1SDA073742R1 ABB Toroid RC E2.2 4p, E4.2 for Differential Protection

1SDA073742R1 ABB Toroid RC E2.2 4p, E4.2 for Differential Protection

ABB 1SDA073742R1 is an RC toroid designed to provide residual-current sensing for differential and earth leakage protection with compatible ABB Emax 2 E2.2 4-pole and E4.2 air circuit breakers.

SKU: 1SDA073742R1MPN: 1SDA073742R1
Price
List Price £2,493.82 ex VAT
Your Price (ex VAT) Save 25%
£1,870.37 25% OFF
You save £623.46 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,870.37
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,870.37

Why Choose the ABB 1SDA073742R1 Toroid RC for Differential Protection?

The ABB 1SDA073742R1 is a dedicated RC toroid for differential and residual-current protection designed for compatible ABB Emax 2 air circuit breakers. It provides the external residual-current sensing required by an appropriately configured Emax 2 protection system, helping detect earth leakage faults in low-voltage power distribution installations.

Designed for ABB Emax 2 E2.2 4-pole and E4.2 circuit breakers, the 1SDA073742R1 forms part of ABB's residual-current protection accessory range. The toroid monitors the conductors passing through it and provides a sensing signal to the associated protection system when a residual-current imbalance occurs.

ABB specifies the 1SDA073742R1 as Toroid RC E2.2 4p, E4.2. In an appropriate Emax 2 residual-current protection arrangement, the external toroid supports earth leakage protection over the 3–30 A range and is supplied as a loose accessory for integration into the switchgear installation.

Key Advantages

  • Dedicated RC toroid for differential and residual-current protection.
  • Designed for ABB Emax 2 E2.2 4-pole and E4.2 circuit breakers.
  • Provides external residual-current sensing for compatible Emax 2 protection systems.
  • Supports earth leakage protection in the 3–30 A range when used in the appropriate ABB protection configuration.
  • Suitable for industrial low-voltage switchboards and power distribution systems.
  • Purpose-designed ABB accessory for coordinated integration with the Emax 2 platform.

Key Features

  • ABB Emax 2 RC toroid.
  • Designed for differential / residual-current protection.
  • Compatible with Emax 2 E2.2 4-pole circuit breakers.
  • Compatible with Emax 2 E4.2 applications.
  • External toroidal sensor for detecting residual-current imbalance.
  • Used as part of an appropriately configured Emax 2 residual-current protection system.
  • Supplied as a loose part.
  • ABB order code 1SDA073742R1.

Residual-Current Sensing for Emax 2 Protection Systems

A residual-current toroid monitors the conductors passing through its aperture and detects an imbalance between their currents. Under normal operating conditions the vector sum of the currents is balanced; leakage current flowing outside the intended circuit path produces a residual signal that can be evaluated by the associated circuit breaker protection system.

For compatible ABB Emax 2 installations, the 1SDA073742R1 acts as the external toroid in a residual-current protection arrangement. ABB's Emax 2 system can provide earth leakage protection over the 3–30 A range when the required residual-current plug, external toroid, Ekip Supply and measurement-enabling components are combined with a compatible Ekip Touch LSIG trip unit.

Typical Applications

  • ABB Emax 2 E2.2 4-pole air circuit breaker installations.
  • ABB Emax 2 E4.2 air circuit breaker installations.
  • Residual-current and differential protection systems.
  • Industrial low-voltage switchboards.
  • Power distribution and protection panels.
  • Electrical installations requiring earth leakage monitoring and protection.

Technical Specifications

Series Emax 2
Order code 1SDA073742R1
Product type Residual-current / differential protection toroid
Accessory designation Toroid RC
Protection function Differential / residual-current protection
Residual-current protection range 3–30 A when used in the appropriate Emax 2 protection configuration
Compatible breaker frame E2.2 4-pole
Compatible series ABB Emax 2 Air Circuit Breakers
Installation External toroid / loose accessory
Application standard IEC
Function Residual-current sensing for differential protection
ABB product group Emax2 Air Circuit Breaker

Frequently Asked Questions

What is the ABB 1SDA073742R1 used for?

The ABB 1SDA073742R1 is an RC toroid used to provide residual-current sensing for differential and earth leakage protection in compatible ABB Emax 2 circuit breaker installations.

Which ABB circuit breakers are compatible with the 1SDA073742R1?

The 1SDA073742R1 is specified for ABB Emax 2 E2.2 4-pole and E4.2 circuit breaker applications.

What protection function does the ABB 1SDA073742R1 support?

It supports differential and residual-current protection by providing the external current sensing required by an appropriately configured Emax 2 protection system.

What residual-current protection range can an Emax 2 system provide with an RC toroid?

ABB specifies residual-current earth leakage protection over a 3–30 A range for appropriately configured Emax 2 E1.2, E2.2 and E4.2 systems using the required residual-current protection accessories.

Is the ABB 1SDA073742R1 supplied as a separate accessory?

Yes. ABB specifies the 1SDA073742R1 RC toroid as a loose part for integration into compatible Emax 2 residual-current protection systems.

Trusted by Electrical and Switchgear Professionals Worldwide

ABB Emax 2 air circuit breakers and their dedicated protection accessories provide an integrated platform for low-voltage power distribution, helping switchboard builders and electrical engineers implement dependable circuit protection, residual-current monitoring and coordinated power system control.