2002-2671 Wago Double-Deck Disconnect Tb, With Pivoting Knife Disconnect Gray Housing Gray

2002-2671 Wago Double-Deck Disconnect Tb, With Pivoting Knife Disconnect Gray Housing Gray

SKU: 2002-2671MPN: 2002-2671
Price
List Price £4.06 ex VAT
Your Price (ex VAT) Save 35%
£2.64 35% OFF
You save £1.42 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2.64
Trade pricing is personalised to your account

Manufacturer Lead Time

Sold in packs of 50

£2.64

Why Choose the WAGO 2002-2671 TOPJOB® S Double-Deck Disconnect Terminal Block?

The WAGO 2002-2671 is a compact double-deck disconnect terminal block with a pivoting knife disconnect, designed for industrial electrical control panels, automation cabinets and machinery installations. Part of the WAGO TOPJOB® S 2002 series, this grey terminal block combines a continuous lower-level feed-through connection with an upper-level disconnect function, allowing two circuit functions to be accommodated within a single DIN rail terminal position.

Featuring an L/L configuration, the WAGO 2002-2671 provides four conductor connection points across two levels. The lower level maintains a continuous electrical connection, while the upper level incorporates a manually operated pivoting knife disconnect. This enables the upper circuit to be opened for testing, commissioning or maintenance without interrupting the lower feed-through connection.

The terminal block uses Push-in CAGE CLAMP® spring pressure connection technology for dependable conductor termination. With a 2.5 mm² nominal conductor cross-section, 400 V IEC rated voltage, 16 A rated current and a compact 5.2 mm width, the WAGO 2002-2671 provides a practical solution for space-efficient electrical circuit distribution and functional disconnection.

Key Advantages

  • Integrated pivoting knife disconnect: Allows the upper-level circuit to be opened for testing, commissioning and maintenance.
  • Continuous lower-level feed-through: Maintains a separate uninterrupted conductor connection.
  • Double-deck design: Combines feed-through and disconnect functions within one compact terminal housing.
  • L/L configuration: Supports organised line conductor connections across two levels.
  • Four conductor connection points: Provides two connection points on each level.
  • Push-in CAGE CLAMP® technology: Enables fast, reliable conductor termination without conventional screw-terminal tightening.
  • 400 V IEC rated voltage: Suitable for appropriately rated industrial electrical control circuits.
  • 16 A rated current: Supports common industrial control and auxiliary circuit applications.
  • 2.5 mm² nominal conductor cross-section: Accommodates widely used industrial wiring sizes.
  • Compact 5.2 mm width: Helps maximise available DIN rail space.
  • Clear disconnect operation: Provides an accessible mechanical separation point within the upper-level circuit.
  • Modular TOPJOB® S construction: Integrates with compatible WAGO terminal marking and assembly accessories.

Key Features

  • WAGO TOPJOB® S 2002 series terminal block.
  • Double-deck feed-through and disconnect configuration.
  • Pivoting knife disconnect on the upper level.
  • Continuous feed-through connection on the lower level.
  • L/L conductor configuration.
  • Two terminal levels.
  • Four conductor connection points.
  • Three electrical potentials when the disconnect is open.
  • Push-in CAGE CLAMP® spring pressure connection technology.
  • Nominal conductor cross-section of 2.5 mm².
  • Conductor connection range of 0.25–4 mm², depending on conductor type.
  • IEC rated voltage of 400 V.
  • IEC rated current of 16 A.
  • Rated impulse withstand voltage of 6 kV.
  • Conductor stripping length of 10–12 mm.
  • Compact terminal width of 5.2 mm.
  • Grey insulating housing.
  • Compatible with standard 35 mm DIN rails.
  • Suitable for specified Ex applications subject to certification and installation requirements.

Reliable Circuit Disconnection and Continuous Feed-Through Wiring

The WAGO 2002-2671 is designed for applications requiring a combination of uninterrupted electrical connection and convenient circuit disconnection. Its double-deck construction provides two distinct functions within one compact terminal block, helping reduce the number of separate terminal positions needed in industrial control cabinets.

