1SDA107610R1 ABB TMA 630-6300 XT6 4P InN=50%In

1SDA107610R1 ABB TMA 630-6300 XT6 4P InN=50%In

ABB 1SDA107610R1 is a 630 A four-pole TMA thermomagnetic trip unit for compatible SACE Tmax XT6 circuit-breaker units, providing adjustable thermal and 3150–6300 A magnetic protection with neutral protection at 50% of the phase setting.

SKU: 1SDA107610R1MPN: 1SDA107610R1
Price
List Price £1,348.20 ex VAT
Your Price (ex VAT) Save 25%
£1,011.15 25% OFF
You save £337.05 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,011.15
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,011.15

Why Choose the ABB 1SDA107610R1 TMA 630-6300 XT6 4P Trip Unit?

The ABB 1SDA107610R1, designated TMA 630-6300 XT6 4p InN=50%In, is a four-pole thermomagnetic protection trip unit designed for compatible ABB SACE Tmax XT6 circuit-breaker units. Rated at 630 A, it provides adjustable thermal overload protection and adjustable magnetic short-circuit protection for low-voltage power distribution applications.

The TMA trip unit offers a thermal adjustment range of 0.7–1 × In, corresponding to approximately 441–630 A at the 630 A nominal rating. Its magnetic protection is adjustable from 5–10 × In, corresponding to 3150–6300 A, allowing the protection characteristics to be matched to the requirements of the protected distribution circuit.

This 1SDA107610R1 version is specifically configured for four-pole XT6 applications with neutral protection at 50% of the phase setting. It is supplied as a separate protection trip unit and must be combined with a compatible four-pole XT6 breaking unit to form a complete circuit breaker.

Key Advantages

  • Genuine ABB SACE Tmax XT6 thermomagnetic trip unit.
  • 630 A nominal current for high-capacity distribution applications.
  • Adjustable thermal overload protection from 0.7–1 × In.
  • Adjustable magnetic protection from 5–10 × In.
  • Magnetic short-circuit setting range of 3150–6300 A.
  • Four-pole configuration with 50% neutral protection.
  • Designed to combine with a compatible ABB XT6 four-pole breaking unit.

Key Features

  • ABB SACE Tmax XT6 protection accessory.
  • Trip unit type: TMA thermomagnetic.
  • Nominal current: 630 A.
  • Thermal adjustment: 0.7–1 × In.
  • Thermal setting range: approximately 441–630 A.
  • Magnetic adjustment: 5–10 × In.
  • Magnetic setting range: 3150–6300 A.
  • Number of poles: 4.
  • Neutral protection: 50% of phase setting.
  • Separate trip unit for use with a compatible XT6 breaking unit.

Adjustable Thermomagnetic Protection for the XT6 Platform

The ABB TMA protection system combines two established protection principles in a single trip unit. The thermal element responds to sustained overload conditions and can be adjusted from 0.7 to 1 times the 630 A nominal current, while the magnetic element responds rapidly to high short-circuit currents and can be adjusted from 5 to 10 times the nominal current.

For four-wire systems, the 1SDA107610R1 incorporates 50% neutral protection. This distinguishes it from the corresponding full-neutral version and makes selection of the correct order code important when configuring an XT6 circuit breaker. As a separate trip unit, the 1SDA107610R1 must be paired with a suitable four-pole XT6 breaking unit rather than being treated as a complete standalone MCCB.

Typical Applications

  • ABB SACE Tmax XT6 circuit-breaker assemblies.
  • Industrial low-voltage power distribution systems.
  • Main and sub-distribution switchboards.
  • Commercial and infrastructure electrical distribution.
  • Four-wire systems requiring reduced neutral protection.
  • Feeder and distribution circuit protection.
  • Applications requiring adjustable thermal and magnetic protection.
  • Configurable XT6 circuit breakers assembled from separate breaking and protection units.

Technical Specifications

Series SACE Tmax XT / Tmax XT 250 Range
Order code 1SDA107610R1
Product type Thermomagnetic trip unit
Compatible circuit-breaker family SACE Tmax XT6
Trip unit TMA
Protection technology Thermomagnetic
Nominal current In 630 A
Thermal protection adjustment 0.7–1 × In
Thermal protection range approximately 441–630 A
Magnetic protection adjustment 5–10 × In
Magnetic protection range 3150–6300 A
Number of poles 4
Neutral protection 50% of phase setting
Neutral designation InN=50%In
Application Power distribution protection
Installation Combined with a compatible XT6 four-pole breaking unit
Product weight 1.3 kg
Minimum order quantity 1 piece
EAN / GTIN 8015644102630

Frequently Asked Questions

What is the ABB 1SDA107610R1?

The 1SDA107610R1 is a 630 A four-pole TMA thermomagnetic trip unit for compatible ABB SACE Tmax XT6 circuit-breaker units, with adjustable thermal and magnetic protection and 50% neutral protection.

Is the ABB 1SDA107610R1 a complete circuit breaker?

No. The 1SDA107610R1 is the thermomagnetic protection trip unit. It must be combined with a compatible four-pole ABB XT6 breaking unit to create the complete circuit-breaker assembly.

What are the adjustment ranges of the TMA 630-6300 trip unit?

The thermal protection is adjustable from 0.7–1 × In, approximately 441–630 A for this 630 A unit, while the magnetic protection is adjustable from 5–10 × In, corresponding to 3150–6300 A.

What does InN=50%In mean on the ABB 1SDA107610R1?

InN=50%In identifies a four-pole configuration with neutral protection set at 50% of the phase setting. The 1SDA107610R1 is therefore the reduced-neutral version of the 630 A XT6 TMA trip unit.

Which ABB circuit-breaker family is compatible with the 1SDA107610R1?

The 1SDA107610R1 is designed for the ABB SACE Tmax XT6 platform and must be combined with a compatible four-pole XT6 breaking unit.

Trusted ABB Tmax XT Protection

ABB SACE Tmax XT protection units provide configurable circuit protection for low-voltage distribution systems, with the 1SDA107610R1 delivering 630 A adjustable thermomagnetic protection and 50% neutral protection for compatible four-pole XT6 circuit-breaker assemblies.