1sna007011r1100 - surge protector 153vdc

1sna007011r1100 – surge protector 153vdc

TE Connectivity 1SNA007011R1100 M4/9.PV130/60 is a compact screw-clamp surge protection terminal block with a maximum operating voltage of 153 V DC for industrial control and automation circuits.

SKU: 1SNA007011R1100Alt SKU: SURGE PROTECTOR 153VDCMPN: 1SNA007011R1100
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the TE Connectivity 1SNA007011R1100 Surge Protector?

The TE Connectivity 1SNA007011R1100, type M4/9.PV130/60, is a compact DIN rail surge protection terminal block designed to protect sensitive electrical and electronic circuits against transient overvoltages. Originally part of the Entrelec terminal block range, this component combines surge suppression with a practical screw-clamp terminal format for industrial control and automation installations.

The M4/9.PV130/60 provides a maximum operating voltage of 153 V DC and uses varistor-based surge protection to limit transient voltage peaks. Its narrow 9 mm spacing allows surge protection to be incorporated efficiently into densely populated control panels and terminal assemblies.

With a grey housing, screw-clamp connection technology and compact dimensions of approximately 65.5 × 9 × 52 mm, the 1SNA007011R1100 is well suited to industrial automation, instrumentation, control circuits and electrical panels where dependable low-power surge suppression is required.

Key Advantages

  • Provides surge protection for DC control and signal circuits.
  • 153 V DC maximum operating voltage for compatible applications.
  • Varistor-based protection helps suppress transient overvoltages.
  • Compact 9 mm terminal spacing saves DIN rail space.
  • Reliable screw-clamp connection for industrial wiring.
  • Suitable for control panels, automation systems and instrumentation circuits.

Key Features

  • TE Connectivity / Entrelec M4/9.PV130/60 surge protection terminal block.
  • 153 V DC maximum operating voltage.
  • 115 V AC maximum operating voltage.
  • 2500 A maximum impulse current with an 8/20 µs waveform.
  • Varistor voltage approximately 162–198 V at 1 mA DC.
  • 300 V peak clamping voltage at the specified test conditions.
  • 550 pF capacitance.
  • Screw-clamp connection technology.
  • Grey industrial terminal-block housing.

Reliable Surge Protection for Control Circuits

Transient overvoltages can be generated by switching operations, inductive loads and other electrical disturbances within industrial systems. Surge protection devices help limit these short-duration voltage peaks before they can damage sensitive control, measurement or automation equipment.

The TE Connectivity M4/9.PV130/60 integrates surge suppression into a compact terminal-block format, allowing protection to be installed directly alongside other DIN rail connection components. Its screw-clamp construction and narrow profile make it particularly suitable for structured industrial panel wiring.

Typical Applications

  • Industrial control panels and cabinets.
  • PLC and automation control circuits.
  • Instrumentation and measurement systems.
  • Low-power DC control circuits.
  • Process control equipment.
  • DIN rail terminal assemblies.
  • Industrial machinery and electrical distribution panels.

Technical Specifications

Tick the specs you need, then view products that match.

Terminal Type Component (diode/LED)
Connection Screw clamp
Product Series TE SNA
Colour Grey
Manufacturer TE Connectivity / Entrelec
Model M4/9.PV130/60
MPN 1SNA007011R1100
Product type Surge protection terminal block / component holder
Function Surge protection
Maximum operating voltage DC 153 V DC
Maximum operating voltage AC 115 V AC
Maximum impulse current 2500 A (8/20 µs)
Varistor voltage at 1 mA DC 162–198 V
Peak clamping voltage 300 V
Capacitance 550 pF
Connection type Screw clamp
Spacing 9 mm
Colour Grey
Dimensions (H × W × D) 65.5 × 9 × 52 mm
Net weight 0.02 kg
Flammability rating UL94 V2
EAN 3472590070119

Frequently Asked Questions

What is the TE Connectivity 1SNA007011R1100 used for?

It is a surge protection terminal block designed to suppress transient overvoltages in industrial control, automation and instrumentation circuits.

What is the maximum DC operating voltage?

The M4/9.PV130/60 has a maximum operating voltage of 153 V DC.

What type of connection does the 1SNA007011R1100 use?

It uses a reliable screw-clamp connection suitable for industrial terminal-block installations.

What is the impulse current rating?

The surge protector is rated for a maximum impulse current of 2500 A using an 8/20 µs current waveform.

How wide is the M4/9.PV130/60?

The unit has a width and terminal spacing of 9 mm, allowing compact installation on a DIN rail.

Trusted Industrial Connection and Protection Technology

TE Connectivity and Entrelec terminal-block solutions are widely used in industrial control and automation systems where compact installation, secure electrical connections and dependable circuit protection are essential.