1SDA107615R1 ABB Ekip G Dip LS/I 630 A XT6 4-Pole Generator Protection Trip Unit

1SDA107615R1 ABB Ekip G Dip LS/I 630 A XT6 4-Pole Generator Protection Trip Unit

ABB 1SDA107615R1 is a 630 A four-pole Ekip G Dip LS/I electronic trip unit for compatible Tmax XT6 circuit breakers, providing dedicated long-time, short-time and instantaneous overcurrent protection for generator applications up to 690 V AC.

SKU: 1SDA107615R1MPN: 1SDA107615R1
Price
List Price £1,444.51 ex VAT
Your Price (ex VAT) Save 25%
£1,083.38 25% OFF
You save £361.13 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,083.38
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,083.38

Why Choose the ABB 1SDA107615R1 Ekip G Dip LS/I Trip Unit?

The ABB 1SDA107615R1 is a 630 A Ekip G Dip LS/I electronic trip unit designed for generator protection applications with compatible ABB SACE Tmax XT6 moulded-case circuit breakers. Featuring a four-pole configuration, this electronic release provides dedicated protection characteristics for low-voltage AC generator circuits.

The Ekip G Dip LS/I is specifically designed for generator protection, where protection settings must accommodate the electrical characteristics and fault-current behaviour of generating equipment. Its electronic protection functions provide long-time overload, short-time short-circuit and instantaneous short-circuit protection, helping protect generators and associated distribution conductors against damaging overcurrent conditions.

Rated at 630 A with a rated operational voltage of 690 V AC, the 1SDA107615R1 is designed for the ABB Tmax XT6 platform. It is supplied as a loose or configurable electronic release for association with a compatible XT6 breaking part, allowing the required breaking capacity and generator-specific protection characteristics to be combined within the modular Tmax XT system.

Key Advantages

  • Dedicated Ekip G Dip electronic protection for generator applications.
  • 630 A rated current for substantial generator and distribution circuits.
  • Four-pole configuration for compatible three-phase and neutral arrangements.
  • Provides long-time, short-time and instantaneous overcurrent protection.
  • Generator-specific protection characteristics support reliable operation with generating equipment.
  • 690 V AC rated operational voltage.
  • Modular design allows pairing with an appropriate ABB Tmax XT6 breaking part.

Key Features

  • ABB SACE Tmax XT6 Ekip G Dip series.
  • 630 A rated current.
  • Four-pole configuration.
  • Ekip G Dip LS/I electronic release.
  • Long-time overload protection (L).
  • Short-time short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Specifically designed for generator protection.
  • 690 V AC rated operational voltage.
  • Electronic release technology.
  • Loose or configurable installation format.
  • Compatible with the ABB SACE Tmax XT6 platform.

Dedicated Electronic Protection for Generator Circuits

Generator circuits have different protection requirements from conventional utility-fed distribution circuits because available short-circuit current can be limited by the generator itself. The ABB Ekip G Dip LS/I is designed specifically for generator applications, providing electronic long-time, short-time and instantaneous protection characteristics suited to protecting generating equipment and its associated conductors.

The modular Tmax XT6 architecture allows the 1SDA107615R1 to be combined with the appropriate XT6 breaking part for the required short-circuit performance. This gives panel builders and electrical engineers flexibility when configuring generator switchboards, standby power systems and other low-voltage generation installations.

Typical Applications

  • Low-voltage generator protection systems.
  • Standby and emergency generator switchboards.
  • Industrial generating sets.
  • Commercial and infrastructure standby power systems.
  • Four-pole generator distribution circuits.
  • Generator incomers and associated distribution assemblies.
  • Industrial installations with local generation.

Technical Specifications

Series SACE Tmax XT
Order code 1SDA107615R1
EAN 8015644102685
Product type Electronic trip unit / Tmax XT accessory
Compatible frame Tmax XT6
Rated current (In) 630 A
Number of poles 4
Current type AC
Rated operational voltage 690 V AC
Trip-unit type Ekip G Dip LS/I
Release type Electronic (EL)
Protection functions Long-time, short-time and instantaneous (LS/I)
Circuit-breaker application Generator protection
Configuration type Loose or configurable
Suitable for ABB Tmax XT6
Standard IEC 60947-2
Product net weight 1.6 kg
Package dimensions (W × H × D) 120 × 160 × 190 mm
Package gross weight 1.7 kg
ABB product group T-Max XT 250 Range

Frequently Asked Questions

What is the ABB 1SDA107615R1 used for?

The ABB 1SDA107615R1 is a 630 A four-pole Ekip G Dip LS/I electronic trip unit designed for generator protection with compatible ABB Tmax XT6 circuit breakers.

What protection functions does the Ekip G Dip LS/I provide?

The Ekip G Dip LS/I provides long-time overload, short-time short-circuit and instantaneous short-circuit protection with characteristics intended for generator applications.

What is the rated current and voltage of ABB 1SDA107615R1?

The 1SDA107615R1 has a rated current of 630 A and a rated operational voltage of 690 V AC.

Is ABB 1SDA107615R1 a four-pole trip unit?

Yes. The 1SDA107615R1 is a four-pole Ekip G Dip LS/I release designed for compatible ABB Tmax XT6 generator-protection circuit-breaker configurations.

Is the ABB 1SDA107615R1 a complete circuit breaker?

No. The 1SDA107615R1 is an Ekip G Dip LS/I electronic trip unit designed to be combined with an appropriate ABB Tmax XT6 breaking part to create the required generator-protection circuit-breaker configuration.

Trusted ABB Generator Protection Technology

ABB SACE Tmax XT generator protection solutions combine modular circuit-breaker architecture with dedicated Ekip G electronic protection, supporting dependable overload and short-circuit protection for low-voltage generator installations.