1SDA104965R1 ABB YU-C XT6 W Undervoltage Release 220–240 V AC / 220–250 V DC

1SDA104965R1 ABB YU-C XT6 W Undervoltage Release 220–240 V AC / 220–250 V DC

ABB 1SDA104965R1 YU-C XT6 W wired undervoltage release rated for 220–240 V AC or 220–250 V DC and designed for ABB SACE Tmax XT6 withdrawable circuit breakers.

SKU: 1SDA104965R1MPN: 1SDA104965R1
Price
List Price £179.23 ex VAT
Your Price (ex VAT) Save 25%
£134.42 25% OFF
You save £44.81 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £134.42
Trade pricing is personalised to your account

Manufacturer Lead Time

£134.42

Why Choose the ABB YU-C XT6 W 1SDA104965R1 Undervoltage Release?

The ABB 1SDA104965R1 is a wired undervoltage release (YU-C) designed for use with ABB SACE Tmax XT6 withdrawable circuit breakers. Part of the ABB Tmax XT accessory range, it provides a reliable means of automatically tripping the circuit breaker when the control supply voltage falls below the required operating level.

Designed specifically for XT6 withdrawable circuit breakers, the YU-C undervoltage release integrates directly with the breaker mechanism to support electrical protection, remote control and safety functions in low-voltage distribution systems. Its wired configuration is intended for dependable installation within industrial switchboards, distribution panels and machinery control assemblies.

The 1SDA104965R1 is rated for a 220–240 V AC or 220–250 V DC control supply and is manufactured in accordance with the relevant ABB Tmax XT circuit-breaker accessory requirements. It is suitable for installations where loss or significant reduction of control voltage must cause the associated XT6 circuit breaker to open.

Key Advantages

  • Genuine ABB wired undervoltage release for SACE Tmax XT circuit breakers.
  • Designed specifically for XT6 withdrawable circuit breakers.
  • Supports 220–240 V AC control supplies.
  • Supports 220–250 V DC control supplies.
  • Automatically enables breaker tripping when the control voltage falls below the permitted operating level.
  • Suitable for industrial switchgear, electrical distribution and machinery protection systems.

Key Features

  • ABB SACE Tmax XT accessory range.
  • YU-C wired undervoltage release.
  • XT6 frame compatibility.
  • Designed for withdrawable circuit-breaker configurations.
  • 220–240 V AC rated voltage.
  • 220–250 V DC rated voltage.
  • Electrical accessory for automatic breaker opening during undervoltage conditions.
  • Designed to IEC and UL circuit-breaker standards.

Reliable Undervoltage Protection for Circuit Breakers

An undervoltage release provides automatic circuit-breaker opening when its control supply falls below the required operating level. This function is commonly used where machinery, switchgear or electrical systems must not remain energised, or must not automatically restart, following a significant loss of control voltage.

The ABB YU-C XT6 wired release is engineered as a dedicated accessory for the SACE Tmax XT6 platform. Its integration with withdrawable XT6 circuit breakers makes it suitable for applications requiring dependable remote tripping, control-voltage supervision and coordinated protection within low-voltage distribution systems.

Typical Applications

  • Low-voltage electrical distribution switchboards.
  • ABB SACE Tmax XT6 withdrawable circuit-breaker installations.
  • Industrial machinery control panels.
  • Motor control centres and power distribution assemblies.
  • Automatic shutdown systems requiring undervoltage protection.
  • Commercial and industrial electrical protection systems.

Technical Specifications

Series SACE Tmax XT
ABB order code 1SDA104965R1
Product type Wired undervoltage release (UVR)
Accessory type Undervoltage Release
Frame size XT6
Circuit-breaker configuration Withdrawable
Rated AC voltage 220–240 V AC
Rated DC voltage 220–250 V DC
Standards IEC 60947-2, UL 489
Compliance RoHS compliant
Weight 0.116 kg
UPC 8056221027274

Frequently Asked Questions

What is the ABB 1SDA104965R1 used for?

The ABB 1SDA104965R1 is a wired undervoltage release used to trip a compatible ABB SACE Tmax XT6 withdrawable circuit breaker when its control supply voltage falls below the required operating level.

Which circuit breaker is the 1SDA104965R1 compatible with?

It is designed for ABB SACE Tmax XT6 withdrawable circuit breakers.

What control voltage does this undervoltage release require?

The release is rated for 220–240 V AC or 220–250 V DC.

What type of accessory is the YU-C XT6 W?

It is a wired undervoltage release (UVR) that interfaces with the circuit-breaker operating mechanism to provide automatic tripping under undervoltage conditions.

Where is the ABB 1SDA104965R1 typically installed?

It is typically installed as an electrical accessory within an ABB XT6 withdrawable circuit-breaker assembly used in industrial switchboards, distribution panels and machinery control systems.

Trusted ABB Circuit Protection Technology

ABB SACE Tmax XT circuit breakers and accessories are engineered for dependable low-voltage power distribution, helping industrial and commercial electrical systems achieve reliable protection, control and operational safety.