1SDA069066R1 ABB UVR-C XT2-XT4 W 48 V AC/DC Undervoltage Release

1SDA069066R1 ABB UVR-C XT2-XT4 W 48 V AC/DC Undervoltage Release

ABB 1SDA069066R1 is a 48 V AC/DC cabled undervoltage release designed for compatible withdrawable SACE Tmax XT2 and XT4 moulded case circuit breakers.

SKU: 1SDA069066R1MPN: 1SDA069066R1
Price
List Price £164.07 ex VAT
Your Price (ex VAT) Save 25%
£123.05 25% OFF
You save £41.02 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £123.05
Trade pricing is personalised to your account

Manufacturer Lead Time

£123.05

Why Choose the ABB UVR-C XT2-XT4 W 48 Vac/dc?

The ABB UVR-C XT2-XT4 W 48 Vac/dc, order code 1SDA069066R1, is a cabled undervoltage release designed for withdrawable ABB SACE Tmax XT2 and XT4 moulded case circuit breakers. Operating from a 48 V AC/DC control supply, it provides an automatic circuit breaker release function when the auxiliary voltage falls below the required operating level.

The UVR-C is the wired version of ABB's undervoltage release. When correctly energised, it permits normal operation of the compatible breaker mechanism. If the auxiliary supply is removed or drops sufficiently, the release trips the circuit breaker and prevents it from being closed while the undervoltage condition remains.

This specific version is engineered for withdrawable (W) XT2 and XT4 circuit breakers, distinguishing it from the UVR-C accessories intended for fixed and plug-in installations. Its 48 V AC/DC rating makes it suitable for industrial control circuits using either AC or DC auxiliary power.

Key Advantages

  • Genuine ABB SACE Tmax XT undervoltage release.
  • 48 V AC/DC control voltage for AC or DC auxiliary systems.
  • Cabled UVR-C version for convenient integration.
  • Designed specifically for withdrawable XT2 and XT4 circuit breakers.
  • Automatically releases the breaker following sufficient loss of auxiliary voltage.
  • Prevents normal breaker closing while the undervoltage release is de-energised.
  • Supports electrical control, interlocking and safety functions.
  • Compliant with applicable IEC 60947-2 and UL 489 requirements.

Key Features

  • UVR-C cabled undervoltage release.
  • 48 V AC rated control voltage.
  • 48 V DC rated control voltage.
  • Compatible with ABB SACE Tmax XT2 and XT4.
  • Designed for withdrawable (W) circuit breakers.
  • AC/DC operating capability.
  • Automatic response to loss or significant reduction of control voltage.
  • Suitable for circuit breaker control and interlocking schemes.
  • Loose/configurable ABB Tmax XT accessory.

Undervoltage Protection for Withdrawable XT Breakers

An undervoltage release is used when a circuit breaker must open automatically following loss or excessive reduction of its auxiliary control voltage. This can be important in machinery, process equipment and distribution systems where equipment should not remain energised or restart unexpectedly following a control-power failure.

The ABB 1SDA069066R1 combines this functionality with a 48 V AC/DC cabled design specifically for withdrawable XT2 and XT4 circuit breakers. The withdrawable-specific construction ensures compatibility with the corresponding breaker arrangement while providing ABB-engineered control functionality within the Tmax XT platform.

Typical Applications

  • Industrial low-voltage switchboards.
  • Withdrawable ABB Tmax XT2 circuit breaker installations.
  • Withdrawable ABB Tmax XT4 circuit breaker installations.
  • Machine control and automation panels.
  • Motor control and distribution systems.
  • Control-power loss protection circuits.
  • Electrical interlocking schemes.
  • OEM switchgear and industrial equipment.

Technical Specifications

Series SACE Tmax XT
Product group T-Max XT 250 Range
Product designation UVR-C XT2-XT4 W 48 Vac/dc
ABB order code 1SDA069066R1
EAN 8015644697624
Product type Undervoltage release
Release designation UVR-C
Version Cabled
Rated control voltage AC 48 V AC
Rated control voltage DC 48 V DC
Current type AC/DC
Compatible frames XT2, XT4
Compatible breaker version Withdrawable (W)
Configuration Loose / configurable
Function Undervoltage circuit breaker release
Standards IEC 60947-2, UL 489
Net weight 0.123 kg

Frequently Asked Questions

What is the ABB 1SDA069066R1?

The ABB 1SDA069066R1 is a 48 V AC/DC cabled undervoltage release designed for compatible withdrawable ABB SACE Tmax XT2 and XT4 moulded case circuit breakers.

What voltage does the ABB 1SDA069066R1 require?

The UVR-C is rated for a 48 V AC or 48 V DC auxiliary control supply.

Which circuit breakers are compatible with the ABB 1SDA069066R1?

The 1SDA069066R1 is designed for compatible ABB SACE Tmax XT2 and XT4 withdrawable circuit breakers.

What does the W designation mean on the UVR-C XT2-XT4 W?

The W designation means withdrawable, indicating that this UVR-C version is specifically designed for the withdrawable configurations of compatible XT2 and XT4 circuit breakers.

What does the ABB UVR-C undervoltage release do?

The UVR-C causes the compatible circuit breaker to release when its control voltage falls sufficiently or is removed and prevents normal closing while the undervoltage release remains de-energised.

Trusted ABB Circuit Breaker Accessories

ABB SACE Tmax XT control accessories provide purpose-designed solutions for circuit breaker automation, interlocking and protection, supporting dependable operation in industrial, commercial and OEM low-voltage electrical systems.