Why Choose the WAGO 2006-1611/1000-836 TOPJOB S Fuse Terminal Block?

The WAGO 2006-1611/1000-836 is a 2-conductor fuse terminal block with integrated LED blown-fuse indication, designed for protected electrical circuits in industrial control panels, automation cabinets and electrical distribution assemblies. Part of the established WAGO TOPJOB S 2006 series, this DIN rail-mounted terminal block combines reliable conductor termination with a convenient pivoting fuse holder for standard miniature cartridge fuses.

Designed for 5 × 20 mm cylindrical fuses, the WAGO 2006-1611/1000-836 features a pivoting fuse carrier that provides convenient access for fuse inspection and replacement after the circuit has been safely isolated. Its integrated 230 V LED blown-fuse indicator helps maintenance personnel identify an open fuse more quickly, reducing diagnostic time during electrical troubleshooting.

The terminal block incorporates Push-in CAGE CLAMP® connection technology, a 6 mm² nominal conductor cross-section and a compact 7.5 mm terminal width. With a manufacturer-specified 10 A IEC rated current, it provides a practical solution for fused control and distribution circuits where dependable electrical connections, clear fault indication and efficient DIN rail installation are required.

Key Advantages

  • Integrated fuse protection: Accommodates standard 5 × 20 mm miniature cartridge fuses for protecting compatible electrical circuits.
  • 230 V LED blown-fuse indication: Provides visual identification of a blown fuse under suitable operating conditions.
  • Pivoting fuse holder: Allows convenient access to the fuse during inspection and maintenance.
  • Push-in CAGE CLAMP® technology: Provides secure, spring-pressure conductor connections without conventional screw tightening.
  • Compact 7.5 mm width: Supports space-efficient installation in industrial control cabinets.
  • 6 mm² nominal cross-section: Supports a range of copper conductor sizes for electrical panel wiring.
  • Two conductor connection points: Provides an organised incoming and outgoing circuit connection arrangement.
  • DIN rail mounting: Fits standard 35 mm mounting rails for straightforward panel assembly.
  • Flame-retardant PA66 housing: Provides durable electrical insulation and mechanical protection.
  • TOPJOB S compatibility: Integrates into compatible WAGO terminal block assemblies and marking systems.

Key Features

  • WAGO TOPJOB S 2006 series fuse terminal block.
  • 2-conductor, single-level configuration.
  • Pivoting fuse holder for 5 × 20 mm miniature metric fuses.
  • Integrated 230 V LED blown-fuse indicator.
  • 10 A rated current according to IEC/EN 60947-7-3.
  • 800 V IEC rated insulation voltage, subject to the electrical ratings and limitations of the fuse and indicator circuit.
  • 8 kV rated impulse withstand voltage.
  • 6 mm² nominal conductor cross-section.
  • Push-in CAGE CLAMP® spring-pressure connection technology.
  • Accepts suitable solid and fine-stranded copper conductors from 0.5–10 mm².
  • Front-entry conductor wiring for accessible panel connections.
  • 13–15 mm conductor stripping length.
  • 7.5 mm terminal width for compact DIN rail installations.
  • DIN-35 rail mounting, compatible with 35 × 7.5 mm and 35 × 15 mm rails.
  • Grey polyamide 66 insulating housing with UL94 V-0 flammability classification.
  • Centre and side marking positions for circuit identification.

Reliable Fuse Protection and Fault Indication for Industrial Control Circuits

Fuse terminal blocks such as the WAGO 2006-1611/1000-836 provide a compact method of incorporating cartridge fuse protection into DIN rail terminal assemblies. Instead of installing a separate fuse holder and additional connection terminals, the fuse terminal block combines conductor termination and a replaceable fuse carrier within a single rail-mounted component.

The integrated 230 V LED blown-fuse indicator provides a useful diagnostic feature in electrical control panels. When a fuse opens under suitable circuit conditions, the LED indication helps identify the affected fuse position, allowing maintenance personnel to locate the circuit requiring attention. The indicator circuit can permit approximately 2 mA leakage current when the fuse is blown, so the suitability of this function must be assessed for connected equipment, particularly sensitive electronic loads.

The pivoting fuse carrier is designed for standard 5 × 20 mm miniature fuses and provides convenient access during planned maintenance. Fuse replacement must be carried out only after the circuit has been safely isolated and verified de-energised. The replacement fuse must have the correct current rating, voltage rating, breaking capacity and operating characteristic for the protected circuit.

The terminal block's Push-in CAGE CLAMP® connections provide dependable conductor retention using spring-pressure technology. Suitable solid conductors and ferruled fine-stranded conductors can be inserted directly, while the operating slots allow tool-assisted connection and release. This supports efficient panel wiring and maintenance without routine screw retightening.

Although the terminal block has an 800 V IEC insulation rating, the integrated blown-fuse indicator is specified for 230 V operation. The insulation rating must not be interpreted as permission to operate the LED-equipped fuse circuit at 800 V. Circuit voltage, current and protection requirements must be evaluated against the complete fuse terminal block configuration.

Typical Applications

  • Industrial electrical control panels and automation cabinets.
  • 230 V control circuits requiring individual fuse protection and fault indication.
  • WAGO TOPJOB S DIN rail terminal block assemblies.
  • PLC control cabinets and associated electrical equipment.
  • Machinery control panels and OEM electrical systems.
  • Industrial electrical distribution and auxiliary circuits.
  • Building automation and electrical control installations.
  • Electrical maintenance systems requiring visual blown-fuse identification.
  • Compact DIN rail-mounted fuse distribution arrangements.
  • Electrical panel construction, refurbishment and maintenance.

