ABB 1SDA100696R1 TMG 400-2000 thermomagnetic generator-protection trip unit for Tmax XT5 circuit breakers, rated at 400 A with four poles and a 100% rated neutral.
£497.22
The ABB TMG 400-2000 XT5 4p In=100%In is a thermomagnetic generator-protection trip unit designed for use with compatible ABB Tmax XT5 moulded-case circuit breakers. Identified by ABB order code 1SDA100696R1, it combines thermal overload protection with magnetic short-circuit protection for dependable protection of generators and low-voltage electrical distribution systems.
As part of the ABB Tmax XT5 protection system, this TMG release is specifically intended for generator-protection applications. Its thermomagnetic operating principle provides reliable protection without requiring a separate electronic trip-unit power supply, while the adjustable magnetic protection range allows the protection characteristics to be coordinated with the installation.
The TMG 400-2000 is rated at 400 A and is configured for four-pole operation with the neutral rated at 100% of phase current. Its instantaneous magnetic protection setting extends up to 2000 A, making the unit suitable for compatible XT5 circuit-breaker assemblies protecting generators and associated distribution circuits.
Generator circuits require protection against both sustained overloads and high-current short-circuit faults while accommodating the operating characteristics of generating equipment. The ABB TMG trip-unit range is designed specifically for this role, combining thermal and magnetic protection functions within the Tmax XT platform.
The four-pole design of the 1SDA100696R1 enables protection of all three phase conductors together with the neutral conductor. With the neutral rated at 100% of the phase current, the unit is well suited to installations where full neutral protection is required alongside dependable generator and distribution-circuit protection.
| Series | Tmax XT5 |
|---|---|
| ABB order code | 1SDA100696R1 |
| Product type | Thermomagnetic trip unit |
| Protection application | Generator protection |
| Trip unit type | TMG |
| Rated current | 400 A |
| Magnetic protection range | up to 2000 A |
| Number of poles | 4 |
| Neutral rating | 100% In |
| Compatible breaker frame | ABB Tmax XT5 |
| Protection technology | Thermomagnetic |
| EAN | 8056221007726 |
The ABB 1SDA100696R1 is a TMG thermomagnetic trip unit designed for generator protection with compatible ABB Tmax XT5 moulded-case circuit breakers.
This TMG trip unit has a rated current of 400 A.
TMG technology provides thermal overload and magnetic short-circuit protection, making it suitable for protecting generator circuits against damaging overcurrent conditions.
The 1SDA100696R1 is a four-pole trip unit with the neutral rated at 100% of the phase current.
The TMG 400-2000 1SDA100696R1 is designed for compatible ABB Tmax XT5 moulded-case circuit breakers.
ABB Tmax XT circuit breakers and TMG thermomagnetic releases provide dependable protection for generators and low-voltage distribution systems, combining robust circuit protection with the flexibility required by modern industrial and commercial electrical installations.