ABB 1SDA100697R1 TMG 500-2500 thermomagnetic generator-protection trip unit for Tmax XT5 circuit breakers, rated at 500 A with four poles, a 100% rated neutral and adjustable 1250–2500 A instantaneous magnetic protection.
£513.66
The ABB TMG 500-2500 XT5 4p In=100%In is a robust thermomagnetic generator-protection trip unit designed for use with compatible ABB Tmax XT5 moulded-case circuit breakers. Identified by ABB order code 1SDA100697R1, this four-pole release combines thermal overload protection with adjustable instantaneous magnetic short-circuit protection for dependable protection of generators and associated low-voltage distribution circuits.
As part of the ABB Tmax XT5 protection system, the TMG release is specifically designed for generator applications. Its thermomagnetic operating principle provides reliable protection against sustained overloads and severe short-circuit faults, while its adjustable magnetic threshold supports effective coordination with generator characteristics and the wider electrical installation.
With a rated current of 500 A, a four-pole configuration and a neutral rated at 100% of phase current, the TMG 500-2500 provides full neutral protection for suitable three-phase four-wire systems. Its instantaneous magnetic short-circuit protection is adjustable from 1250–2500 A, making it well suited to generator installations requiring a lower magnetic trip threshold than conventional distribution protection.
Generator circuits require protection characteristics that account for their particular short-circuit behaviour while still providing dependable protection against sustained overloads. The ABB TMG range addresses these requirements through combined thermal overload and adjustable instantaneous magnetic protection specifically intended for generator applications.
The four-pole design of the 1SDA100697R1 enables protection of the three phase conductors together with the neutral conductor. With the neutral rated at 100% of phase current and an adjustable instantaneous magnetic threshold of 1250–2500 A, the unit provides a practical protection solution for compatible XT5 generator circuit-breaker assemblies.
| Series | Tmax XT5 |
|---|---|
| ABB order code | 1SDA100697R1 |
| Product type | Thermomagnetic trip unit |
| Protection application | Generator protection |
| Trip unit type | TMG |
| Rated current | 500 A |
| Instantaneous magnetic protection | 1250–2500 A |
| Number of poles | 4 |
| Neutral rating | 100% In |
| Compatible breaker frame | ABB Tmax XT5 |
| Protection technology | Thermomagnetic |
| EAN / GTIN | 8056221007733 |
The ABB 1SDA100697R1 is a TMG thermomagnetic trip unit designed for generator protection with compatible ABB Tmax XT5 moulded-case circuit breakers.
This TMG trip unit has a rated current of 500 A.
The TMG 500-2500 provides adjustable instantaneous magnetic short-circuit protection from 1250–2500 A.
The 1SDA100697R1 is a four-pole trip unit with the neutral rated at 100% of phase current.
The TMG 500-2500 1SDA100697R1 is designed for compatible ABB Tmax XT5 moulded-case circuit breakers.
ABB Tmax XT circuit breakers and TMG thermomagnetic releases provide dependable generator and low-voltage distribution protection, combining thermal overload protection with magnetic short-circuit protection for demanding industrial, commercial and infrastructure applications.