1SDA101966R1 ABB EXT CT N XT5 250 A Ekip Dip External Neutral Current Sensor

1SDA101966R1 ABB EXT CT N XT5 250 A Ekip Dip External Neutral Current Sensor

ABB 1SDA101966R1 is a 250 A external neutral current sensor designed for compatible SACE Tmax XT5 circuit breakers with Ekip Dip protection in IEC and UL applications.

SKU: 1SDA101966R1MPN: 1SDA101966R1
Price
List Price £192.09 ex VAT
Your Price (ex VAT) Save 25%
£144.07 25% OFF
You save £48.02 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £144.07
Trade pricing is personalised to your account

Manufacturer Lead Time

£144.07

Why Choose the ABB EXT CT N XT5 250 A Ekip Dip External Neutral Current Sensor?

The ABB EXT CT N XT5 250 A Ekip Dip, order code 1SDA101966R1, is an external neutral current sensor designed for use with compatible ABB SACE Tmax XT5 circuit breakers equipped with Ekip Dip protection. Rated for 250 A, it enables the protection system to monitor current flowing through an external neutral conductor as part of a correctly configured low-voltage distribution system.

Designed as an ABB Tmax XT accessory, the sensor extends current measurement to the neutral conductor where the neutral is installed externally to the circuit breaker. This allows the associated Ekip Dip protection system to incorporate neutral-current information into the overall protection arrangement while maintaining compatibility with the XT5 platform.

The 1SDA101966R1 is specified for IEC and UL applications and is associated with the 250 A XT5 Ekip Dip configuration. ABB identifies the accessory as a current sensor for external neutral and lists IEC 60947-2 and UL 489 as its reference standards, making it suitable for compatible industrial power-distribution installations requiring recognised IEC or UL configurations.

Key Advantages

  • Genuine ABB external neutral current sensor for compatible Tmax XT5 systems.
  • Designed for 250 A Ekip Dip applications.
  • Provides current sensing for an external neutral conductor.
  • Designed to integrate with the ABB SACE Tmax XT5 circuit-breaker platform.
  • Specified for both IEC and UL applications.
  • Supports coordinated current monitoring within industrial low-voltage distribution systems.
  • ABB-engineered accessory for dependable integration with compatible protection equipment.

Key Features

  • ABB SACE Tmax XT accessory.
  • External neutral current sensor configuration.
  • 250 A current rating.
  • Designed for compatible XT5 circuit breakers.
  • Compatibility with Ekip Dip protection configurations.
  • Suitable for IEC/UL applications.
  • Reference standards include IEC 60947-2 and UL 489.
  • Purpose-designed for monitoring current in an external neutral conductor.

Reliable External Neutral Current Monitoring

In electrical distribution systems where the neutral conductor is external to the circuit breaker, an appropriate external neutral sensor allows the protection system to measure neutral current alongside the phase conductors. This information supports the correct operation and coordination of compatible electronic protection functions within the installation.

The ABB 1SDA101966R1 is specifically designed for this role within compatible XT5 250 A Ekip Dip installations. As a dedicated ABB accessory, it provides a practical way to incorporate an external neutral conductor into the current-sensing arrangement while retaining compatibility with the Tmax XT protection platform.

Typical Applications

  • ABB SACE Tmax XT5 circuit-breaker installations.
  • External neutral current monitoring.
  • Industrial low-voltage distribution boards.
  • Electrical switchboards and control panels.
  • Commercial and industrial power-distribution systems.
  • IEC-compliant circuit-breaker installations.
  • UL-compliant power-distribution applications.

Technical Specifications

Series SACE Tmax XT
ABB order code 1SDA101966R1
Product type External neutral current sensor
Compatible breaker frame XT5
Rated current 250 A
Protection compatibility Ekip Dip
Application External neutral current sensing
Standards IEC 60947-2, UL 489
Compliance IEC / UL
EAN 8056221020107
Country of origin Italy
Weight 1.3 kg

Frequently Asked Questions

What is the ABB 1SDA101966R1 used for?

The ABB 1SDA101966R1 is an external neutral current sensor used to measure current in an external neutral conductor in compatible ABB XT5 Ekip Dip circuit-breaker installations.

What current rating does the ABB 1SDA101966R1 have?

The external neutral current sensor is specified for a 250 A XT5 Ekip Dip configuration.

Which ABB circuit-breaker family is this sensor designed for?

It is designed for compatible ABB SACE Tmax XT5 circuit breakers using Ekip Dip protection.

Does the ABB 1SDA101966R1 support IEC and UL applications?

Yes. ABB specifies the accessory for IEC/UL applications, with IEC 60947-2 and UL 489 listed as reference standards.

Why is an external neutral current sensor used?

An external neutral current sensor allows a compatible protection system to measure current flowing through a neutral conductor located outside the circuit breaker, incorporating neutral-current information into the protection arrangement.

Trusted ABB Protection Accessories

ABB SACE Tmax XT accessories are engineered to extend the functionality of compatible circuit breakers, providing coordinated sensing, protection and integration for demanding industrial and commercial low-voltage distribution systems.