The lower level operates as a conventional feed-through terminal, providing a continuous electrical connection between its conductor termination points. The upper level incorporates a pivoting knife disconnect, allowing the connection between its two terminals to be opened when required. This makes the terminal particularly useful for circuit testing, commissioning and fault investigation.

When the pivoting knife disconnect is closed, the upper-level conductor terminals are electrically connected. When the disconnect is opened, the upper-level connection is interrupted, creating separate potentials on either side of the disconnect. The lower-level feed-through circuit remains unaffected by the upper-level disconnect operation.

The terminal block's Push-in CAGE CLAMP® connection system provides reliable conductor clamping through spring pressure technology. Suitable solid conductors and appropriately ferruled fine-stranded conductors can be inserted directly within the specified conductor ranges, helping improve installation speed and consistency during control panel manufacture.

With a 400 V IEC rated voltage, 16 A rated current and 6 kV impulse withstand voltage, the WAGO 2002-2671 is suitable for a wide range of industrial control and auxiliary electrical circuits. Its narrow 5.2 mm width supports high-density DIN rail layouts without sacrificing access to the disconnect function.

The pivoting knife disconnect is intended for functional circuit separation and testing in accordance with the manufacturer's instructions. It must not be treated as a substitute for a suitably rated main isolator, protective switching device or approved lockable isolation arrangement where these are required.

Typical Applications

  • Industrial electrical control panels and automation cabinets.
  • Control circuit testing and commissioning.
  • PLC input and output wiring arrangements.
  • Machine building and OEM electrical panel manufacturing.
  • Industrial machinery auxiliary circuits.
  • Electrical circuits requiring a dedicated test or disconnect point.
  • Process control and instrumentation cabinets.
  • Building automation and electrical control systems.
  • Compact DIN rail assemblies requiring separate feed-through and disconnect functions.
  • Appropriately designed Ex ec installations, subject to certification requirements.

Technical Specifications

Tick the specs you need, then view products that match.

Current 16 A
Voltage 400 V
Terminal Type Disconnect / Test
Colour Grey
Connection Spring clamp
Number of Connection Points 4
Number of Levels 2
Product Series WAGO TOPJOB S
Connectable conductor cross section fine-strand with cable end sleeve 0.75 – 2.5 mm²
Number of clamp positions per level 2
Height 93 mm
Operating temperature 105 – 105 °C
Flammability class of insulation material according to UL 94 V0
Rated current In 16 A
Connectable conductor cross section fine-strand without cable end sleeve 0.25 – 4 mm²
Rated voltage 400 V
Width 5.2 mm
Number of levels 2
Material insulation body Thermoplastic
Type of electrical connection 2 Spring clamp connection
Type of electrical connection 1 Spring clamp connection
Closing plate required Yes
Colour Grey
Connectable conductor cross section multi-wired 0.25 – 2.5 mm²
Connectable conductor cross section solid-core 0.75 – 4 mm²
Type of cross disconnection None
Depth 51.7 mm
Type of slitting None
Mounting method DIN rail (top hat rail) 35 mm
Manufacturer WAGO
Product series TOPJOB® S 2002
Manufacturer part number 2002-2671
Product type Double-deck disconnect terminal block
Terminal configuration Through/disconnect
Potential designation L/L
Disconnect mechanism Pivoting knife disconnect
Upper level Disconnect terminal
Lower level Continuous feed-through terminal
Number of conductor connection points 4
Connection points per level 2
Number of electrical potentials 3
Internal connection between levels No
Connection technology Push-in CAGE CLAMP®
Connection method Spring pressure connection
Nominal conductor cross-section 2.5 mm²
Solid conductor range 0.25–4 mm²
Fine-stranded conductor range 0.25–4 mm²
Direct push-in solid conductor range 1–4 mm²
Direct push-in conductor with insulated ferrule 1–2.5 mm²
Conductor size range 22–12 AWG
Conductor material Copper
Rated voltage (IEC) 400 V
Rated current (IEC) 16 A
Rated impulse withstand voltage 6 kV
Overvoltage category III
Pollution degree 3
Rated voltage (UL, Use Group B) 300 V
Rated current (UL, Use Group B) 15 A
Rated voltage (UL, Use Group C) 300 V
Rated current (UL, Use Group C) 15 A
Rated voltage (CSA, Use Groups B/C) 600 V
Rated current (CSA, Use Groups B/C) 15 A
Hazardous-area certification references KIWA 17 ATEX 0030 U / IECEx KIWA 17.0014U
Hazardous-area designation Ex ec IIC Gc
Ex rated voltage 440 V
Ex rated current 14 A
Conductor stripping length 10–12 mm
Compatible DIN rails 35 × 7.5 mm / 35 × 15 mm
Terminal width 5.2 mm
Terminal height 56.4 mm
Terminal depth 93 mm
Housing colour Grey
Insulation material Thermoplastic insulating material
Flammability classification UL 94 V-0
Compatible marking systems WMB, WMB Inline and marking strips
Compatible end and intermediate plate WAGO 2002-2691, grey
Packaging unit 50 pieces

