1SDA100695R1 ABB TMG 320-1600 XT5 4-Pole Generator Protection Release

1SDA100695R1 ABB TMG 320-1600 XT5 4-Pole Generator Protection Release

ABB 1SDA100695R1 is a 320 A four-pole TMG thermomagnetic generator protection release for Tmax XT5 circuit breakers with an 800–1600 A magnetic protection range and a fully rated neutral.

SKU: 1SDA100695R1MPN: 1SDA100695R1
Price
List Price £662.96 ex VAT
Your Price (ex VAT) Save 25%
£497.22 25% OFF
You save £165.74 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £497.22
Trade pricing is personalised to your account

Manufacturer Lead Time

£497.22

Why Choose the ABB TMG 320-1600 XT5 4-Pole Generator Protection Release?

The ABB TMG 320-1600 XT5 4p InN=100%In is a thermomagnetic protection release designed for ABB Tmax XT5 moulded-case circuit breakers used in generator protection applications. Identified by ABB order code 1SDA100695R1, this four-pole release combines thermal overload protection with magnetic short-circuit protection for dependable low-voltage generator circuits.

As part of the ABB Tmax XT5 circuit-breaker platform, the TMG release is specifically intended for generator protection. It has a rated current of 320 A and an instantaneous magnetic protection range of 800–1600 A, providing a magnetic threshold suited to the particular protection requirements associated with generating equipment.

The four-pole configuration incorporates a fully rated neutral, with InN = 100% In, allowing the neutral pole to carry and be protected at the same rated current as the phase poles. The release is designed for use with a compatible ABB Tmax XT5 breaking part to create a complete generator-protection circuit-breaker assembly.

Key Advantages

  • Purpose-designed TMG thermomagnetic release for generator protection.
  • 320 A rated current for compatible ABB Tmax XT5 assemblies.
  • 800–1600 A magnetic protection range for short-circuit protection.
  • Four-pole configuration for three-phase systems with switched neutral.
  • Fully rated neutral at 100% In.
  • Integrates with the modular ABB Tmax XT5 circuit-breaker platform.

Key Features

  • ABB TMG generator-protection thermomagnetic release.
  • Designed specifically for the ABB Tmax XT5 breaker frame.
  • 320 A rated current.
  • 800–1600 A instantaneous magnetic protection range.
  • 4-pole configuration.
  • Neutral rating: InN = 100% In.
  • Thermal protection against sustained overload conditions.
  • Magnetic protection against high short-circuit currents.

Reliable Thermomagnetic Protection for Generators

Generator circuits require protection characteristics that account for the operating behaviour and available short-circuit current of generating equipment. The ABB TMG release combines thermal overload protection with magnetic short-circuit protection, helping protect generators, conductors and associated distribution equipment against damaging overcurrent conditions.

The TMG 320-1600 release is engineered for the ABB Tmax XT5 platform and provides a magnetic protection range of 800–1600 A. Its four-pole design with a fully rated neutral makes it suitable for generator distribution systems where protection and switching of all phase conductors and the neutral are required.

Typical Applications

  • Low-voltage generator protection systems.
  • Standby and emergency generating sets.
  • Industrial generator distribution switchboards.
  • Commercial building standby power systems.
  • Generator-fed main and sub-main distribution circuits.
  • Four-pole generator circuits requiring a fully rated neutral.

Technical Specifications

Series Tmax XT5
ABB order code 1SDA100695R1
EAN / GTIN 8056221007719
Product type Thermomagnetic generator protection release
Trip unit type TMG
Rated current 320 A
Instantaneous magnetic protection range 800–1600 A
Number of poles 4
Neutral rating 100% In
Protection technology Thermomagnetic
Application Generator protection
Compatible breaker frame ABB Tmax XT5
Product net weight 1.214 kg

Frequently Asked Questions

What is the ABB 1SDA100695R1 used for?

The ABB 1SDA100695R1 is a TMG thermomagnetic protection release designed for generator protection using compatible ABB Tmax XT5 moulded-case circuit-breaker assemblies.

What is the rated current of the ABB TMG 320-1600 XT5 release?

The release has a rated current of 320 A.

What is the magnetic protection range of the 1SDA100695R1?

The instantaneous magnetic protection range is 800–1600 A.

What does TMG mean on this ABB Tmax XT5 release?

TMG identifies an ABB thermomagnetic release intended for generator protection, combining thermal overload and magnetic short-circuit protection.

Is the neutral fully rated on the ABB 1SDA100695R1?

Yes. This four-pole version has InN = 100% In, meaning the neutral is rated at 100% of the phase rated current.

Is the ABB 1SDA100695R1 a complete circuit breaker?

No. The 1SDA100695R1 is the TMG protection release and is designed to be combined with a compatible ABB Tmax XT5 breaking part to form the required circuit-breaker assembly.

Trusted by Electrical Professionals Worldwide

ABB Tmax XT circuit protection products are widely used by panel builders, generator-system integrators and electrical engineers to provide dependable overcurrent protection for industrial, commercial and infrastructure power distribution systems.