1SDA100702R1 ABB Ekip G Dip LS/I 630 A XT5 4-Pole Generator Protection Trip Unit

1SDA100702R1 ABB Ekip G Dip LS/I 630 A XT5 4-Pole Generator Protection Trip Unit

ABB 1SDA100702R1 Ekip G Dip LS/I electronic generator protection trip unit rated at 630 A for 4-pole AC ABB Tmax XT5 moulded-case circuit breaker applications.

SKU: 1SDA100702R1MPN: 1SDA100702R1
Price
List Price £756.97 ex VAT
Your Price (ex VAT) Save 25%
£567.73 25% OFF
You save £189.24 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £567.73
Trade pricing is personalised to your account

Manufacturer Lead Time

£567.73

Why Choose the ABB 1SDA100702R1 Ekip G Dip LS/I Trip Unit?

The ABB 1SDA100702R1 is an Ekip G Dip LS/I electronic trip unit designed specifically for generator protection with compatible ABB Tmax XT5 moulded-case circuit breakers. Rated at 630 A and configured for 4-pole AC applications, it provides dedicated electronic protection for generators and generator-fed low-voltage electrical distribution systems.

As part of the ABB SACE Tmax XT range, the Ekip G Dip platform is engineered around the particular protection requirements of generators. Its LS/I functionality provides long-time overload protection together with short-circuit protection, while electronic configuration allows the protection characteristics to be coordinated with generator operating and fault-current behaviour.

With a rated current of 630 A, the 1SDA100702R1 is intended for a compatible 4-pole ABB Tmax XT5 circuit breaker. Its generator-focused protection characteristics make it suitable for industrial generating systems, standby power installations and other applications where dependable protection of generators and associated distribution equipment is required.

Key Advantages

  • Dedicated Ekip G Dip electronic trip unit for generator protection.
  • 630 A rated current for high-current generator applications.
  • 4-pole AC configuration suitable for three-phase generator systems incorporating a neutral conductor.
  • LS/I protection functionality designed around generator protection requirements.
  • Electronic protection provides configurable characteristics for effective system coordination.
  • Designed specifically for integration with compatible ABB Tmax XT5 moulded-case circuit breakers.

Key Features

  • ABB Ekip G Dip LS/I electronic release.
  • 630 A rated current (In).
  • 4-pole configuration.
  • AC current application.
  • Designed for compatible ABB Tmax XT5 moulded-case circuit breakers.
  • Dedicated generator protection application.
  • Long-time (L) overload protection.
  • Short-circuit (S/I) protection functionality.
  • Electronic DIP-style protection configuration.
  • Loose or configurable installation format.
  • Designed in accordance with IEC 60947-2.

Dedicated Electronic Protection for Generators

Generator protection differs from conventional distribution protection because generator fault currents and overload characteristics can differ significantly from those of utility-fed systems. The ABB Ekip G range is specifically designed for generator applications, helping provide appropriate protection while accommodating the operating characteristics of generating equipment.

The Ekip G Dip LS/I release combines electronic overload and short-circuit protection in a configuration designed for generator circuits. When paired with the appropriate Tmax XT5 breaking unit, the 1SDA100702R1 provides a dependable protection solution for generator feeders, standby generating systems and industrial power generation installations.

Typical Applications

  • Industrial generator protection systems.
  • Standby and emergency power generators.
  • Four-pole three-phase generator circuits.
  • Generator-fed low-voltage switchboards.
  • Commercial and infrastructure standby power systems.
  • Industrial plants with on-site generation.
  • ABB Tmax XT5 circuit breaker installations requiring dedicated generator protection.

Technical Specifications

Series SACE Tmax XT
Product group T-Max XT 250 Range
Model / order code 1SDA100702R1
Product type Electronic generator protection trip unit
Release Ekip G Dip LS/I
Release type EL electronic release
Compatible frame Tmax XT5
Rated current (In) 630 A
Number of poles 4
Current type AC
Protection functions LS/I
Application Generator protection
Configuration type Loose or configurable
Standard IEC 60947-2
GTIN / EAN 8056221007788
Product net weight 1.85 kg
Minimum order quantity 1 piece

Frequently Asked Questions

What is the ABB 1SDA100702R1 used for?

The ABB 1SDA100702R1 is an Ekip G Dip LS/I electronic trip unit designed specifically for generator protection when used with a compatible ABB Tmax XT5 moulded-case circuit breaker.

What is the rated current of the 1SDA100702R1?

The trip unit has a rated current of 630 A.

What does Ekip G mean?

The Ekip G designation identifies an ABB electronic trip unit intended for generator protection applications, with protection characteristics designed around the operating requirements of generating equipment.

Which ABB circuit breaker is the 1SDA100702R1 designed for?

The 1SDA100702R1 is designed for use with a compatible 4-pole ABB Tmax XT5 moulded-case circuit breaker.

Is the ABB 1SDA100702R1 suitable for generator protection?

Yes. The Ekip G Dip LS/I is specifically intended for generator protection, making the 1SDA100702R1 suitable for standby generators, industrial generating systems and generator-fed low-voltage distribution installations.

Trusted ABB Generator Protection Technology

ABB Ekip G electronic releases and SACE Tmax XT circuit breakers provide dedicated protection for generators and generator-fed electrical systems, combining electronic protection technology with the flexibility required for industrial, commercial and critical-power installations.