Technical Specifications

Tick the specs you need, then view products that match.

Current 10 A
Voltage 800 V
Terminal Type Fuse
Colour Grey
Connection Spring clamp
Number of Levels 1
Product Series WAGO TOPJOB S
Type of fuse holder Swivelling
Type of fuse insert G-fuse 5x20 mm
Connectable conductor cross section fine-strand with cable end sleeve 1.5 – 6 mm²
Height 96.3 mm
Operating temperature 105 – 105 °C
Flammability class of insulation material according to UL 94 V0
Rated current In 10 A
Connectable conductor cross section fine-strand without cable end sleeve 0.5 – 10 mm²
Width 7.5 mm
Rated voltage 800 V
Material insulation body Thermoplastic
Type of electrical connection 2 Spring clamp connection
Number of levels 1
Type of electrical connection 1 Spring clamp connection
Colour Grey
Closing plate required Yes
Connectable conductor cross section multi-wired 0.5 – 6 mm²
Connectable conductor cross section solid-core 1 – 10 mm²
Depth 59 mm
Supply voltage for defect-indication 230 – 230 V
Voltage type for defect indication AC
Mounting method DIN rail (top hat rail) 35 mm
Type of indication element for defect indication LED
Manufacturer WAGO
Product range TOPJOB S
Series 2006
Manufacturer part number 2006-1611/1000-836
Product type Fuse terminal block with LED blown-fuse indication
Terminal configuration 2-conductor
Number of connection points 2
Number of potentials 1
Number of jumper slots 2
Fuse holder type Pivoting fuse carrier
Compatible fuse size 5 × 20 mm
Fuse type Cylindrical miniature cartridge fuse
Blown-fuse indication Integrated LED
Indicator operating voltage 230 V
Rated current (IEC/EN) 10 A
Rated voltage (IEC/EN) 800 V
Rated impulse withstand voltage 8 kV
Overvoltage category III
Pollution degree 3
Applicable standard IEC/EN 60947-7-3
Rated current (UL) 15 A
Rated voltage (UL) 230 V
Nominal conductor cross-section 6 mm²
Connection technology Push-in CAGE CLAMP®
Actuation method Push-in / operating tool
Conductor material Copper
Solid conductor cross-section 0.5–10 mm²
Solid conductor direct push-in range 2.5–10 mm²
Fine-stranded conductor cross-section 0.5–10 mm²
Fine-stranded conductor with insulated ferrule 0.5–6 mm²
Fine-stranded conductor with ferrule, direct push-in 2.5–6 mm²
Conductor stripping length 13–15 mm
Wiring direction Front entry
Mounting type DIN-35 rail
Terminal width 7.5 mm
Depth from upper edge of DIN rail 59 mm
Dimensions (W × H × D) 7.5 × 96.3 × 59 mm
Housing material Polyamide 66 (PA66)
Material group I
Flammability classification UL94 V-0
Marking positions Centre / side
Processing temperature −35 to +85 °C
Continuous operating temperature −60 to +105 °C
Weight Approx. 25.4 g
Packaging unit 25 pieces
Country of origin Germany
GTIN / EAN 4045454824020
Important electrical note Applicable circuit ratings depend on the installed fuse and blown-fuse indicator configuration.
Blown-fuse leakage current Approximately 2 mA through the LED indicator circuit when the fuse is open.

Frequently Asked Questions

What is the WAGO 2006-1611/1000-836 used for?

The WAGO 2006-1611/1000-836 is a two-conductor fuse terminal block designed for electrical circuits requiring cartridge fuse protection and visual blown-fuse indication. It combines a pivoting fuse holder, Push-in CAGE CLAMP® conductor connections and a 230 V LED indicator within a DIN rail-mounted assembly.

What fuse size does the WAGO 2006-1611/1000-836 accept?

The terminal block accepts standard 5 × 20 mm miniature cylindrical cartridge fuses. The installed fuse must be selected according to the circuit's operating voltage, current, fault level and required protection characteristics.

What is the purpose of the 230 V LED indicator?

The integrated 230 V LED provides visual blown-fuse indication when the circuit conditions are suitable. When the fuse opens, the indicator can help maintenance personnel identify the affected circuit. The LED circuit may allow approximately 2 mA leakage current when the fuse is blown.

What are the current rating and conductor capacity of the WAGO 2006-1611/1000-836?

The terminal block has a manufacturer-specified 10 A IEC rated current and a nominal conductor cross-section of 6 mm². It accepts suitable solid and fine-stranded copper conductors from 0.5–10 mm². The actual permissible circuit current also depends on the installed fuse and complete assembly ratings.

Can the WAGO 2006-1611/1000-836 be used on an 800 V circuit?

The terminal block has an 800 V IEC insulation rating, but this specific variant incorporates a 230 V blown-fuse LED indicator. The insulation rating does not mean that the complete LED-equipped fuse circuit is suitable for operation at 800 V. The installed fuse, indicator and application voltage must all be compatible with the intended circuit.

Trusted by Industrial Electrical and Automation Professionals Worldwide

WAGO TOPJOB S terminal block systems are widely used by electrical engineers, panel builders and industrial automation specialists for reliable and space-efficient wiring. The WAGO 2006-1611/1000-836 combines spring-pressure conductor termination, a pivoting cartridge fuse holder and 230 V LED blown-fuse indication to support organised electrical protection and efficient maintenance in industrial control systems.