse holder and additional connection terminals, the fuse terminal block combines conductor termination and a replaceable fuse carrier within a single rail-mounted component.
The integrated 230 V LED blown-fuse indicator provides a useful diagnostic feature in electrical control panels. When a fuse opens under suitable circuit conditions, the LED indication helps identify the affected fuse position, allowing maintenance personnel to locate the circuit requiring attention. The indicator circuit can permit approximately 2 mA leakage current when the fuse is blown, so the suitability of this function must be assessed for connected equipment, particularly sensitive electronic loads.
The pivoting fuse carrier is designed for standard 5 × 20 mm miniature fuses and provides convenient access during planned maintenance. Fuse replacement must be carried out only after the circuit has been safely isolated and verified de-energised. The replacement fuse must have the correct current rating, voltage rating, breaking capacity and operating characteristic for the protected circuit.
The terminal block's Push-in CAGE CLAMP® connections provide dependable conductor retention using spring-pressure technology. Suitable solid conductors and ferruled fine-stranded conductors can be inserted directly, while the operating slots allow tool-assisted connection and release. This supports efficient panel wiring and maintenance without routine screw retightening.
Although the terminal block has an 800 V IEC insulation rating, the integrated blown-fuse indicator is specified for 230 V operation. The insulation rating must not be interpreted as permission to operate the LED-equipped fuse circuit at 800 V. Circuit voltage, current and protection requirements must be evaluated against the complete fuse terminal block configuration.
Tick the specs you need, then view products that match.
| Current | 10 A | |
|---|---|---|
| Voltage | 800 V | |
| Terminal Type | Fuse | |
| Colour | Grey | |
| Connection | Spring clamp | |
| Number of Levels | 1 | |
| Product Series | WAGO TOPJOB S | |
| Type of fuse holder | Swivelling | |
| Type of fuse insert | G-fuse 5x20 mm | |
| Connectable conductor cross section fine-strand with cable end sleeve | 1.5 – 6 mm² | |
| Height | 96.3 mm | |
| Operating temperature | 105 – 105 °C | |
| Flammability class of insulation material according to UL 94 | V0 | |
| Rated current In | 10 A | |
| Connectable conductor cross section fine-strand without cable end sleeve | 0.5 – 10 mm² | |
| Width | 7.5 mm | |
| Rated voltage | 800 V | |
| Material insulation body | Thermoplastic | |
| Type of electrical connection 2 | Spring clamp connection | |
| Number of levels | 1 | |
| Type of electrical connection 1 | Spring clamp connection | |
| Colour | Grey | |
| Closing plate required | Yes | |
| Connectable conductor cross section multi-wired | 0.5 – 6 mm² | |
| Connectable conductor cross section solid-core | 1 – 10 mm² | |
| Depth | 59 mm | |
| Supply voltage for defect-indication | 230 – 230 V | |
| Voltage type for defect indication | AC | |
| Mounting method | DIN rail (top hat rail) 35 mm | |
| Type of indication element for defect indication | LED | |
| Manufacturer | WAGO | |
| Product range | TOPJOB S | |
| Series | 2006 | |
| Manufacturer part number | 2006-1611/1000-836 | |
| Product type | Fuse terminal block with LED blown-fuse indication | |
| Terminal configuration | 2-conductor | |
| Number of connection points | 2 | |
| Number of potentials | 1 | |
| Number of jumper slots | 2 | |
| Fuse holder type | Pivoting fuse carrier | |
| Compatible fuse size | 5 × 20 mm | |
| Fuse type | Cylindrical miniature cartridge fuse | |
| Blown-fuse indication | Integrated LED | |
| Indicator operating voltage | 230 V | |
| Rated current (IEC/EN) | 10 A | |
| Rated voltage (IEC/EN) | 800 V | |
| Rated impulse withstand voltage | 8 kV | |
| Overvoltage category | III | |
| Pollution degree | 3 | |
| Applicable standard | IEC/EN 60947-7-3 | |
| Rated current (UL) | 15 A | |
| Rated voltage (UL) | 230 V | |
| Nominal conductor cross-section | 6 mm² | |
| Connection technology | Push-in CAGE CLAMP® | |
| Actuation method | Push-in / operating tool | |
| Conductor material | Copper | |
| Solid conductor cross-section | 0.5–10 mm² | |
| Solid conductor direct push-in range | 2.5–10 mm² | |
| Fine-stranded conductor cross-section | 0.5–10 mm² | |
| Fine-stranded conductor with insulated ferrule | 0.5–6 mm² | |
| Fine-stranded conductor with ferrule, direct push-in | 2.5–6 mm² | |
| Conductor stripping length | 13–15 mm | |
| Wiring direction | Front entry | |
| Mounting type | DIN-35 rail | |
| Terminal width | 7.5 mm | |
| Depth from upper edge of DIN rail | 59 mm | |
| Dimensions (W × H × D) | 7.5 × 96.3 × 59 mm | |
| Housing material | Polyamide 66 (PA66) | |
| Material group | I | |
| Flammability classification | UL94 V-0 | |
| Marking positions | Centre / side | |
| Processing temperature | −35 to +85 °C | |
| Continuous operating temperature | −60 to +105 °C | |
| Weight | Approx. 25.4 g | |
| Packaging unit | 25 pieces | |
| Country of origin | Germany | |
| GTIN / EAN | 4045454824020 | |
| Important electrical note | Applicable circuit ratings depend on the installed fuse and blown-fuse indicator configuration. | |
| Blown-fuse leakage current | Approximately 2 mA through the LED indicator circuit when the fuse is open. |
The WAGO 2006-1611/1000-836 is a two-conductor fuse terminal block designed for electrical circuits requiring cartridge fuse protection and visual blown-fuse indication. It combines a pivoting fuse holder, Push-in CAGE CLAMP® conductor connections and a 230 V LED indicator within a DIN rail-mounted assembly.
The terminal block accepts standard 5 × 20 mm miniature cylindrical cartridge fuses. The installed fuse must be selected according to the circuit's operating voltage, current, fault level and required protection characteristics.
The integrated 230 V LED provides visual blown-fuse indication when the circuit conditions are suitable. When the fuse opens, the indicator can help maintenance personnel identify the affected circuit. The LED circuit may allow approximately 2 mA leakage current when the fuse is blown.
The terminal block has a manufacturer-specified 10 A IEC rated current and a nominal conductor cross-section of 6 mm². It accepts suitable solid and fine-stranded copper conductors from 0.5–10 mm². The actual permissible circuit current also depends on the installed fuse and complete assembly ratings.
The terminal block has an 800 V IEC insulation rating, but this specific variant incorporates a 230 V blown-fuse LED indicator. The insulation rating does not mean that the complete LED-equipped fuse circuit is suitable for operation at 800 V. The installed fuse, indicator and application voltage must all be compatible with the intended circuit.
WAGO TOPJOB S terminal block systems are widely used by electrical engineers, panel builders and industrial automation specialists for reliable and space-efficient wiring. The WAGO 2006-1611/1000-836 combines spring-pressure conductor termination, a pivoting cartridge fuse holder and 230 V LED blown-fuse indication to support organised electrical protection and efficient maintenance in industrial control systems.