1SDA081783R1 ABB E2.2/MT 2000 MP 4p Earth UP Emax 2 Air Circuit Breaker Accessory

1SDA081783R1 ABB E2.2/MT 2000 MP 4p Earth UP Emax 2 Air Circuit Breaker Accessory

ABB E2.2/MT 2000 MP 4p Earth UP Emax 2 derived earthing truck solution rated at 2000 A for safe low voltage industrial power distribution applications.

SKU: 1SDA081783R1MPN: 1SDA081783R1
Price
List Price £11,185.58 ex VAT
Your Price (ex VAT) Save 25%
£8,389.19 25% OFF
You save £2,796.40 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,389.19
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,389.19

Why Choose the ABB E2.2/MT 2000 MP 4p Earth UP?

The ABB E2.2/MT 2000 MP 4p Earth UP is a high-performance SACE Emax 2 low voltage air circuit breaker accessory solution designed for reliable earthing operations and safe isolation within advanced electrical distribution systems. As part of the ABB Emax 2 air circuit breaker family, this derived version provides robust mechanical integration for demanding industrial power applications.

Designed for use with ABB Emax 2 E2.2 circuit breaker systems, the E2.2/MT 2000 MP 4p Earth UP delivers dependable earthing functionality for maintenance and operational safety procedures. Its engineered construction supports efficient installation, improved system protection and reliable performance in industrial switchgear environments.

With a rated current capability of 2000 A, a four-pole configuration and operation up to 690 V AC, this ABB Emax 2 derived version is suitable for high-power low voltage distribution applications requiring secure earthing and switching solutions.

Key Advantages

  • Designed for ABB SACE Emax 2 E2.2 air circuit breaker systems.
  • 2000 A rated current capability for demanding power distribution applications.
  • Four-pole configuration for comprehensive circuit management.
  • Provides reliable earthing truck functionality with upper earth connection.
  • Supports safe maintenance procedures in industrial switchgear installations.
  • Built to ABB quality standards for dependable long-term operation.

Key Features

  • ABB SACE Emax 2 Air Circuit Breaker series.
  • E2.2 sub-type platform.
  • 2000 A rated uninterrupted current.
  • 690 V AC rated operational voltage.
  • 12 kV rated impulse withstand voltage.
  • 4P four-pole design.
  • Derived version: Earthing truck MT.
  • Upper earth connection arrangement.
  • IEC compliant construction.

Reliable Earthing for Industrial Power Systems

The ABB Emax 2 platform is engineered to provide advanced protection, switching and operational flexibility for modern low voltage electrical distribution networks. Accessories such as the E2.2/MT 2000 MP 4p Earth UP extend system functionality by enabling safe earthing procedures during maintenance and service operations.

By combining ABB engineering expertise with the modular Emax 2 architecture, this earthing solution helps electrical engineers and facility operators maintain safe, efficient and reliable power distribution systems across industrial environments.

Typical Applications

  • Industrial low voltage switchboards.
  • Power distribution systems.
  • Manufacturing facilities.
  • Energy infrastructure installations.
  • Large commercial electrical systems.
  • Industrial maintenance and protection applications.

Technical Specifications

Product group Emax2 Air Circuit Breaker
Series SACE Emax 2
Order code 1SDA081783R1
Product type Derived version - Earthing truck MT
Sub-type E2.2
Rated current 2000 A
Rated uninterrupted current 2000 A
Rated operational voltage 690 V AC
Rated voltage 690 V
Rated impulse withstand voltage 12 kV
Number of poles 4P
Current type AC
Neutral pole current 100 % Iu
Standards IEC
Mounting type Emax 2 compatible withdrawable system
Dimensions (H × W × D) approx. 425 × 407 × 383 mm
Weight approx. 73 kg

Frequently Asked Questions

What is the ABB E2.2/MT 2000 MP 4p Earth UP used for?

This ABB Emax 2 derived version provides earthing truck functionality for safe maintenance and operational procedures within compatible E2.2 air circuit breaker systems.

What current rating does this ABB unit support?

The E2.2/MT 2000 MP 4p Earth UP has a rated current of 2000 A.

What voltage rating does this product have?

The unit is rated for operation up to 690 V AC with a rated impulse withstand voltage of 12 kV.

Which ABB product family does this belong to?

This product belongs to the ABB SACE Emax 2 Air Circuit Breaker family.

How many poles does this ABB Emax 2 version have?

The E2.2/MT 2000 MP 4p Earth UP is a four-pole (4P) configuration.

Trusted by Industrial Power Engineers Worldwide

ABB Emax 2 systems are trusted by electrical engineers and industrial operators worldwide for reliable circuit protection, safe maintenance procedures and flexible low voltage power distribution.