1SDA100167R1 ABB Ekip Dip LIG 25A XT2 4-Pole Trip Unit

1SDA100167R1 ABB Ekip Dip LIG 25A XT2 4-Pole Trip Unit

ABB 1SDA100167R1 is a 25 A four-pole Ekip Dip LIG solid-state electronic trip unit for SACE Tmax XT2 circuit breakers, providing long-time, instantaneous and ground-fault protection for low-voltage AC power distribution.

SKU: 1SDA100167R1MPN: 1SDA100167R1
Price
List Price £1,340.68 ex VAT
Your Price (ex VAT) Save 25%
£1,005.51 25% OFF
You save £335.17 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,005.51
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,005.51

Why Choose the ABB Ekip Dip LIG 25A XT2 4-Pole Trip Unit?

The ABB Ekip Dip LIG In=25A XT2 4p, order code 1SDA100167R1, is a solid-state electronic trip unit designed for ABB SACE Tmax XT2 moulded case circuit breakers. Rated at 25 A, this four-pole electronic release provides configurable protection for low-voltage AC power distribution applications.

The Ekip Dip LIG release provides L, I and G protection functions, combining long-time overload, instantaneous short-circuit and ground-fault protection. The overload setting is adjustable across 0.4–1 × In, while short-circuit protection can be adjusted across 1–10 × In, supporting effective coordination with the requirements of the protected circuit.

Designed specifically for the ABB SACE Tmax XT2 platform, the 1SDA100167R1 has a 25 A rated current and 4-pole configuration. It is supplied as a loose or configurable electronic release and is intended to be combined with a compatible four-pole XT2 breaking unit to form a complete moulded case circuit breaker.

Key Advantages

  • Genuine ABB Ekip Dip electronic trip unit for SACE Tmax XT2.
  • 25 A rated current for lower-current distribution circuits.
  • LIG protection functions covering overload, instantaneous short-circuit and ground-fault conditions.
  • Adjustable overload protection from 0.4–1 × In.
  • Adjustable short-circuit protection from 1–10 × In.
  • 4-pole configuration for four-pole AC distribution systems.
  • Compact solid-state protection engineered specifically for the ABB SACE Tmax XT2 platform.

Key Features

  • ABB Ekip Dip LIG series.
  • 25 A rated current (In).
  • 4-pole electronic release.
  • LIG protection functions.
  • Long-time overload protection.
  • Instantaneous short-circuit protection.
  • Ground-fault protection.
  • Long-time setting range of 0.4–1 × In.
  • Short-circuit setting range of 1–10 × In.
  • EL solid-state electronic release technology.
  • Designed for AC power distribution.
  • Loose or configurable installation format.
  • Compatible with the ABB SACE Tmax XT2 platform.

Reliable LIG Electronic Protection for Tmax XT2

Electronic trip units monitor current through a circuit breaker and initiate tripping when configured protection thresholds are exceeded. The ABB Ekip Dip LIG combines long-time overload, instantaneous short-circuit and ground-fault functions, providing comprehensive electronic protection against common fault conditions in low-voltage distribution systems.

The Ekip Dip platform provides adjustable protection in a compact format engineered for the Tmax XT range. When the 1SDA100167R1 is combined with a compatible four-pole XT2 breaking unit, it forms part of a complete circuit-breaker assembly suitable for protecting feeders, distribution circuits and electrical equipment.

Typical Applications

  • ABB SACE Tmax XT2 circuit-breaker assemblies.
  • Low-voltage power distribution boards.
  • Industrial electrical switchboards.
  • Commercial power distribution systems.
  • Four-pole feeder protection.
  • Circuits requiring ground-fault protection.
  • Machinery and equipment distribution circuits.
  • OEM control and power distribution panels.

Technical Specifications

Series Ekip Dip / SACE Tmax XT2
ABB order code 1SDA100167R1
Product group T-Max XT 250 Range
Product type Solid-state electronic circuit-breaker trip unit
Compatible breaker SACE Tmax XT2
Circuit-breaker application Power distribution
Rated current (In) 25 A
Trip unit Ekip Dip LIG
Release type EL electronic release
Protection functions LIG
Long-time protection L
Overload adjustment 0.4–1 × In
Instantaneous protection I
Short-circuit adjustment 1–10 × In
Ground-fault protection G
Number of poles 4
Current type AC
Configuration type Loose or configurable
Standard IEC 60947-2
Product net weight 1 kg
Package dimensions (D × H × W) 150 × 100 × 110 mm
Package gross weight 1.1 kg
EAN / GTIN 8056221002219

Frequently Asked Questions

What is the ABB 1SDA100167R1?

The 1SDA100167R1 is a 25 A Ekip Dip LIG solid-state electronic trip unit designed for four-pole ABB SACE Tmax XT2 circuit breakers.

What protection functions does the Ekip Dip LIG provide?

The unit provides LIG protection, comprising long-time overload, instantaneous short-circuit and ground-fault protection.

What is the rated current of the ABB 1SDA100167R1?

The Ekip Dip LIG trip unit has a rated current of 25 A.

What protection adjustment ranges are available?

The Ekip Dip LIG provides an overload adjustment range of 0.4–1 × In and a short-circuit protection adjustment range of 1–10 × In.

Is the ABB 1SDA100167R1 a complete circuit breaker?

No. The 1SDA100167R1 is a 4-pole Ekip Dip electronic trip unit and must be combined with a compatible four-pole ABB SACE Tmax XT2 breaking unit to form a complete circuit breaker.

Trusted ABB Electronic Protection

ABB Ekip Dip electronic trip units provide adjustable solid-state protection for SACE Tmax XT circuit breakers, supporting dependable low-voltage power distribution in industrial, commercial and OEM installations.