ABB 1SDA104810R1 AUX 1S52 is a low-voltage auxiliary contact for tripped indication on compatible SACE Tmax XT7 circuit breakers, designed for AC/DC signalling circuits below 24 V.
£62.74
The ABB 1SDA104810R1 is a dedicated S52 auxiliary contact for tripped indication designed for ABB SACE Tmax XT7 moulded-case circuit breakers. Designated AUX 1S52 24V XT7, it provides one auxiliary contact for signalling a circuit-breaker trip condition to external monitoring, alarm or automation equipment.
As part of the ABB SACE Tmax XT electrical accessory range, the 1SDA104810R1 provides a purpose-designed signalling interface for compatible XT7 installations. The S52 function enables remote indication of a protective trip, helping operators and control systems distinguish a tripped circuit breaker within industrial power distribution equipment.
The auxiliary contact is intended for AC/DC signalling circuits below 24 V and provides one S52 contact. For the XT7 application, the S52 tripping signal is available when a YU or YO2 coil is installed in the dedicated slot, making the accessory suitable for appropriately configured XT7 circuit-breaker systems.
Auxiliary signalling contacts enable circuit-breaker operating information to be transmitted to external control and monitoring equipment. The ABB 1SDA104810R1 provides the S52 function for tripped indication, allowing an appropriately configured XT7 installation to signal when the breaker has operated due to a protective trip.
The contact is designed for low-voltage AC/DC signalling circuits below 24 V. The S52 trip signal on XT7 is available when a YU or YO2 coil is fitted in the dedicated slot, supporting integration with PLC inputs, alarm systems, indication circuits and supervisory equipment.
| Series | SACE Tmax XT |
|---|---|
| ABB order code | 1SDA104810R1 |
| Product type | Circuit breaker auxiliary contact |
| Accessory type | Auxiliary signalling contact |
| Contact designation | S52 |
| Function | Tripped indication |
| Number of auxiliary contacts | 1 |
| Voltage | <24 V AC/DC |
| Current type | AC / DC |
| Compatible frame | XT7 |
| Trip signal requirement | YU or YO2 coil installed in dedicated slot |
| Reference standards | IEC 60947-2 / UL 489 |
| EAN / GTIN | 8056221027045 |
| Weight | approx. 0.127 kg |
The 1SDA104810R1 is an S52 auxiliary contact for tripped indication on compatible ABB SACE Tmax XT7 circuit breakers.
The auxiliary contact is intended for AC/DC signalling circuits below 24 V.
S52 provides tripped indication, enabling the circuit breaker's protective trip condition to be signalled to external monitoring or control equipment.
The auxiliary contact is designed specifically for compatible ABB SACE Tmax XT7 circuit breakers.
Yes. On the XT7, the S52 tripping signal is available when a YU or YO2 coil is installed in the dedicated slot.
ABB SACE Tmax XT auxiliary contacts provide purpose-designed circuit-breaker signalling for low-voltage distribution systems, helping panel builders and automation engineers integrate dependable trip-status monitoring into industrial electrical installations.