Why Choose the ABB Ekip Touch LSIG In=160A XT2 3p?

The ABB 1SDA100107R1 Ekip Touch LSIG In=160A XT2 3p is an advanced electronic trip unit designed for ABB SACE Tmax XT2 moulded case circuit breakers, providing intelligent protection, monitoring and control for low voltage electrical distribution systems. As part of the ABB Tmax XT accessory and protection system, it delivers accurate LSIG protection functions for demanding industrial and commercial applications. :chatgpt-content-reference{index="0"}

The Ekip Touch LSIG unit provides adjustable long-time, short-time, instantaneous and ground fault protection, enabling improved coordination and selectivity within electrical networks. Its electronic design allows precise protection settings while supporting modern switchgear requirements and advanced circuit breaker functionality. :chatgpt-content-reference{index="1"}

With a 160 A rated current and compatibility with ABB Tmax XT2 three-pole circuit breakers, the ABB 1SDA100107R1 provides a flexible protection solution for energy distribution, cable protection and industrial electrical systems. :chatgpt-content-reference{index="2"}

Key Advantages

  • Advanced ABB Ekip Touch LSIG electronic protection unit for Tmax XT2 circuit breakers.
  • 160 A rated current suitable for industrial distribution applications.
  • Provides LSIG protection functions for improved system safety and coordination.
  • Digital interface enables simplified protection setting and monitoring.
  • Designed for integration with ABB Tmax XT2 moulded case circuit breakers.
  • Supports reliable protection of electrical distribution systems, cables and equipment.

Key Features

  • ABB Tmax XT series electronic trip unit.
  • Ekip Touch LSIG protection release.
  • 160 A rated current.
  • Three-pole XT2 configuration.
  • Solid-state electronic protection technology.
  • Long-time (L) protection.
  • Short-time (S) protection.
  • Instantaneous (I) protection.
  • Ground fault (G) protection.
  • Compatible with ABB SACE Tmax XT2 MCCBs.

Intelligent Protection for Low Voltage Distribution

Electronic trip units such as the ABB Ekip Touch LSIG provide accurate monitoring and protection by continuously analysing electrical conditions and applying configurable protection thresholds. This allows engineers to improve system coordination, reduce downtime and enhance operational safety.

The Ekip Touch platform forms part of ABB’s intelligent Tmax XT ecosystem, combining advanced protection technology with digital configuration and connectivity options for modern electrical installations. :chatgpt-content-reference{index="3"}

Typical Applications

  • Industrial electrical distribution systems.
  • Low voltage switchboards and panels.
  • Motor control centres.
  • Commercial electrical infrastructure.
  • Machine and automation systems.
  • OEM equipment requiring advanced circuit protection.

Technical Specifications

Order code 1SDA100107R1
Series Tmax XT
Product type Electronic trip unit
Suitable for ABB Tmax XT2 moulded case circuit breakers
Number of poles 3P
Rated current (In) 160 A
Protection functions LSIG
Trip functions Long-time, short-time, instantaneous and ground fault
Technology Solid-state electronic release
Application AC low voltage distribution protection
Standards IEC 60947-2
Weight approx. 1 kg

Frequently Asked Questions

What is the ABB 1SDA100107R1 used for?

The ABB 1SDA100107R1 is an Ekip Touch LSIG electronic trip unit designed for ABB Tmax XT2 moulded case circuit breakers.

What protection functions does the Ekip Touch LSIG provide?

The unit provides long-time, short-time, instantaneous and ground fault (LSIG) protection functions.

What is the rated current of this ABB trip unit?

The Ekip Touch LSIG In=160A XT2 3p has a rated current of 160 A.

Which circuit breakers are compatible with this trip unit?

This electronic release is designed for use with ABB Tmax XT2 moulded case circuit breakers.

Is this a complete circuit breaker?

No, the ABB 1SDA100107R1 is an electronic protection unit designed as an accessory/component for compatible Tmax XT2 circuit breakers.

Trusted by Electrical Engineers Worldwide

ABB Ekip Touch electronic trip units provide intelligent protection, accurate adjustment and advanced monitoring capabilities for modern low voltage electrical distribution systems.