1SDA100340R1 ABB Ekip Dip LIG 63 A XT4 4-Pole Trip Unit

1SDA100340R1 ABB Ekip Dip LIG 63 A XT4 4-Pole Trip Unit

ABB 1SDA100340R1 Ekip Dip LIG 63 A electronic trip unit for compatible 4-pole SACE Tmax XT4 circuit breakers, providing configurable long-time overload, instantaneous short-circuit and earth-fault protection for low-voltage power distribution.

SKU: 1SDA100340R1MPN: 1SDA100340R1
Price
List Price £1,481.70 ex VAT
Your Price (ex VAT) Save 25%
£1,111.28 25% OFF
You save £370.43 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,111.28
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,111.28

Why Choose the ABB 1SDA100340R1 Ekip Dip LIG 63 A XT4 4-Pole Trip Unit?

The ABB 1SDA100340R1 is an Ekip Dip LIG electronic trip unit designed for compatible SACE Tmax XT4 moulded-case circuit breakers. Rated at 63 A and configured for 4-pole applications, it provides configurable electronic protection for low-voltage power distribution systems.

As part of the ABB SACE Tmax XT protection platform, the Ekip Dip LIG release provides LIG protection, comprising long-time overload, instantaneous short-circuit and earth-fault functions. The electronic release enables the overload threshold to be adjusted over the 0.4–1 × In range, providing flexibility when coordinating protection with cables and connected distribution equipment.

The 1SDA100340R1 is specifically designed for XT4 4-pole circuit-breaker configurations and has a nominal current of 63 A. It is a separate electronic protection release rather than a complete moulded-case circuit breaker and must be combined with a compatible four-pole XT4 breaking part selected according to the required short-circuit performance and installation requirements.

Key Advantages

  • Genuine ABB Ekip Dip LIG electronic trip unit for SACE Tmax XT4 circuit breakers.
  • 63 A rated current for compatible low-voltage power-distribution applications.
  • LIG protection combines overload, instantaneous short-circuit and earth-fault protection.
  • Designed specifically for compatible 4-pole ABB SACE Tmax XT4 circuit breakers.
  • Long-time overload protection adjustable from 0.4–1 × In.
  • Corresponding long-time current setting range of approximately 25.2–63 A.
  • Electronic protection provides accurate and repeatable operation for modern distribution systems.
  • Modular design allows combination with an appropriate four-pole XT4 breaking part.

Key Features

  • ABB Ekip Dip LIG electronic trip unit.
  • 63 A rated current (In).
  • Designed for SACE Tmax XT4 circuit breakers.
  • 4-pole configuration.
  • Long-time overload protection (L).
  • Instantaneous short-circuit protection (I).
  • Earth-fault protection (G).
  • Long-time overload adjustment from 0.4–1 × In.
  • Long-time current setting range of approximately 25.2–63 A.
  • Electronic protection technology.
  • Designed for power-distribution applications.
  • Separate trip-unit format for modular XT4 assembly.
  • Suitable for compatible four-pole XT4 breaking parts.
  • Part of ABB's flexible SACE Tmax XT protection ecosystem.

Configurable LIG Protection for SACE Tmax XT4

The ABB Ekip Dip LIG platform combines three important electronic protection functions within a compact release. Long-time protection responds to sustained overload conditions, instantaneous protection provides rapid interruption during severe short circuits, and the earth-fault function adds dedicated protection against ground-fault currents within the electrical distribution system.

For the 63 A 1SDA100340R1, the long-time overload setting is adjustable from 0.4–1 × In, corresponding to approximately 25.2–63 A. As a separate four-pole electronic release, it can be paired with an appropriate SACE Tmax XT4 four-pole breaking part, allowing the short-circuit interruption performance and electronic protection characteristics of the complete circuit breaker to be selected for the application.

Typical Applications

  • ABB SACE Tmax XT4 circuit-breaker assemblies.
  • Industrial low-voltage power distribution.
  • Commercial building electrical distribution.
  • Main and sub-distribution switchboards.
  • Manufacturing and process facilities.
  • Four-pole feeder and cable protection.
  • Generator and electrical installation protection.
  • Applications requiring electronic earth-fault protection.

Technical Specifications

Series SACE Tmax XT / Ekip Dip
Product range T-Max XT 250 Range
Order code 1SDA100340R1
Product type Electronic circuit-breaker trip unit / protection release
Compatible circuit-breaker frame SACE Tmax XT4
Trip-unit rated current (In) 63 A
Number of poles 4
Protection functions L, I and G
Long-time overload protection L
Instantaneous short-circuit protection I
Earth-fault protection G
Long-time adjustment range 0.4–1 × In
Long-time current setting range approximately 25.2–63 A
Release technology Electronic
Circuit-breaker application Power distribution
Suitable for circuit breakers Yes
Suitable for overload protection Yes
Unit weight 1 kg
GTIN / EAN 8056221004176
Customs tariff number 85389099

Frequently Asked Questions

What is the ABB 1SDA100340R1?

The ABB 1SDA100340R1 is an Ekip Dip LIG electronic trip unit rated at 63 A for compatible 4-pole SACE Tmax XT4 moulded-case circuit breakers.

What protection functions does the ABB 1SDA100340R1 provide?

The trip unit provides LIG protection: long-time overload protection (L), instantaneous short-circuit protection (I) and earth-fault protection (G).

What is the adjustable overload range of the ABB 1SDA100340R1?

The long-time overload setting is adjustable from 0.4–1 × In, corresponding to approximately 25.2–63 A for this 63 A Ekip Dip LIG release.

Does the ABB 1SDA100340R1 provide earth-fault protection?

Yes. The G protection function provides electronic earth-fault protection in addition to long-time overload and instantaneous short-circuit protection.

Is the ABB 1SDA100340R1 a complete circuit breaker?

No. The 1SDA100340R1 is a 4-pole electronic trip unit / protection release designed for a compatible SACE Tmax XT4 circuit breaker and must be combined with an appropriate four-pole XT4 breaking part to form a complete circuit-breaker assembly.

Reliable ABB Electronic Protection for Power Distribution

ABB Ekip electronic trip units combine configurable microprocessor-based protection with the modular SACE Tmax XT platform to support dependable protection of modern industrial, commercial and infrastructure power distribution systems.