1SDA074283R1 ABB 2500 A L OFF Rating Plug Emax 2 E2.2-E6.2 INST

1SDA074283R1 ABB 2500 A L OFF Rating Plug Emax 2 E2.2-E6.2 INST

ABB 1SDA074283R1 is a 2500 A L OFF installed rating plug for compatible SACE Emax 2 E2.2, E4.2 and E6.2 air circuit-breaker protection configurations.

SKU: 1SDA074283R1MPN: 1SDA074283R1
Price
List Price £42.13 ex VAT
Your Price (ex VAT) Save 25%
£31.60 25% OFF
You save £10.53 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £31.60
Trade pricing is personalised to your account

Manufacturer Lead Time

£31.60

Why Choose the ABB 1SDA074283R1 2500 A L OFF Rating Plug?

The ABB 1SDA074283R1 is a 2500 A L OFF rating plug designed for compatible ABB SACE Emax 2 air circuit breakers. Identified by ABB as RATING PLUG 2500 L OFF E2.2..E6.2 INST, it provides a 2500 A current reference for compatible Emax 2 E2.2, E4.2 and E6.2 protection configurations.

The L OFF configuration is intended for applications where the long-time overload protection function is disabled. This specialised arrangement supports engineered protection schemes in which overload protection is provided separately or where long-time protection from the circuit-breaker trip unit is intentionally not required.

The INST designation identifies this version as an installed configuration for the compatible Emax 2 circuit breaker. Combining a high 2500 A rating with ABB's modular Emax 2 protection architecture, the 1SDA074283R1 is suited to demanding low-voltage power-distribution installations.

Key Advantages

  • Genuine ABB SACE Emax 2 rating plug.
  • 2500 A rated current for high-current protection configurations.
  • L OFF configuration for applications without long-time overload protection from the trip unit.
  • Compatible with Emax 2 E2.2, E4.2 and E6.2 frames.
  • INST version for an installed circuit-breaker configuration.
  • Supports specialised protection schemes with separately implemented overload protection.

Key Features

  • ABB Emax 2 rating plug.
  • 2500 A L OFF configuration.
  • Long-time overload protection function configured as OFF.
  • Suitable for E2.2, E4.2 and E6.2 circuit-breaker frames.
  • INST installed version.
  • Part of the modular ABB Emax 2 electronic protection architecture.
  • Designed for demanding low-voltage distribution systems.
  • ABB order code 1SDA074283R1.

2500 A L OFF Protection Configuration for Emax 2

ABB rating plugs form part of the configurable electronic protection architecture used with SACE Emax 2 air circuit breakers. The rating plug establishes the applicable current reference for the compatible protection system, enabling the circuit breaker to be configured for the required installation characteristics.

The ABB 1SDA074283R1 combines a 2500 A current reference with an L OFF configuration for compatible E2.2, E4.2 and E6.2 circuit breakers. It is particularly suited to engineered systems where the long-time overload function is intentionally disabled and overload protection is addressed elsewhere in the overall electrical protection scheme.

Typical Applications

  • ABB SACE Emax 2 E2.2, E4.2 and E6.2 air circuit breakers.
  • Applications requiring a 2500 A L OFF protection configuration.
  • Systems with separately implemented overload protection.
  • Industrial low-voltage main distribution switchboards.
  • Infrastructure and critical power distribution systems.
  • OEM and factory-configured switchgear assemblies.

Technical Specifications

Series SACE Emax 2
Order code 1SDA074283R1
Product designation RATING PLUG 2500 L OFF E2.2..E6.2 INST
Product type L OFF rating plug
Rated current 2500 A
Long-time protection configuration L OFF
Compatible circuit-breaker family ABB SACE Emax 2
Compatible frames E2.2, E4.2, E6.2
Configuration INST / installed

Frequently Asked Questions

What is the ABB 1SDA074283R1?

It is a 2500 A L OFF rating plug for compatible ABB SACE Emax 2 E2.2, E4.2 and E6.2 air circuit-breaker protection configurations.

What does L OFF mean on the ABB 1SDA074283R1?

L OFF indicates that the long-time overload protection function is disabled, supporting applications where overload protection is provided separately or is not required from the compatible circuit-breaker trip unit.

What is the rated current of the ABB 1SDA074283R1?

The ABB 1SDA074283R1 provides a rated-current reference of 2500 A.

Which Emax 2 frames are compatible with ABB 1SDA074283R1?

The rating plug is specified for compatible ABB SACE Emax 2 E2.2, E4.2 and E6.2 circuit-breaker frames.

What does INST mean for ABB 1SDA074283R1?

INST identifies this product as the installed version of the 2500 A L OFF rating-plug configuration for the compatible Emax 2 circuit breaker.

Trusted by Power Distribution Professionals

ABB SACE Emax 2 circuit breakers provide a modular protection platform for demanding low-voltage distribution systems, with dedicated rating-plug configurations supporting specialised protection requirements across industrial, infrastructure and OEM switchgear.