Why Choose the ABB Ekip Hi-Touch LSI E1.2..E6.2 Ed.2?

The ABB 1SDA107532R1 Ekip Hi-Touch LSI E1.2..E6.2 Ed.2 is an advanced electronic protection trip unit designed for use with ABB SACE Emax 2 air circuit breakers. Part of the high-performance ABB Ekip Hi-Touch range, it provides sophisticated protection, measurement and monitoring capabilities for demanding low-voltage electrical distribution applications.

Designed for Emax 2 frame sizes E1.2 through E6.2, the Ekip Hi-Touch LSI combines configurable electronic protection with an intuitive touchscreen interface. Its LSI functionality provides long-time, short-time and instantaneous overcurrent protection, helping protect electrical installations against overload and short-circuit conditions while enabling precise coordination within power distribution systems.

The 1SDA107532R1 is the black-platform Ed.2 version of the Ekip Hi-Touch LSI for compatible ABB SACE Emax 2 circuit breakers. Its modular architecture supports compatible Ekip communication, signalling and power supply accessories, making it suitable for sophisticated industrial, infrastructure and commercial power distribution systems.

Key Advantages

  • Advanced LSI electronic protection for demanding low-voltage power distribution applications.
  • Suitable for ABB SACE Emax 2 E1.2, E2.2, E4.2 and E6.2 air circuit breakers.
  • Ekip Hi-Touch functionality for advanced protection, measurement and system monitoring.
  • Provides long-time, short-time and instantaneous overcurrent protection functions.
  • Touchscreen interface simplifies protection settings, measurements and diagnostics.
  • Compatible with ABB’s modular Ekip communication and accessory ecosystem.

Key Features

  • ABB Ekip Hi-Touch LSI electronic trip unit.
  • ABB order code 1SDA107532R1.
  • Black-platform Ed.2 version.
  • LSI protection functions for overload and short-circuit protection.
  • Long-time (L), short-time (S) and instantaneous (I) protection.
  • Touchscreen-based interface for configuration and operating information.
  • Suitable for Emax 2 E1.2 through E6.2 circuit breaker frames.
  • Supports compatible Ekip communication, signalling and power supply modules.

Advanced Protection for Emax 2 Circuit Breakers

Electronic trip units continuously monitor electrical conditions and initiate circuit breaker operation when configured protection thresholds are exceeded. The ABB Ekip Hi-Touch LSI provides long-time, short-time and instantaneous protection functions, allowing engineers to configure sophisticated protection strategies for low-voltage power distribution systems.

The Ekip Hi-Touch range extends the capabilities of the Emax 2 platform with advanced protection, measurement and monitoring functionality. Its modular architecture can also support compatible Ekip communication and signalling accessories, helping integrate circuit breakers into modern electrical monitoring, energy management and industrial automation systems.

Typical Applications

  • ABB SACE Emax 2 air circuit breaker installations.
  • Industrial low-voltage power distribution systems.
  • Main and secondary electrical distribution switchboards.
  • Commercial buildings and infrastructure installations.
  • Manufacturing and process industry switchgear.
  • Power distribution systems requiring advanced LSI protection and selectivity.

Technical Specifications

Series Ekip Hi-Touch
Order code 1SDA107532R1
EAN 8015644101909
Product type Electronic protection trip unit
Protection functions LSI – Long-time, Short-time and Instantaneous
Platform Black Platform
Edition Ed.2
Configuration type Loose or configurable
Suitable for E1.2, E2.2, E4.2 and E6.2
Suitable product class ABB SACE Emax 2 air circuit breakers
Product group Emax2 Air Circuit Breaker
Standard platform IEC / UL
Weight approx. 0.2 kg

Frequently Asked Questions

What is the ABB 1SDA107532R1 used for?

The ABB 1SDA107532R1 is an Ekip Hi-Touch LSI electronic trip unit used to provide advanced configurable protection for compatible ABB SACE Emax 2 air circuit breakers.

Which circuit breakers are compatible with the ABB 1SDA107532R1?

The trip unit is designed for compatible ABB SACE Emax 2 E1.2, E2.2, E4.2 and E6.2 circuit breakers.

What does LSI mean on the Ekip Hi-Touch trip unit?

LSI refers to Long-time, Short-time and Instantaneous protection functions, providing configurable protection against overload and short-circuit conditions.

Is the 1SDA107532R1 a black-platform Ekip trip unit?

Yes. The ABB 1SDA107532R1 Ekip Hi-Touch LSI E1.2..E6.2 Ed.2 is a black-platform electronic trip unit for the Emax 2 range.

Can the Ekip Hi-Touch LSI integrate with additional ABB Ekip modules?

Yes. The Ekip Hi-Touch platform supports compatible ABB Ekip accessories and modules, allowing communication, signalling and other system capabilities to be added according to the requirements of the Emax 2 installation.

Advanced ABB Circuit Protection Technology

ABB Ekip Hi-Touch trip units form part of the SACE Emax 2 circuit breaker platform, providing advanced electronic protection, measurement and integration capabilities for demanding low-voltage power distribution systems.