1SDA104786R1 ABB AUX-C 1Q + 1SY L 24V DC XT5 F/P

1SDA104786R1 ABB AUX-C 1Q + 1SY L 24V DC XT5 F/P

ABB 1SDA104786R1 AUX-C 1Q + 1SY L 24V DC XT5 F/P is a left-side auxiliary contact assembly for compatible fixed and plug-in SACE Tmax XT5 circuit breakers, providing one open/closed changeover contact and one tripped-indication changeover contact for signalling below 24 V DC.

SKU: 1SDA104786R1MPN: 1SDA104786R1
Price
List Price £73.05 ex VAT
Your Price (ex VAT) Save 25%
£54.79 25% OFF
You save £18.26 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £54.79
Trade pricing is personalised to your account

Manufacturer Lead Time

£54.79

Why Choose the ABB AUX-C 1Q + 1SY L 24V DC XT5 F/P 1SDA104786R1 Auxiliary Contact?

The ABB 1SDA104786R1 is a genuine auxiliary contact assembly for ABB SACE Tmax XT5 circuit breakers, designed to provide remote electrical indication of circuit breaker status. It combines one changeover contact for open/closed indication (1Q) with one changeover contact for tripped indication (1SY), providing two independent status signals for monitoring and control systems.

Designed for voltages below 24 V DC, the AUX-C assembly is intended for compatible fixed and plug-in XT5 circuit breakers. The contacts are wired on the circuit breaker and the assembly is installed on the left-hand side, providing a purpose-designed solution for integrating breaker position and trip status into control panels, PLC systems and remote monitoring equipment.

As an original ABB SACE Tmax XT electrical accessory, the 1SDA104786R1 is designed specifically for the XT5 frame and provides two SPDT changeover auxiliary contacts. It complies with IEC 60947-2 and UL 489, has a net weight of approximately 0.127 kg and provides a compact solution for status signalling in industrial and commercial low-voltage distribution systems.

Key Advantages

  • Provides both open/closed and tripped status indication from a compatible XT5 circuit breaker.
  • Includes one 1Q changeover contact and one 1SY changeover contact.
  • Designed for low-voltage signalling circuits below 24 V DC.
  • Suitable for compatible fixed and plug-in ABB XT5 circuit breakers.
  • Left-hand installation provides a defined mounting position within the breaker accessory system.
  • Original ABB SACE Tmax XT accessory certified for IEC and UL applications.

Key Features

  • ABB SACE Tmax XT accessory range.
  • XT5 frame compatibility.
  • 1Q open/closed changeover contact.
  • 1SY tripped-indication changeover contact.
  • Two SPDT auxiliary contacts in total.
  • Designed for signalling voltage <24 V DC.
  • Suitable for fixed and plug-in (F/P) XT5 configurations.
  • Left-side installation.
  • Wired directly on the compatible circuit breaker.
  • Compliant with IEC 60947-2 and UL 489.

Circuit Breaker Status and Trip Signalling for ABB XT5

Auxiliary contacts allow a circuit breaker to communicate its operating state to external control and monitoring equipment. The 1Q contact provides open/closed position indication, while the 1SY contact provides a separate indication when the circuit breaker has tripped, allowing control systems to distinguish a protective trip from a normal change in breaker position.

The ABB 1SDA104786R1 combines these functions in a compact left-side accessory for compatible fixed and plug-in XT5 circuit breakers. Its low-voltage changeover contacts make it suitable for integration with PLC inputs, indication circuits, alarm systems, building management systems and other remote monitoring equipment requiring reliable breaker status information.

Typical Applications

  • Remote open/closed indication for ABB SACE Tmax XT5 circuit breakers.
  • Remote circuit breaker trip indication and alarm signalling.
  • PLC and industrial automation input circuits.
  • Low-voltage switchboard monitoring systems.
  • Building management and electrical supervision systems.
  • Industrial and commercial power distribution panels.

Technical Specifications

Series SACE Tmax XT
Order code 1SDA104786R1
Alternate catalogue number KXT5AUXCDQYFP
Product type Auxiliary contact assembly
Product main type Electrical and auxiliary contact accessory
Accessory type Auxiliary contacts
Frame size XT5
Auxiliary contacts 2 changeover contacts (SPDT)
Open/closed indication 1Q changeover contact
Tripped indication 1SY changeover contact
Signalling voltage <24 V DC
Installation side Left
Circuit breaker versions Fixed / plug-in (F/P)
Connection Wired on circuit breaker
Suitable for ABB SACE Tmax XT5
Standards IEC 60947-2, UL 489
Certification IEC / UL
RoHS status Compliant with EU Directive 2011/65/EU and Amendment 2015/863
Product net weight 0.127 kg
UPC 8056221026888

Frequently Asked Questions

What is the ABB 1SDA104786R1 used for?

The 1SDA104786R1 is an auxiliary contact assembly for compatible ABB SACE Tmax XT5 circuit breakers, providing separate electrical signals for breaker open/closed status and tripped status.

What do 1Q and 1SY mean on the ABB 1SDA104786R1?

The 1Q contact is a changeover contact used for open/closed circuit breaker indication, while the 1SY contact is a separate changeover contact used for tripped indication.

What voltage is the ABB 1SDA104786R1 designed for?

The auxiliary contact assembly is designed for signalling circuits operating at less than 24 V DC.

Which XT5 circuit breaker versions can use the ABB 1SDA104786R1?

The 1SDA104786R1 is designed for compatible fixed and plug-in ABB SACE Tmax XT5 circuit breakers and is installed on the left-hand side.

Which standards apply to the ABB 1SDA104786R1?

The ABB 1SDA104786R1 auxiliary contact assembly is specified to IEC 60947-2 and UL 489 and carries IEC and UL certification.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT electrical accessories provide switchboard builders, automation engineers and electrical professionals with manufacturer-engineered solutions for circuit breaker status indication, trip signalling and integration into modern low-voltage monitoring and control systems.