Frequently Asked Questions

What is the WAGO 2002-2671 used for?

The WAGO 2002-2671 is a double-deck disconnect terminal block used in industrial control panels and automation systems where a continuous lower-level feed-through connection and a separately disconnectable upper-level circuit are required.

How does the pivoting knife disconnect work?

The pivoting knife disconnect is fitted to the upper level. In the closed position, it connects the two upper-level conductor terminals. When opened, it interrupts the electrical connection between those terminals while leaving the lower-level feed-through circuit unaffected.

What does the L/L configuration mean?

The L/L configuration indicates that both levels are intended for line conductor applications. The lower level provides a continuous feed-through connection, while the upper level includes the pivoting knife disconnect.

How many conductor connection points does the WAGO 2002-2671 have?

The terminal block provides four conductor connection points, with two connection points on the upper level and two on the lower level.

What is the rated voltage and current of the WAGO 2002-2671?

The WAGO 2002-2671 has a 400 V IEC rated voltage, 16 A IEC rated current and 6 kV rated impulse withstand voltage.

What conductor sizes can the WAGO 2002-2671 accommodate?

The terminal block has a 2.5 mm² nominal conductor cross-section and accepts suitable copper conductors within a 0.25–4 mm² range, depending on conductor construction and termination method.

Does opening the disconnect interrupt both levels?

No. The pivoting knife disconnect operates on the upper level only. The lower-level feed-through connection remains electrically continuous when the upper disconnect is opened.

What is the difference between WAGO 2002-2671 and 2002-2672?

Both products are TOPJOB® S double-deck terminal blocks with a pivoting knife disconnect. The 2002-2671 has an L/L configuration, whereas the 2002-2672 has an N/L configuration.

Is the WAGO 2002-2671 suitable for hazardous-area applications?

The WAGO 2002-2671 has documented Ex ec IIC Gc certification references for specified applications. Installation in hazardous areas must follow the applicable certification conditions, electrical ratings and relevant installation standards.

Which DIN rails are compatible with the WAGO 2002-2671?

The terminal block is designed for standard 35 × 7.5 mm and 35 × 15 mm DIN rails used in industrial electrical control cabinets.

Can the WAGO 2002-2671 replace a main electrical isolator?

No. The pivoting knife disconnect provides a functional circuit separation point for suitable testing and maintenance applications. It is not a substitute for a properly rated main isolator or protective switching device where one is required.

Trusted by Industrial Automation and Electrical Engineering Professionals

WAGO TOPJOB® S terminal blocks are widely used in industrial electrical installations where secure conductor connections, efficient panel construction and accessible circuit testing are important. The WAGO 2002-2671 combines a continuous lower-level feed-through connection, an upper-level pivoting knife disconnect and Push-in CAGE CLAMP® technology to provide dependable circuit organisation and convenient functional disconnection in compact DIN rail assemblies.