1SDA100810R1 ABB Ekip G Dip LS/I In=800 XT6 3-Pole Generator Protection Trip Unit

1SDA100810R1 ABB Ekip G Dip LS/I In=800 XT6 3-Pole Generator Protection Trip Unit

ABB 1SDA100810R1 is a three-pole Ekip G Dip LS/I electronic generator-protection trip unit rated at 800 A for compatible Tmax XT6 circuit breakers, providing long-time overload and short-circuit protection for low-voltage generator applications.

SKU: 1SDA100810R1MPN: 1SDA100810R1
Price
List Price £1,170.35 ex VAT
Your Price (ex VAT) Save 25%
£877.76 25% OFF
You save £292.59 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £877.76
Trade pricing is personalised to your account

Manufacturer Lead Time

£877.76

Why Choose the ABB Ekip G Dip LS/I In=800 XT6 3p Trip Unit 1SDA100810R1?

The ABB Ekip G Dip LS/I In=800 XT6 3p 1SDA100810R1 is a three-pole electronic generator-protection trip unit designed for compatible ABB SACE Tmax XT6 moulded case circuit breakers. Rated at 800 A, it is engineered specifically for generator protection applications where dependable overload and short-circuit protection is required within low-voltage power generation and distribution systems.

The Ekip G Dip LS/I combines long-time overload protection (L) with short-time / instantaneous short-circuit protection (S/I). Its generator-specific protection characteristics are designed to accommodate the particular fault-current behaviour of generating sets while providing effective protection for the generator and associated electrical distribution network.

Designed specifically for the ABB Tmax XT6 three-pole platform, the 1SDA100810R1 is supplied as a separate electronic protection release and must be combined with a compatible three-pole XT6 breaking part to create a complete circuit breaker. Its electronic protection technology and dedicated generator application make it suitable for generator incomers, standby power systems and distributed generation installations.

Key Advantages

  • Genuine ABB SACE Tmax XT6 Ekip G Dip electronic trip unit.
  • Specifically designed for generator protection.
  • 800 A rated current for high-current generator circuits.
  • Three-pole configuration for compatible three-phase XT6 circuit breakers.
  • LS/I protection functions for overload and short-circuit protection.
  • Long-time protection (L) protects against sustained overload conditions.
  • Short-time / instantaneous protection (S/I) provides protection against short-circuit faults.
  • Electronic protection characteristics designed for generator applications.
  • Modular construction allows the release to be combined with a compatible ABB XT6 breaking part.
  • Suitable for standby, prime-power and distributed generation systems when correctly engineered into the complete protection scheme.

Key Features

  • ABB SACE Tmax XT6 series.
  • Ekip G Dip electronic generator-protection technology.
  • LS/I protection functions.
  • 800 A rated current (In).
  • Three-pole configuration.
  • Long-time overload protection (L).
  • Short-time / instantaneous short-circuit protection (S/I).
  • Generator protection application.
  • AC current type.
  • Electronic release type.
  • Loose or configurable installation format.
  • Designed for compatible ABB SACE Tmax XT6 circuit breakers.
  • Suitable for power circuit breaker applications.
  • Designed in accordance with IEC 60947-2.

Electronic LS/I Protection for Generator Circuits

Generator circuits present different protection requirements from conventional utility-fed distribution systems because generator short-circuit currents can be lower and can decay rapidly after a fault occurs. The ABB Ekip G Dip range is specifically intended for generator applications, providing protection characteristics designed to safeguard generating equipment while maintaining appropriate coordination with the wider electrical installation.

The 1SDA100810R1 combines an 800 A rated current with LS/I electronic protection in a three-pole format for the XT6 platform. Long-time protection addresses sustained overloads, while the S/I functionality protects against short-circuit conditions. When combined with the appropriate ABB XT6 breaking part, the release forms part of a configurable circuit breaker solution for generator incomers and high-current generating systems.

Typical Applications

  • Generator circuit protection.
  • Diesel generator sets.
  • Standby and emergency power systems.
  • Prime-power generating installations.
  • Generator incomer circuit breakers.
  • ABB Tmax XT6 generator circuit breaker assemblies.
  • Industrial generating plants.
  • Critical-power and infrastructure installations.
  • Distributed generation systems.
  • Three-phase generator distribution systems.
  • Commercial and industrial standby power installations.
  • Applications requiring dedicated electronic overload and short-circuit generator protection.

Technical Specifications

Series SACE Tmax XT
Compatible frame XT6
ABB order code 1SDA100810R1
EAN / GTIN 8056221008648
Product type Electronic circuit breaker trip unit / protection release
Trip-unit technology Ekip G Dip electronic
Protection functions LS/I
Protection application Generator protection
Rated current (In) 800 A
Number of poles 3
Current type AC
Long-time protection L
Short-time / instantaneous protection S/I
Release type Electronic (EL)
Configuration type Loose or configurable
Compatible circuit breaker platform ABB SACE Tmax XT6
Suitable for power circuit breakers Yes
Suitable for switch-disconnectors No
Standard IEC 60947-2
Product net weight 1.3 kg
Package dimensions (W × H × D) 120 × 160 × 190 mm
Package gross weight 1.4 kg
Customs tariff number 85389099

Frequently Asked Questions

What is the ABB Ekip G Dip LS/I 1SDA100810R1?

The ABB 1SDA100810R1 is a three-pole Ekip G Dip LS/I electronic generator-protection trip unit rated at 800 A for use with compatible ABB SACE Tmax XT6 moulded case circuit breaker breaking parts.

What is the ABB Ekip G Dip 1SDA100810R1 designed to protect?

The Ekip G Dip is specifically designed for generator protection, providing electronic protection for generating sets and their associated low-voltage electrical circuits when installed in a compatible ABB Tmax XT6 circuit breaker.

What protection functions does the ABB Ekip G Dip LS/I provide?

The release provides long-time overload protection (L) together with short-time / instantaneous short-circuit protection (S/I) for generator circuit applications.

What is the rated current of the ABB 1SDA100810R1?

The ABB Ekip G Dip LS/I 1SDA100810R1 has a rated current of 800 A and a three-pole configuration for the ABB SACE Tmax XT6 platform.

Can the ABB 1SDA100810R1 be used on its own?

No. The 1SDA100810R1 is a separate electronic protection trip unit and must be combined with a compatible three-pole ABB Tmax XT6 breaking part to create a complete generator-protection circuit breaker.

Trusted Generator Protection from ABB

ABB SACE Tmax XT Ekip G protection units provide dedicated electronic protection for generator applications, combining overload and short-circuit protection with the modular flexibility of the Tmax XT circuit breaker platform for dependable low-voltage generation systems.