1SDA068203R1 ABB XT2 W FP 4p HR Withdrawable Circuit Breaker Fixed Part

1SDA068203R1 ABB XT2 W FP 4p HR Withdrawable Circuit Breaker Fixed Part

ABB 1SDA068203R1 XT2 W FP 4p HR is a 160 A four-pole fixed part for withdrawable SACE Tmax XT2 circuit breakers with horizontal rear terminals and rated operational voltage up to 690 V AC or 500 V DC.

SKU: 1SDA068203R1MPN: 1SDA068203R1
Price
List Price £719.87 ex VAT
Your Price (ex VAT) Save 25%
£539.90 25% OFF
You save £179.97 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £539.90
Trade pricing is personalised to your account

Manufacturer Lead Time

£539.90

Why Choose the ABB XT2 W FP 4p HR Fixed Part?

The ABB 1SDA068203R1 XT2 W FP 4p HR is a four-pole fixed part for withdrawable ABB SACE Tmax XT2 moulded case circuit breakers. Designed as the stationary section of an XT2 withdrawable installation, it provides the permanent electrical and mechanical interface required for a compatible withdrawable breaker assembly while supporting convenient removal for inspection, servicing or replacement.

Rated for an uninterrupted current of 160 A, the fixed part supports rated operational voltages up to 690 V AC and 500 V DC. The HR configuration uses horizontal rear terminals, enabling the main circuit connections to be routed behind the breaker assembly and helping create an organised switchboard layout with permanent fixed-side connections.

The withdrawable arrangement enables a suitably configured XT2 moving part to be withdrawn from the fixed section without dismantling the permanent main-circuit connections. With its four-pole configuration, 1000 V insulation voltage and 8 kV impulse withstand voltage, the 1SDA068203R1 provides a robust connection platform for three-phase and neutral industrial and commercial distribution systems.

Key Advantages

  • Genuine ABB SACE Tmax XT2 withdrawable fixed part.
  • 160 A rated uninterrupted current for compatible XT2 installations.
  • Four-pole configuration for three-phase and neutral electrical systems.
  • Horizontal rear terminals support convenient rear conductor or busbar connection.
  • Withdrawable construction supports efficient circuit breaker servicing, replacement and maintenance.
  • Permanent fixed-side electrical connections can remain installed when the compatible moving part is withdrawn.
  • Supports operating voltages up to 690 V AC and 500 V DC.
  • Modular ABB Tmax XT construction supports flexible low-voltage switchboard design.

Key Features

  • ABB SACE Tmax XT2 accessory.
  • XT2 W FP 4p HR configuration.
  • W: withdrawable execution.
  • FP: fixed part.
  • 4p: four-pole configuration.
  • HR: horizontal rear terminals.
  • 160 A rated uninterrupted current.
  • 690 V AC / 500 V DC rated operational voltage.
  • 1000 V rated insulation voltage.
  • 8 kV rated impulse withstand voltage.
  • 50 / 60 Hz rated frequency.
  • Designed for compatible withdrawable ABB Tmax XT2 circuit breaker assemblies.

Flexible Withdrawable Connection for Tmax XT2 Circuit Breakers

The ABB XT2 W FP fixed part forms the stationary section of a withdrawable Tmax XT2 circuit breaker installation. Once mounted and connected within the switchboard, it provides the fixed interface required for the compatible withdrawable breaker assembly. This arrangement is particularly useful where maintainability and rapid replacement are important because permanent switchboard-side connections do not need to be dismantled each time the compatible breaker moving part is removed.

The HR horizontal rear terminal arrangement directs the main electrical connections towards the rear of the assembly, making the 1SDA068203R1 suitable for switchboards using rear busbars or conductors. The fixed part itself does not provide overcurrent protection; protection and short-circuit interruption characteristics depend on the compatible ABB SACE Tmax XT2 breaker and trip unit incorporated into the completed assembly.

Typical Applications

  • ABB Tmax XT2 withdrawable circuit breaker assemblies.
  • Industrial low-voltage switchboards.
  • Main and sub-distribution panels.
  • Three-phase and neutral electrical distribution systems.
  • Manufacturing and production facilities.
  • Commercial electrical distribution boards.
  • Machinery and automation power distribution.
  • Switchboards requiring removable breakers with permanent fixed-side connections.

Technical Specifications

Series SACE Tmax XT
ABB product group T-Max XT 250 Range
Order code 1SDA068203R1
Alternate catalogue number KXT2EWFPHR-4
Product type Fixed part for withdrawable circuit breaker
Product main type Accessory for Tmax XT
Compatible breaker platform ABB SACE Tmax XT2
Frame size XT2
Execution Withdrawable (W)
Configuration Fixed part (FP)
Rated uninterrupted current (Iu) 160 A
Rated operational voltage 690 V AC / 500 V DC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Rated frequency 50 / 60 Hz
Number of poles 4
Terminal arrangement Horizontal rear terminals
Terminal designation HR
Configuration type Loose / configurable
Standard IEC 60947-2
Net weight approx. 1.7 kg
EAN / GTIN 8015644696320

Frequently Asked Questions

What is the ABB 1SDA068203R1?

The ABB 1SDA068203R1 is a 160 A four-pole fixed part for withdrawable ABB SACE Tmax XT2 circuit breakers, equipped with horizontal rear terminals for permanent switchboard-side connections.

What does XT2 W FP 4p HR mean?

XT2 identifies the Tmax XT2 breaker platform, W denotes withdrawable execution, FP identifies the fixed part, 4p means four poles and HR denotes horizontal rear terminals.

What is the current rating of the ABB 1SDA068203R1?

The fixed part has a rated uninterrupted current of 160 A and is designed for compatible ABB SACE Tmax XT2 withdrawable circuit breaker configurations.

What voltage can the ABB XT2 W FP 4p HR support?

The 1SDA068203R1 has a rated operational voltage of up to 690 V AC or 500 V DC, with a rated insulation voltage of 1000 V and a rated impulse withstand voltage of 8 kV.

Is the ABB 1SDA068203R1 a complete circuit breaker?

No. The 1SDA068203R1 is the fixed part of a withdrawable Tmax XT2 circuit breaker installation. A compatible XT2 withdrawable breaker assembly is required to provide the switching and protection functions of the completed installation.

Trusted ABB Connectivity for Withdrawable Tmax XT2 Installations

ABB SACE Tmax XT withdrawable accessories provide flexible connection solutions for industrial and commercial switchboards, with the XT2 W FP 4p HR fixed part offering a 160 A four-pole interface, horizontal rear terminals and dependable integration with compatible withdrawable Tmax XT2 circuit breakers.