1SDA069599R1 ABB Ekip E-LSIG 160 A XT4 4-Pole Electronic Trip Unit

1SDA069599R1 ABB Ekip E-LSIG 160 A XT4 4-Pole Electronic Trip Unit

ABB 1SDA069599R1 is a 160 A four-pole Ekip E-LSIG solid-state electronic trip unit providing long-time, short-time, instantaneous and earth-fault protection for compatible SACE Tmax XT4 circuit breakers.

SKU: 1SDA069599R1MPN: 1SDA069599R1
Price
List Price £1,423.39 ex VAT
Your Price (ex VAT) Save 25%
£1,067.54 25% OFF
You save £355.85 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,067.54
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,067.54

Why Choose the ABB Ekip E-LSIG In=160A XT4 4p Trip Unit?

The ABB Ekip E-LSIG In=160A XT4 4p, order code 1SDA069599R1, is a four-pole solid-state electronic trip unit designed for compatible ABB SACE Tmax XT4 moulded case circuit breakers. Rated at 160 A, it provides advanced electronic protection for low-voltage AC distribution systems.

The Ekip E-LSIG release provides long-time (L), short-time (S), instantaneous (I) and earth-fault (G) protection functions. This comprehensive LSIG protection package enables the associated XT4 circuit breaker to protect conductors and equipment against overloads, delayed short circuits, severe instantaneous faults and earth-fault conditions.

Designed specifically for a four-pole XT4 configuration, the 1SDA069599R1 is supplied as a separate electronic protection release for integration with a compatible Tmax XT4 breaking part. Its electronic architecture provides greater protection functionality than basic thermomagnetic releases while retaining the compact format of the Tmax XT platform.

Key Advantages

  • Genuine ABB SACE Tmax XT4 electronic trip unit.
  • 160 A rated current.
  • Four-pole configuration for compatible XT4 circuit breakers.
  • Comprehensive LSIG protection functions.
  • Long-time protection for sustained overload conditions.
  • Short-time and instantaneous protection for short-circuit faults.
  • Integrated earth-fault protection.
  • Solid-state electronic technology for precise circuit protection.

Key Features

  • Ekip E-LSIG electronic release.
  • 160 A rated current.
  • 4-pole configuration.
  • Designed for ABB SACE Tmax XT4.
  • L – Long-time overload protection.
  • S – Short-time short-circuit protection.
  • I – Instantaneous short-circuit protection.
  • G – Earth-fault protection.
  • Solid-state electronic trip technology.
  • Designed for low-voltage AC circuit breaker applications.
  • Suitable for compatible ABB XT4 moulded case circuit breaker assemblies.

Comprehensive Electronic LSIG Protection

The Ekip E-LSIG release combines four essential protection functions in one electronic trip unit. Long-time protection responds to sustained overloads, while short-time protection provides controlled response to short-circuit currents. Instantaneous protection enables rapid operation during severe faults, and the G function adds dedicated earth-fault protection.

With a rated current of 160 A and a four-pole configuration, the 1SDA069599R1 provides a comprehensive protection solution for compatible XT4 circuit breaker assemblies. Its electronic design makes it well suited to distribution systems requiring more sophisticated fault protection than a conventional fixed thermomagnetic release can provide.

Typical Applications

  • Industrial low-voltage distribution systems.
  • Commercial electrical switchboards.
  • Four-pole feeder protection.
  • Three-phase and neutral distribution circuits.
  • Industrial machinery and equipment panels.
  • Electrical systems requiring earth-fault protection.
  • OEM switchgear assemblies.
  • Compatible ABB SACE Tmax XT4 circuit breakers.

Technical Specifications

Series SACE Tmax XT
Product group T-Max XT 250 Range
Product designation Ekip E-LSIG In=160A XT4 4p
ABB order code 1SDA069599R1
EAN 8015644703530
Product type Electronic circuit breaker trip unit
Release Ekip E-LSIG
Release technology Solid-state electronic
Rated current 160 A
Number of poles 4
Protection functions L, S, I, G
Long-time protection Overload
Short-time protection Delayed short circuit
Instantaneous protection Short circuit
Earth-fault protection Yes
Undelayed short-circuit release setting range 160–1600 A
Suitable for ABB SACE Tmax XT4
Application Low-voltage AC circuit protection

Frequently Asked Questions

What is the ABB 1SDA069599R1?

The ABB 1SDA069599R1 is a 160 A four-pole Ekip E-LSIG solid-state electronic trip unit designed for compatible ABB SACE Tmax XT4 moulded case circuit breakers.

What protection functions does the ABB Ekip E-LSIG provide?

The Ekip E-LSIG provides long-time (L), short-time (S), instantaneous (I) and earth-fault (G) protection.

What is the rated current of the ABB 1SDA069599R1?

The Ekip E-LSIG trip unit has a rated current of 160 A.

How many poles does the ABB 1SDA069599R1 support?

The 1SDA069599R1 is the four-pole version of the 160 A Ekip E-LSIG trip unit for the Tmax XT4 platform.

Is the ABB 1SDA069599R1 a complete circuit breaker?

No. The 1SDA069599R1 is an electronic protection trip unit designed to be combined with a compatible ABB SACE Tmax XT4 breaking part to create the required circuit breaker assembly.

Trusted ABB Electronic Circuit Protection

ABB SACE Tmax XT electronic trip units provide advanced overload, short-circuit and earth-fault protection for modern low-voltage distribution systems, supporting dependable and configurable circuit breaker assemblies across industrial and commercial applications.