ABB 1SDA082135R1 is a 50% external neutral current sensor designed for compatible SACE Emax 2 E4.2–E6.2 air circuit breaker installations requiring external neutral-current sensing.
£1,826.33
The ABB 1SDA082135R1 is an external neutral current sensor designed for compatible ABB SACE Emax 2 air circuit breakers. Identified as Ext CS N E4.2–E6.2 50% UL, it is intended for Emax 2 E4.2 and E6.2 applications requiring measurement of neutral-conductor current outside the circuit breaker.
As part of the ABB SACE Emax 2 accessory range, the external neutral sensor interfaces with a compatible Ekip electronic trip unit so that neutral-current information can be incorporated into the breaker's protection functions. This is particularly relevant to three-pole breaker installations where the neutral conductor does not pass through the circuit breaker itself.
The 1SDA082135R1 is the 50% external-neutral sensor configuration for the E4.2–E6.2 range and is associated with ABB US/Canada part number ZE6NCT. It provides a purpose-designed ABB solution for integrating external neutral-current sensing into compatible Emax 2 low-voltage power distribution systems.
In a three-pole circuit breaker installation, the neutral conductor can remain outside the breaker's main current path. An external neutral current sensor allows a compatible Ekip trip unit to monitor current in this separate neutral conductor, enabling the protection system to account for neutral-current conditions as part of the overall electrical protection arrangement.
The ABB 1SDA082135R1 is specifically associated with Emax 2 E4.2–E6.2 applications and provides a 50% neutral sensing configuration. Correct selection and installation of the external sensor allows the Emax 2 protection system to receive the neutral-current measurement required by the configured protection scheme.
| Series | SACE Emax 2 |
|---|---|
| ABB order code | 1SDA082135R1 |
| US / Canada part number | ZE6NCT |
| Product type | External neutral current sensor |
| ABB designation | Ext CS N E4.2–E6.2 50% UL |
| Compatible breaker frames | E4.2–E6.2 |
| Neutral configuration | 50% |
| Application | External neutral-current sensing |
| Compatible breaker configuration | 3-pole |
| Compatible series | ABB SACE Emax 2 |
| Product group | Emax2 Air Circuit Breaker |
The ABB 1SDA082135R1 is an external neutral current sensor for compatible ABB SACE Emax 2 E4.2–E6.2 air circuit breaker installations.
The sensor is designed for compatible Emax 2 E4.2 and E6.2 circuit breaker applications.
Ext CS N identifies an external current sensor for the neutral conductor, allowing a compatible Ekip trip unit to receive neutral-current information when the neutral is outside the circuit breaker.
The 50% designation identifies this accessory as the 50% external-neutral current sensor configuration specified for compatible E4.2–E6.2 Emax 2 applications.
Yes. ABB specifies external neutral-current sensing for compatible three-pole circuit breaker installations where the neutral conductor is external to the breaker's main poles.
The corresponding ABB US/Canada part number is ZE6NCT.
It is typically used in ABB SACE Emax 2 low-voltage switchgear where external neutral-current sensing is required for a compatible E4.2 or E6.2 three-pole circuit breaker and Ekip protection system.
ABB SACE Emax 2 accessories are engineered to extend the protection, measurement and integration capabilities of Emax 2 air circuit breakers, providing purpose-designed components for sophisticated low-voltage power distribution systems.