1SDA074276R1 ABB Rating Plug 400 A L OFF E1.2..E6.2 INST

1SDA074276R1 ABB Rating Plug 400 A L OFF E1.2..E6.2 INST

ABB 1SDA074276R1 is a 400 A L OFF installation-version rating plug for compatible Ekip electronic trip units used with SACE Emax 2 E1.2 through E6.2 air circuit breakers.

SKU: 1SDA074276R1MPN: 1SDA074276R1
Price
List Price £42.13 ex VAT
Your Price (ex VAT) Save 25%
£31.60 25% OFF
You save £10.53 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £31.60
Trade pricing is personalised to your account

Manufacturer Lead Time

£31.60

Why Choose the ABB 1SDA074276R1 400 A L OFF Rating Plug?

The ABB 1SDA074276R1 is a genuine 400 A L OFF rating plug designed for compatible ABB SACE Emax 2 air circuit breakers and Ekip electronic trip units. Identified by ABB as RATING PLUG 400 L OFF E1.2..E6.2 INST, this version provides a 400 A current reference with the long-time overload protection function disabled and is intended for installation in compatible Emax 2 E1.2 through E6.2 configurations.

Rating plugs are an integral part of the ABB Ekip protection architecture, establishing the rated-current reference used by the electronic trip unit. The L OFF configuration is specifically intended for applications where long-time overload protection is not required, allowing compatible Ekip protection functions to be configured around the selected 400 A current reference.

The INST designation identifies this product as the installation version of the rating plug. Designed for the E1.2, E2.2, E4.2 and E6.2 Emax 2 frame range, the 1SDA074276R1 provides a dedicated ABB component for specialised low-voltage circuit-breaker configurations.

Key Advantages

  • Genuine ABB SACE Emax 2 rating plug for compatible Ekip electronic trip units.
  • Provides a 400 A rated-current reference for protection-system configuration.
  • L OFF configuration for applications requiring long-time overload protection to be disabled.
  • Suitable for E1.2, E2.2, E4.2 and E6.2 Emax 2 circuit-breaker frames.
  • INST version intended for installation in compatible circuit-breaker configurations.
  • Designed specifically for integration with the ABB Ekip electronic protection platform.

Key Features

  • ABB Emax 2 rating plug.
  • 400 A current rating.
  • L OFF protection configuration.
  • Long-time overload protection function disabled.
  • INST installation version.
  • Designed for compatible Ekip electronic trip units.
  • Compatible with Emax 2 E1.2 through E6.2 frame sizes.
  • Dedicated ABB accessory for low-voltage air circuit-breaker protection systems.

Specialised Current Referencing for Emax 2 Protection

The rating plug establishes the current reference used by a compatible Ekip electronic trip unit when applying its protection settings. The ABB 1SDA074276R1 provides a 400 A reference while its L OFF configuration disables the long-time overload protection function for applications where that protection characteristic is intentionally excluded.

As a dedicated installation component within the ABB SACE Emax 2 protection architecture, the 1SDA074276R1 is intended for compatible E1.2 through E6.2 circuit breakers requiring a 400 A L OFF configuration. Selecting the correct rating plug ensures that the Ekip protection system is configured for the intended breaker and application.

Typical Applications

  • ABB SACE Emax 2 E1.2 air circuit breakers.
  • ABB SACE Emax 2 E2.2, E4.2 and E6.2 air circuit breakers.
  • Ekip electronic trip-unit configuration.
  • Applications requiring a 400 A current reference with long-time protection disabled.
  • Industrial low-voltage switchboards and distribution panels.
  • Main incoming and feeder circuit-breaker assemblies.
  • Commercial and infrastructure power distribution systems.

Technical Specifications

Series SACE Emax 2
ABB order code 1SDA074276R1
Product type Rating plug for Ekip electronic trip units
Rated current 400 A
Protection configuration L OFF
Long-time protection Disabled
Version INST installation version
Compatible frame sizes E1.2, E2.2, E4.2 and E6.2
Suitable for ABB SACE Emax 2 air circuit breakers
Product group Emax2 Air Circuit Breaker

Frequently Asked Questions

What is the ABB 1SDA074276R1?

The ABB 1SDA074276R1 is a 400 A L OFF rating plug installation version for compatible Ekip electronic trip units used with ABB SACE Emax 2 E1.2 through E6.2 air circuit breakers.

What is the current rating of the ABB 1SDA074276R1?

The rating plug provides a rated-current reference of 400 A.

What does L OFF mean on this ABB rating plug?

L OFF indicates a configuration in which the long-time overload protection function is disabled.

Which Emax 2 frame sizes are compatible with the 1SDA074276R1?

The 1SDA074276R1 is identified for ABB SACE Emax 2 E1.2, E2.2, E4.2 and E6.2 frame sizes.

What does INST indicate on the 1SDA074276R1?

INST identifies this part as the installation version of the 400 A L OFF rating plug for compatible ABB Emax 2 configurations.

Trusted ABB Protection for Power Distribution

ABB SACE Emax 2 circuit breakers and Ekip electronic protection units use dedicated rating plugs to provide flexible current and protection configurations for demanding industrial, commercial and infrastructure low-voltage distribution systems.