Partex COL50-8 is a copper tube crimp ring terminal for terminating 50 mm² electrical conductors onto M8 stud connections, supplied in packs of 50 for industrial electrical installations, power distribution and panel wiring applications.
£36.02
The Partex COL50-8 is a copper tube ring terminal designed for terminating 50 mm² electrical conductors onto an M8 threaded stud or bolted electrical connection. Supplied in a convenient pack of 50 terminals, this cable lug provides a practical solution for creating secure, mechanically fastened electrical connections in power distribution equipment, industrial control panels and electrical installations.
The terminal features a copper tubular crimp barrel and a closed-ring mounting eye. The barrel accommodates a correctly sized electrical conductor for crimp termination, while the M8 ring connection allows the completed cable assembly to be fastened to a compatible threaded stud or bolt. The copper construction provides an electrically conductive connection between the conductor and the equipment termination point.
With its 50 mm² conductor compatibility, M8 stud size and conventional ring terminal configuration, the Partex COL50-8 is suitable for electrical contractors, industrial panel builders and maintenance engineers requiring consistent cable termination solutions. The pack of 50 supports electrical equipment manufacturing, installation and maintenance operations.
Copper tube ring terminals provide a practical method of connecting electrical conductors to equipment terminals, busbar connection points and threaded studs. The Partex COL50-8 combines a tubular crimp barrel with a closed-ring mounting eye, allowing a correctly prepared 50 mm² conductor to be terminated and mechanically fastened to a compatible M8 electrical connection. The closed-ring configuration provides positive mechanical retention around the stud while the fastening remains secured.
For dependable installation, the conductor should be prepared and crimped using tooling and dies suitable for the terminal design and conductor size. The completed ring terminal must then be fastened according to the equipment manufacturer's instructions. Correct crimping, cable selection and fastening are essential for maintaining electrical continuity and reducing the risk of loose or overheated connections. The completed assembly must also be suitable for the intended electrical load, operating conditions and mechanical requirements.
Tick the specs you need, then view products that match.
| Material | Copper | |
|---|---|---|
| Conductor Size | 50 mm² | |
| Stud Size | M8 | |
| Device Type | Copper Tube Lug | |
| Manufacturer | Partex | |
| Model / Part number | COL50-8 | |
| Product type | Copper tube ring terminal | |
| Terminal configuration | Ring cable lug | |
| Material | Copper | |
| Nominal conductor cross-section | 50 mm² | |
| Stud size | M8 | |
| Termination type | Crimp | |
| Barrel type | Tubular | |
| Connection type | Bolted or stud-mounted ring connection | |
| Packaging | Pack | |
| Quantity per pack | 50 | |
| Application | Electrical cable termination and conductor connection | |
| HS Code | 74031900 |
The Partex COL50-8 is a copper tube ring terminal used to terminate 50 mm² electrical conductors onto compatible M8 stud or bolted connections in electrical equipment, power distribution panels and industrial installations.
The terminal is designed for a nominal conductor cross-section of 50 mm².
The Partex COL50-8 is designed for an M8 threaded stud or compatible bolted electrical connection.
The terminal is manufactured from copper, providing an electrically conductive connection between the terminated conductor and the equipment connection point.
Each pack contains 50 Partex COL50-8 copper tube ring terminals.
The correctly sized conductor is inserted into the tubular barrel and crimped using suitable tooling. The ring eye is then positioned over a compatible M8 stud or bolt and secured according to the equipment manufacturer's installation instructions.
Yes, the COL50-8 can be used for suitable 50 mm² conductor connections in electrical distribution equipment where an M8 fastening is provided, provided the terminal, conductor and completed connection meet the installation's electrical and mechanical requirements.
Both terminals are designed for M8 stud connections. The COL35-8 accommodates 35 mm² conductors, while the COL50-8 accommodates 50 mm² conductors. The appropriate terminal must be selected according to the conductor cross-section and equipment connection requirements.
The crimping tool and die must be suitable for the 50 mm² copper tube terminal and the conductor being terminated. Correct crimping equipment and procedures should be selected according to the terminal manufacturer's recommendations.
Partex cable identification and connection products support the practical requirements of electrical contractors, panel builders, automation engineers and industrial maintenance professionals. The COL50-8 copper tube ring terminal provides a convenient solution for terminating 50 mm² conductors onto M8 electrical connections, with 50 terminals supplied per pack for electrical installation, panel assembly and maintenance work.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.