1SDA105158R1 ABB EXT CT N XT6 800 A Ekip Dip External Neutral Current Sensor

1SDA105158R1 ABB EXT CT N XT6 800 A Ekip Dip External Neutral Current Sensor

ABB 1SDA105158R1 external neutral current sensor for compatible SACE Tmax XT6 800 A circuit breakers with Ekip Dip electronic trip units in IEC and UL applications.

SKU: 1SDA105158R1MPN: 1SDA105158R1
Price
List Price £636.23 ex VAT
Your Price (ex VAT) Save 25%
£477.17 25% OFF
You save £159.06 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £477.17
Trade pricing is personalised to your account

Manufacturer Lead Time

£477.17

Why Choose the ABB 1SDA105158R1 External Neutral Current Sensor?

The ABB 1SDA105158R1, designated EXT CT N XT6 800 A EKIP DIP IEC/UL, is an external neutral current sensor for ABB SACE Tmax XT6 circuit breakers. Designed for use with compatible Ekip Dip electronic trip units, it enables the neutral conductor current to be measured externally as part of the circuit breaker's protection system.

This genuine ABB accessory is rated for 800 A applications and is specifically associated with the XT6 frame size. External neutral current sensing is used in installations where neutral current monitoring must be incorporated into the protection arrangement, particularly in systems where the neutral conductor is external to the circuit breaker poles.

The 1SDA105158R1 is designed for IEC and UL applications, with reference standards including IEC 60947-2 and UL 489. As part of the ABB SACE Tmax XT accessory platform, it provides a manufacturer-matched solution for integrating external neutral current measurement with compatible XT6 800 A Ekip Dip circuit breaker configurations.

Key Advantages

  • Genuine ABB external neutral current sensor for SACE Tmax XT equipment.
  • Designed specifically for ABB Tmax XT6 800 A circuit breakers.
  • Compatible with appropriate Ekip Dip electronic trip units.
  • Enables external neutral conductor current measurement for the protection system.
  • Suitable for both IEC and UL applications.
  • Purpose-designed for integration with ABB's Tmax XT circuit breaker platform.

Key Features

  • ABB SACE Tmax XT electrical accessory.
  • External neutral current sensor configuration.
  • Compatible with XT6 frame size.
  • Designed for 800 A circuit breaker applications.
  • Compatible with appropriate Ekip Dip protection units.
  • Provides current sensing for an external neutral conductor.
  • Designed for IEC 60947-2 applications.
  • Suitable for UL 489 applications.

Reliable External Neutral Current Sensing for Circuit Protection

External neutral current sensors allow the circuit breaker protection system to monitor current flowing through a neutral conductor that is not directly routed through the breaker's main poles. The measured neutral current can therefore be incorporated into the compatible electronic trip unit's protection arrangement, supporting appropriate protection of multi-phase distribution systems.

The ABB 1SDA105158R1 is specifically matched to the XT6 800 A platform and compatible Ekip Dip trip units. Its dedicated ABB design provides a practical solution for switchboards and power distribution systems requiring external neutral current measurement while maintaining compatibility with the SACE Tmax XT protection architecture.

Typical Applications

  • ABB SACE Tmax XT6 800 A circuit breaker installations.
  • XT6 circuit breakers equipped with compatible Ekip Dip trip units.
  • External neutral conductor current measurement.
  • Industrial low-voltage switchboards.
  • Commercial and industrial power distribution systems.
  • IEC and UL circuit breaker protection applications requiring neutral current sensing.

Technical Specifications

Product range SACE Tmax XT
Product group T-Max XT 250 Range
Model / designation EXT CT N XT6 800 A EKIP DIP IEC/UL
ABB order code 1SDA105158R1
Alternate catalogue number KXT6CTUDIPA800
UPC / GTIN 8015644072506
Product type External neutral current sensor
Accessory category Circuit breaker electrical accessory
Compatible frame XT6
Rated application current 800 A
Compatible trip unit Ekip Dip
Measurement application External neutral conductor current
Reference standards IEC 60947-2, UL 489
Approvals IEC, UL
RoHS Compliant with EU Directive 2011/65/EU and amendment 2015/863
Weight approx. 0.1 kg

Frequently Asked Questions

What is the ABB 1SDA105158R1 used for?

The ABB 1SDA105158R1 is an external neutral current sensor used with compatible ABB SACE Tmax XT6 800 A circuit breakers and Ekip Dip trip units to measure current in an external neutral conductor.

Which circuit breaker is compatible with the ABB 1SDA105158R1?

The 1SDA105158R1 is designed for the ABB SACE Tmax XT6 frame in compatible 800 A Ekip Dip configurations.

What is the current rating of the ABB 1SDA105158R1?

The external neutral current sensor is intended for 800 A XT6 applications.

Which trip unit is the ABB 1SDA105158R1 designed for?

The accessory is designed for use with compatible ABB Ekip Dip electronic trip units on the Tmax XT6 platform.

Which standards apply to the ABB 1SDA105158R1?

The accessory is suitable for IEC and UL applications, with ABB specifying reference standards including IEC 60947-2 and UL 489.

Trusted ABB Circuit Breaker Accessories

ABB SACE Tmax XT accessories are engineered to integrate with the Tmax XT circuit breaker platform, providing dedicated sensing, protection and control solutions for industrial switchboards and low-voltage power distribution systems.