1SDA104714R1 ABB Kit W MP XT5 630A 4-Pole Withdrawable Conversion Kit

1SDA104714R1 ABB Kit W MP XT5 630A 4-Pole Withdrawable Conversion Kit

ABB 1SDA104714R1 is a four-pole 630 A conversion kit for configuring a compatible SACE Tmax XT5 circuit breaker as the moving part of a withdrawable IEC/UL installation.

SKU: 1SDA104714R1MPN: 1SDA104714R1
Price
List Price £259.34 ex VAT
Your Price (ex VAT) Save 25%
£194.51 25% OFF
You save £64.84 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £194.51
Trade pricing is personalised to your account

Manufacturer Lead Time

£194.51

Why Choose the ABB Kit W MP XT5 630A 4-Pole Conversion Kit?

The ABB Kit W MP XT5 630A 4p, order code 1SDA104714R1, is a genuine conversion kit for the moving part of a withdrawable ABB SACE Tmax XT5 circuit breaker. Designed for the 630 A XT5 frame, it allows a compatible fixed circuit breaker to be configured as the moving portion of a withdrawable installation.

This conversion kit is specifically designed for four-pole XT5 circuit breakers and forms part of ABB's modular execution and installation system for the SACE Tmax XT range. When used with the appropriate withdrawable fixed part and associated accessories, it enables the breaker to be inserted, withdrawn and serviced without disturbing the permanent switchboard power connections.

The 1SDA104714R1 is rated for a continuous current of 630 A and is suitable for both IEC and UL applications. ABB specifies reference standards including IEC 60947-2 and UL 489, making the kit suitable for compatible industrial and commercial low-voltage switchboard configurations.

Key Advantages

  • Genuine ABB SACE Tmax XT5 conversion kit.
  • Converts a compatible XT5 breaker into the moving part of a withdrawable configuration.
  • Designed for the 630 A XT5 frame.
  • Four-pole configuration for compatible three-phase plus neutral systems.
  • Supports easier circuit-breaker removal, inspection and maintenance.
  • Allows permanent switchboard connections to remain in place when the breaker is withdrawn.
  • Suitable for both IEC and UL applications.

Key Features

  • ABB SACE Tmax XT accessory.
  • XT5 frame compatibility.
  • Withdrawable moving-part conversion kit.
  • 630 A rated uninterrupted current.
  • 4-pole configuration.
  • Loose / configurable accessory.
  • Designed for compatible ABB XT5 withdrawable assemblies.
  • Reference standards IEC 60947-2 and UL 489.
  • Suitable for IEC and UL circuit-breaker installations.

Reliable Conversion to a Withdrawable XT5 Configuration

Withdrawable circuit-breaker systems separate the removable breaker from the permanently connected fixed part in the switchboard. The ABB 1SDA104714R1 provides the components required to configure a compatible four-pole XT5 630 A breaker as the moving part of such an installation.

This arrangement can simplify maintenance and replacement because the breaker can be withdrawn from the fixed interface without disconnecting the main switchboard conductors. Used with the appropriate ABB fixed part and compatible accessories, the kit supports flexible and serviceable low-voltage distribution assemblies.

Typical Applications

  • ABB SACE Tmax XT5 withdrawable circuit-breaker assemblies.
  • Conversion of compatible XT5 breakers to withdrawable moving-part configuration.
  • Industrial low-voltage switchboards.
  • Main and sub-distribution panels.
  • Four-pole three-phase plus neutral distribution systems.
  • Commercial and infrastructure power-distribution equipment.
  • IEC and UL low-voltage circuit-breaker installations.

Technical Specifications

Series SACE Tmax XT
ABB order code 1SDA104714R1
Alternate catalogue number KXT5WMP600-4
Product type Withdrawable moving-part conversion kit
Accessory type Circuit-breaker conversion kit
Compatible frame XT5
Rated uninterrupted current (Iu) 630 A
Number of poles 4
Version W – withdrawable
Configuration Loose / configurable
Reference standards IEC 60947-2, UL 489
Approvals IEC / UL
EAN / UPC 8015644068066
Net weight 0.302 kg

Frequently Asked Questions

What is the ABB 1SDA104714R1 used for?

The ABB 1SDA104714R1 is a conversion kit used to configure a compatible four-pole XT5 630 A circuit breaker as the moving part of a withdrawable installation.

Which ABB circuit-breaker frame is the 1SDA104714R1 designed for?

The kit is designed for compatible ABB SACE Tmax XT5 circuit breakers in the 630 A frame configuration.

How many poles does the ABB 1SDA104714R1 support?

The conversion kit is designed for a four-pole XT5 circuit breaker.

What does W MP mean in the ABB product description?

W MP identifies a kit for configuring the moving part of a withdrawable circuit-breaker execution.

Which standards apply to the ABB 1SDA104714R1?

ABB specifies the kit for IEC and UL applications, with reference standards including IEC 60947-2 and UL 489.

Trusted ABB Circuit Breaker Accessories