ABB 1SDA107672R1 is a 630 A external neutral current transformer designed for compatible SACE Tmax XT6 circuit breakers with Ekip Dip electronic trip units in IEC applications.
£477.17
The ABB 1SDA107672R1 EXT CT N XT6 630 A EKIP DIP IEC is an external neutral current transformer designed for use with compatible ABB SACE Tmax XT6 circuit breakers equipped with Ekip Dip electronic trip units. This dedicated accessory enables the protection system to monitor current in an external neutral conductor where the application requires neutral-current sensing.
Designed specifically for the ABB SACE Tmax XT6 platform, the current transformer is rated for 630 A applications and provides the neutral-current measurement input required by compatible Ekip Dip protection configurations. It is particularly useful where the neutral conductor is external to the circuit breaker but must still be included within the electrical protection scheme.
The 1SDA107672R1 is an IEC-version external neutral current transformer manufactured as a dedicated ABB circuit-breaker accessory. Its application-specific design simplifies integration with the appropriate XT6 and Ekip Dip equipment while maintaining the coordinated sensing architecture of the ABB protection system.
In electrical distribution systems where the neutral conductor is not routed through the circuit breaker, an external neutral current transformer allows the compatible electronic protection system to obtain the neutral-current measurement required for its configured protection functions. The transformer senses current flowing through the external neutral and provides the corresponding input to the compatible Ekip Dip protection system.
Using the dedicated ABB transformer helps maintain compatibility between the sensing component, XT6 circuit breaker and Ekip Dip electronic trip unit. The 1SDA107672R1 is therefore a purpose-designed solution for installations requiring external neutral sensing within an ABB SACE Tmax XT6 protection architecture.
| Series | SACE Tmax XT |
|---|---|
| Product | EXT CT N XT6 630 A EKIP DIP IEC |
| ABB order code | 1SDA107672R1 |
| Product type | External neutral current transformer |
| Application | External neutral-current sensing |
| Compatible breaker frame | XT6 |
| Rated current | 630 A |
| Trip-unit family | Ekip Dip |
| Configuration | IEC |
| Reference standard | IEC 60947-2 |
| Weight | 0.1 kg |
| GTIN / EAN | 8015644103255 |
The ABB 1SDA107672R1 is an external neutral current transformer used with compatible XT6 circuit breakers and Ekip Dip electronic trip units to provide neutral-current sensing.
The external neutral current transformer is designed for a 630 A XT6 application.
It is designed for compatible ABB SACE Tmax XT6 circuit-breaker configurations using an Ekip Dip electronic trip unit.
An external neutral current transformer allows a compatible protection system to sense current in a neutral conductor located outside the circuit breaker, enabling that neutral current to be included in the configured protection scheme.
The 1SDA107672R1 is an IEC configuration, with ABB specifying IEC 60947-2 as its reference standard.
ABB SACE Tmax XT accessories are engineered to integrate with compatible circuit breakers and electronic trip units, helping create coordinated and dependable protection systems for industrial and commercial low-voltage distribution.