1sna116861r1300 - m30pwa

1sna116861r1300 – m30pwa

TE Connectivity 1SNA116861R1300 M30-D-PWA is an ENTRELEC ESSAILEC test and disconnect block designed for safe current and voltage measurement, monitoring, testing and maintenance of electrical measurement and protection circuits.

SKU: 1SNA116861R1300Alt SKU: M30PWAMPN: 1SNA116861R1300
Price
List Price £128.06 ex VAT
Your Price (ex VAT) Save 35%
£83.24 35% OFF
You save £44.82 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £83.24
Trade pricing is personalised to your account

Manufacturer Lead Time

Sold in packs of 10

£83.24

Why Choose the TE Connectivity M30-D-PWA 1SNA116861R1300 ESSAILEC Test Block?

The TE Connectivity M30-D-PWA 1SNA116861R1300, also identified as M30PWA, is an industrial ESSAILEC test and disconnect block designed for safe testing and measurement operations in secondary current and voltage circuits. The ESSAILEC system provides a dedicated interface between measurement or protection equipment and associated current transformers, voltage transformers and sensors.

ESSAILEC test blocks are engineered to simplify operations such as current and voltage measurement, monitoring, signal injection, testing, repair and replacement of meters and protection relays. The system uses a coordinated plug-and-base arrangement, enabling test equipment to be connected quickly while permanent installation wiring remains organised and protected.

A key benefit of the ESSAILEC architecture is its make-before-break contact principle. In compatible current-transformer circuits, this allows automatic CT short-circuiting during test operations without requiring separate manually operated sliders or switching components. The system also incorporates coding and reverse-insertion protection to help prevent connection errors during commissioning and maintenance.

Key Advantages

  • Purpose-designed ESSAILEC test and disconnect solution for electrical measurement and protection circuits.
  • Supports current measurement, voltage measurement, monitoring and test-signal injection.
  • Facilitates servicing or replacement of compatible meters and protection relays.
  • Make-before-break contact principle supports safe and efficient test procedures.
  • ESSAILEC architecture can automatically short-circuit compatible current-transformer secondary circuits during testing.
  • Plug-and-play system helps reduce the time required for commissioning and maintenance operations.
  • Mechanical coding and reverse-insertion protection help minimise connection errors.

Key Features

  • TE Connectivity / ENTRELEC ESSAILEC test-block system.
  • M30-D-PWA manufacturer designation.
  • Also referenced as M30PWA.
  • Designed for disconnect and measurement applications.
  • Suitable for secondary circuits associated with current and voltage measurement.
  • Supports testing of measurement and protection equipment.
  • ESSAILEC plug-and-base architecture.
  • Make-before-break contact principle within compatible ESSAILEC test circuits.
  • Coding system helps prevent connection between incompatible circuits.
  • Protection against reverse plug insertion.
  • Designed for professional industrial test and maintenance applications.

Safe and Efficient ESSAILEC Testing

Electrical measurement and protection circuits often need to be tested without unnecessarily disturbing permanent wiring or interrupting associated equipment. The M30-D-PWA forms part of the ESSAILEC system developed specifically for this purpose, providing an engineered interface for connecting test equipment to secondary current and voltage circuits.

The ESSAILEC make-before-break principle is particularly valuable in current-transformer applications. When used in the appropriate ESSAILEC circuit configuration, the system automatically establishes the required short circuit before opening the measurement path, avoiding the need to operate separate shorting links manually. This helps engineers perform commissioning, diagnostic and maintenance procedures quickly while maintaining a controlled test sequence.

Typical Applications

  • Current-transformer secondary test circuits.
  • Voltage-transformer secondary test circuits.
  • Electrical metering installations.
  • Protection relay testing and maintenance.
  • Current and voltage measurement systems.
  • Substation protection and control panels.
  • Power distribution and switchgear assemblies.
  • Industrial monitoring and instrumentation systems.
  • Commissioning and diagnostic test interfaces.

Technical Specifications

Tick the specs you need, then view products that match.

Number of Levels 1
Connection Screw clamp
Terminal Type Disconnect / Test
Product Series TE Essailec
Manufacturer TE Connectivity / ENTRELEC
Series ESSAILEC
Model M30-D-PWA
Alternative model M30PWA
Part number 1SNA116861R1300
Product type Test and disconnect block
Function Disconnect and measurement
System type ESSAILEC test-block system
Test functions Current measurement, voltage measurement, monitoring and signal injection
Service applications Testing, repair and replacement of compatible meters and protection relays
Contact principle Make-before-break
Mounting compatibility TH35 / G32 rail profiles
Insertion protection Reverse-insertion protection
EAN / GTIN 3472591168617
Country of origin France
Customs tariff 85369010
Factory pack quantity 10 pieces
Product status Active
EU RoHS Compliant

Frequently Asked Questions

What is the TE Connectivity M30-D-PWA 1SNA116861R1300?

It is an ENTRELEC ESSAILEC test and disconnect block designed for testing, measurement and maintenance operations in secondary current and voltage circuits.

What can the M30-D-PWA ESSAILEC test block be used for?

ESSAILEC test blocks support operations including current and voltage measurement, monitoring, test-signal injection and servicing or replacement of compatible meters and protection relays.

How does the ESSAILEC make-before-break principle help with current-transformer testing?

In a compatible ESSAILEC current-transformer circuit, the contact sequence allows the required CT secondary short circuit to be established before the measurement circuit is opened, helping provide a controlled test procedure without manually operating separate shorting elements.

Does the ESSAILEC system provide protection against incorrect plug insertion?

Yes. The ESSAILEC architecture incorporates plug-and-base coding and protection against reverse insertion, helping reduce the possibility of incorrect connections between test circuits.

What are the identification details for 1SNA116861R1300?

The product is identified as M30-D-PWA, also referenced as M30PWA, with TE Connectivity / ENTRELEC part number 1SNA116861R1300 and EAN / GTIN 3472591168617.

Trusted ESSAILEC Test Connection Technology

TE Connectivity ENTRELEC ESSAILEC test blocks provide purpose-designed interfaces for measurement and protection circuits, helping engineers carry out commissioning, testing and maintenance while preserving organised and serviceable electrical installations.